{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1206994969"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1206994969","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Feedback Control of a High Level Upper Extremity Neuroprosthesis","abstract":"The main focus of this study is controller design using a model-based approach, and implementation in a high level upper extremity neuroprosthesis. This is a system that aims to restore upper limb motor function to individuals who have suffered a spinal cord injury at the highest cervical level (C1-C4), and thus have lost voluntary control of most of the shoulder and arm muscles. To determine the optimal electrode set for this system, given the limited number of available stimulating channels, a musculoskeletal model of the upper extremity was used to run a large number of simulations and evaluate all the candidate electrode sets. The model was customized to represent a tetraplegic subject with an FES system, and the optimal electrode set was the one that allowed the model to successfully perform the largest number of movements. Subsequently, a combined feedforward-feedback controller approach was developed and tested first in a simplified arm model with six muscles and two degrees of freedom. In spite of its small scale, the model included an accurate muscle model, redundancy in the number of muscles, and kinematic coupling. It demonstrated the excellent trajectory tracking performance of the controller, even in the presence of considerable muscle fatigue and external forces. Next, the same design, augmented by a controller for shoulder stability was tested in a large-scale arm model with 22 muscles and five degrees of freedom, including a complete glenohumeral joint. In addition to its tracking ability, this controller was able to ensure shoulder stability in all cases of external disturbances. Finally, the controller was implemented in one subject with high level tetraplegia, and an adaptation method was developed to adjust the controller parameters according to the characteristics of the specific individual. In order to handle the redundancy of the upper limb, adaptation was performed using co-contraction of antagonistic muscles, and activation patterns among shoulder stabilizing and moving muscles. When tested in the shoulder and elbow of the subject, the controller achieved adaptation and allowed the execution of the desired movements.","abstract_html":"The main focus of this study is controller design using a model-based approach, and implementation in a high level upper extremity neuroprosthesis. This is a system that aims to restore upper limb motor function to individuals who have suffered a spinal cord injury at the highest cervical level (C1-C4), and thus have lost voluntary control of most of the shoulder and arm muscles. To determine the optimal electrode set for this system, given the limited number of available stimulating channels, a musculoskeletal model of the upper extremity was used to run a large number of simulations and evaluate all the candidate electrode sets. The model was customized to represent a tetraplegic subject with an FES system, and the optimal electrode set was the one that allowed the model to successfully perform the largest number of movements. Subsequently, a combined feedforward-feedback controller approach was developed and tested first in a simplified arm model with six muscles and two degrees of freedom. In spite of its small scale, the model included an accurate muscle model, redundancy in the number of muscles, and kinematic coupling. It demonstrated the excellent trajectory tracking performance of the controller, even in the presence of considerable muscle fatigue and external forces. Next, the same design, augmented by a controller for shoulder stability was tested in a large-scale arm model with 22 muscles and five degrees of freedom, including a complete glenohumeral joint. In addition to its tracking ability, this controller was able to ensure shoulder stability in all cases of external disturbances. Finally, the controller was implemented in one subject with high level tetraplegia, and an adaptation method was developed to adjust the controller parameters according to the characteristics of the specific individual. In order to handle the redundancy of the upper limb, adaptation was performed using co-contraction of antagonistic muscles, and activation patterns among shoulder stabilizing and moving muscles. When tested in the shoulder and elbow of the subject, the controller achieved adaptation and allowed the execution of the desired movements.","abstract_has_math":false,"creators":["Blana, Dimitra"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Kirsch, Robert"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-03-31","date_published":"2008-03-31","updated_at":"2026-11-26T03:17:30Z","subjects":["Biomedical Research","Rehabilitation","biomechanics","functional electrical stimulation","musculoskeletal modeling","feedback control"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1206994969","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1206994969","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1206994969","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1206994969","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kirsch, Robert"]},{"key":"dc:creator","label":"Author","values":["Blana, Dimitra"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-03-31"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","Rehabilitation","biomechanics","functional electrical stimulation","musculoskeletal modeling","feedback control"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1206994969"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The main focus of this study is controller design using a model-based approach, and implementation in a high level upper extremity neuroprosthesis. This is a system that aims to restore upper limb motor function to individuals who have suffered a spinal cord injury at the highest cervical level (C1-C4), and thus have lost voluntary control of most of the shoulder and arm muscles. To determine the optimal electrode set for this system, given the limited number of available stimulating channels, a musculoskeletal model of the upper extremity was used to run a large number of simulations and evaluate all the candidate electrode sets. The model was customized to represent a tetraplegic subject with an FES system, and the optimal electrode set was the one that allowed the model to successfully perform the largest number of movements. Subsequently, a combined feedforward-feedback controller approach was developed and tested first in a simplified arm model with six muscles and two degrees of freedom. In spite of its small scale, the model included an accurate muscle model, redundancy in the number of muscles, and kinematic coupling. It demonstrated the excellent trajectory tracking performance of the controller, even in the presence of considerable muscle fatigue and external forces. Next, the same design, augmented by a controller for shoulder stability was tested in a large-scale arm model with 22 muscles and five degrees of freedom, including a complete glenohumeral joint. In addition to its tracking ability, this controller was able to ensure shoulder stability in all cases of external disturbances. Finally, the controller was implemented in one subject with high level tetraplegia, and an adaptation method was developed to adjust the controller parameters according to the characteristics of the specific individual. In order to handle the redundancy of the upper limb, adaptation was performed using co-contraction of antagonistic muscles, and activation patterns among shoulder stabilizing and moving muscles. When tested in the shoulder and elbow of the subject, the controller achieved adaptation and allowed the execution of the desired movements."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.151","883.1 KB"]},{"key":"dc:title","label":"Title","values":["Feedback Control of a High Level Upper Extremity Neuroprosthesis"]}]}],"canonical_facts":{"dc:contributor":["Kirsch, Robert"],"dc:creator":["Blana, Dimitra"],"dc:date":["2008-03-31"],"dc:description":["The main focus of this study is controller design using a model-based approach, and implementation in a high level upper extremity neuroprosthesis. This is a system that aims to restore upper limb motor function to individuals who have suffered a spinal cord injury at the highest cervical level (C1-C4), and thus have lost voluntary control of most of the shoulder and arm muscles. To determine the optimal electrode set for this system, given the limited number of available stimulating channels, a musculoskeletal model of the upper extremity was used to run a large number of simulations and evaluate all the candidate electrode sets. The model was customized to represent a tetraplegic subject with an FES system, and the optimal electrode set was the one that allowed the model to successfully perform the largest number of movements. Subsequently, a combined feedforward-feedback controller approach was developed and tested first in a simplified arm model with six muscles and two degrees of freedom. In spite of its small scale, the model included an accurate muscle model, redundancy in the number of muscles, and kinematic coupling. It demonstrated the excellent trajectory tracking performance of the controller, even in the presence of considerable muscle fatigue and external forces. Next, the same design, augmented by a controller for shoulder stability was tested in a large-scale arm model with 22 muscles and five degrees of freedom, including a complete glenohumeral joint. In addition to its tracking ability, this controller was able to ensure shoulder stability in all cases of external disturbances. Finally, the controller was implemented in one subject with high level tetraplegia, and an adaptation method was developed to adjust the controller parameters according to the characteristics of the specific individual. In order to handle the redundancy of the upper limb, adaptation was performed using co-contraction of antagonistic muscles, and activation patterns among shoulder stabilizing and moving muscles. When tested in the shoulder and elbow of the subject, the controller achieved adaptation and allowed the execution of the desired movements."],"dc:format":["application/pdf","p.151","883.1 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1206994969"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","Rehabilitation","biomechanics","functional electrical stimulation","musculoskeletal modeling","feedback control"],"dc:title":["Feedback Control of a High Level Upper Extremity Neuroprosthesis"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:17:30Z"}