{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1199932704"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1199932704","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"DEVELOPMENT OF PARACEST MRI TO DETECT CANCER BIOMARKERS","abstract":"Molecular imaging has become one of the most significant developments in MRI in the last decade with dramatic impacts for disease diagnosis and therapy. A novel MRI contrast strategy named <i>PARAmagnetic Chemical Exchange Saturation Transfer</i>(PARACEST) can exploit the NMR chemical shift to selectively detect molecular biomarkers, while retaining the sensitivity and spatial resolution of MRI. The development of this novel approach for cancer biomarker detection is described in the following chapters. Chapter 1: Background information is presented about the relevance of biomarker detection by molecular imaging and MRI molecular imaging. The mechanisms of MRI contrast agent including T <sub>1</sub>contrast agents, T <sub>2</sub>/T <sub>2</sub>* contrast agents and CEST/PARACEST contrast agents are introduced. The PARACEST contrast mechanism is then emphasized for the potential biomedical applications. Chapter 2: A new irreversible nitric oxide (NO) responsive PARACEST MRI contrast agent, Yb-DO3oAA, has been designed, synthesized and characterized. The PARACEST effects have been investigated with respect to pH, temperature, and concentration for the <i>in vivo</i>applicability. The ability to detect NO has been demonstrated <i>in vitro</i>. Chapter 3: A new MRI method has been developed for assessing in vivo pH by using a PARACEST MRI contrast agent Yb-DO3AoAA. A ratiometric approach has been employed based on the two intra-molecular PARACEST signals. Our study has demonstrated that this method can be used for measuring extracellular pH within in vivo animal models without the need for a second “control” agent. Chapter 4: New MRI pulse sequences have been developed to address the poor temporal resolution challenges for the <i>in vivo</i>applications of PARACEST agents. Different strategies have been developed for the applications in different in vivo environments. These new MRI methods have been developed for high field small animal studies and tested both within <i>in vitro</i>and <i>in vivo</i>models. Chapter 5: The major drawbacks and technical hurdles in PARACEST studies are presented and followed by the discussion of future developments. A number of potential projects thereby are proposed as future studies.","abstract_html":"Molecular imaging has become one of the most significant developments in MRI in the last decade with dramatic impacts for disease diagnosis and therapy. A novel MRI contrast strategy named &lt;i&gt;PARAmagnetic Chemical Exchange Saturation Transfer&lt;/i&gt;(PARACEST) can exploit the NMR chemical shift to selectively detect molecular biomarkers, while retaining the sensitivity and spatial resolution of MRI. The development of this novel approach for cancer biomarker detection is described in the following chapters. Chapter 1: Background information is presented about the relevance of biomarker detection by molecular imaging and MRI molecular imaging. The mechanisms of MRI contrast agent including T &lt;sub&gt;1&lt;/sub&gt;contrast agents, T &lt;sub&gt;2&lt;/sub&gt;/T &lt;sub&gt;2&lt;/sub&gt;* contrast agents and CEST/PARACEST contrast agents are introduced. The PARACEST contrast mechanism is then emphasized for the potential biomedical applications. Chapter 2: A new irreversible nitric oxide (NO) responsive PARACEST MRI contrast agent, Yb-DO3oAA, has been designed, synthesized and characterized. The PARACEST effects have been investigated with respect to pH, temperature, and concentration for the &lt;i&gt;in vivo&lt;/i&gt;applicability. The ability to detect NO has been demonstrated &lt;i&gt;in vitro&lt;/i&gt;. Chapter 3: A new MRI method has been developed for assessing in vivo pH by using a PARACEST MRI contrast agent Yb-DO3AoAA. A ratiometric approach has been employed based on the two intra-molecular PARACEST signals. Our study has demonstrated that this method can be used for measuring extracellular pH within in vivo animal models without the need for a second “control” agent. Chapter 4: New MRI pulse sequences have been developed to address the poor temporal resolution challenges for the &lt;i&gt;in vivo&lt;/i&gt;applications of PARACEST agents. Different strategies have been developed for the applications in different in vivo environments. These new MRI methods have been developed for high field small animal studies and tested both within &lt;i&gt;in vitro&lt;/i&gt;and &lt;i&gt;in vivo&lt;/i&gt;models. Chapter 5: The major drawbacks and technical hurdles in PARACEST studies are presented and followed by the discussion of future developments. A number of potential projects thereby are proposed as future studies.","abstract_has_math":false,"creators":["Liu, Guanshu"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Pagel, Mark"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-01-10","date_published":"2008-01-10","updated_at":"2026-11-26T03:17:30Z","subjects":["Engineering, Biomedical","MRI","molecular imaging","contrast agent","PARACEST","cancer biomarker"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1199932704","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1199932704","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1199932704","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1199932704","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Pagel, Mark"]},{"key":"dc:creator","label":"Author","values":["Liu, Guanshu"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-01-10"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Biomedical","MRI","molecular imaging","contrast agent","PARACEST","cancer biomarker"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1199932704"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Molecular imaging has become one of the most significant developments in MRI in the last decade with dramatic impacts for disease diagnosis and therapy. A novel MRI contrast strategy named <i>PARAmagnetic Chemical Exchange Saturation Transfer</i>(PARACEST) can exploit the NMR chemical shift to selectively detect molecular biomarkers, while retaining the sensitivity and spatial resolution of MRI. The development of this novel approach for cancer biomarker detection is described in the following chapters. Chapter 1: Background information is presented about the relevance of biomarker detection by molecular imaging and MRI molecular imaging. The mechanisms of MRI contrast agent including T <sub>1</sub>contrast agents, T <sub>2</sub>/T <sub>2</sub>* contrast agents and CEST/PARACEST contrast agents are introduced. The PARACEST contrast mechanism is then emphasized for the potential biomedical applications. Chapter 2: A new irreversible nitric oxide (NO) responsive PARACEST MRI contrast agent, Yb-DO3oAA, has been designed, synthesized and characterized. The PARACEST effects have been investigated with respect to pH, temperature, and concentration for the <i>in vivo</i>applicability. The ability to detect NO has been demonstrated <i>in vitro</i>. Chapter 3: A new MRI method has been developed for assessing in vivo pH by using a PARACEST MRI contrast agent Yb-DO3AoAA. A ratiometric approach has been employed based on the two intra-molecular PARACEST signals. Our study has demonstrated that this method can be used for measuring extracellular pH within in vivo animal models without the need for a second “control” agent. Chapter 4: New MRI pulse sequences have been developed to address the poor temporal resolution challenges for the <i>in vivo</i>applications of PARACEST agents. Different strategies have been developed for the applications in different in vivo environments. These new MRI methods have been developed for high field small animal studies and tested both within <i>in vitro</i>and <i>in vivo</i>models. Chapter 5: The major drawbacks and technical hurdles in PARACEST studies are presented and followed by the discussion of future developments. A number of potential projects thereby are proposed as future studies."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.192","2.34 MB"]},{"key":"dc:title","label":"Title","values":["DEVELOPMENT OF PARACEST MRI TO DETECT CANCER BIOMARKERS"]}]}],"canonical_facts":{"dc:contributor":["Pagel, Mark"],"dc:creator":["Liu, Guanshu"],"dc:date":["2008-01-10"],"dc:description":["Molecular imaging has become one of the most significant developments in MRI in the last decade with dramatic impacts for disease diagnosis and therapy. A novel MRI contrast strategy named <i>PARAmagnetic Chemical Exchange Saturation Transfer</i>(PARACEST) can exploit the NMR chemical shift to selectively detect molecular biomarkers, while retaining the sensitivity and spatial resolution of MRI. The development of this novel approach for cancer biomarker detection is described in the following chapters. Chapter 1: Background information is presented about the relevance of biomarker detection by molecular imaging and MRI molecular imaging. The mechanisms of MRI contrast agent including T <sub>1</sub>contrast agents, T <sub>2</sub>/T <sub>2</sub>* contrast agents and CEST/PARACEST contrast agents are introduced. The PARACEST contrast mechanism is then emphasized for the potential biomedical applications. Chapter 2: A new irreversible nitric oxide (NO) responsive PARACEST MRI contrast agent, Yb-DO3oAA, has been designed, synthesized and characterized. The PARACEST effects have been investigated with respect to pH, temperature, and concentration for the <i>in vivo</i>applicability. The ability to detect NO has been demonstrated <i>in vitro</i>. Chapter 3: A new MRI method has been developed for assessing in vivo pH by using a PARACEST MRI contrast agent Yb-DO3AoAA. A ratiometric approach has been employed based on the two intra-molecular PARACEST signals. Our study has demonstrated that this method can be used for measuring extracellular pH within in vivo animal models without the need for a second “control” agent. Chapter 4: New MRI pulse sequences have been developed to address the poor temporal resolution challenges for the <i>in vivo</i>applications of PARACEST agents. Different strategies have been developed for the applications in different in vivo environments. These new MRI methods have been developed for high field small animal studies and tested both within <i>in vitro</i>and <i>in vivo</i>models. Chapter 5: The major drawbacks and technical hurdles in PARACEST studies are presented and followed by the discussion of future developments. A number of potential projects thereby are proposed as future studies."],"dc:format":["application/pdf","p.192","2.34 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1199932704"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Biomedical","MRI","molecular imaging","contrast agent","PARACEST","cancer biomarker"],"dc:title":["DEVELOPMENT OF PARACEST MRI TO DETECT CANCER BIOMARKERS"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:17:30Z"}