{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1207083143"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1207083143","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"FASCICULAR PERINEURIUM THICKNESS, SIZE, AND POSITION AFFECT MODEL PREDICTIONS OF NEURAL EXCITATION","abstract":"This project evaluated the effects of fascicle perineurial thickness, diameter, and position on axon stimulation thresholds and target fascicle recruitment using finite element models and Neuron simulations. The perineurial thickness of human fascicles was found to be 3.0% ± 1.0% of the fascicle diameter. Increased perineurial thickness and fascicle diameter resulted in increased activation thresholds. A large neighboring fascicle caused a significant change in percent activation of the smaller target fascicle by as much as 80%, as compared to models without a neighboring fascicle. Therefore, smaller fascicles were recruited at lower amplitudes than the neighboring larger fascicles. These effects were further presented in a realistic nerve model using a section of a human femoral nerve and nerve cuff electrode. These results demonstrate that fascicular selectivity is strongly dependent on the nerve anatomy. Therefore, physiologically accurate computer models are recommended for evaluation and optimization of electrode designs for neural prosthesis applications.","abstract_html":"This project evaluated the effects of fascicle perineurial thickness, diameter, and position on axon stimulation thresholds and target fascicle recruitment using finite element models and Neuron simulations. The perineurial thickness of human fascicles was found to be 3.0% ± 1.0% of the fascicle diameter. Increased perineurial thickness and fascicle diameter resulted in increased activation thresholds. A large neighboring fascicle caused a significant change in percent activation of the smaller target fascicle by as much as 80%, as compared to models without a neighboring fascicle. Therefore, smaller fascicles were recruited at lower amplitudes than the neighboring larger fascicles. These effects were further presented in a realistic nerve model using a section of a human femoral nerve and nerve cuff electrode. These results demonstrate that fascicular selectivity is strongly dependent on the nerve anatomy. Therefore, physiologically accurate computer models are recommended for evaluation and optimization of electrode designs for neural prosthesis applications.","abstract_has_math":false,"creators":["Grinberg, Yanina"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Gustafson, Kenneth"],"committee_members":[],"year":2008,"date_issued":"2008-04-02","date_published":"2008-04-02","updated_at":"2026-11-27T04:14:31Z","subjects":["Biomedical Research","Engineering","Neurology","Selective stimulation","computer models","nerve cuff electrode","neural anatomy","fascicle","perineurium"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1207083143","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1207083143","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1207083143","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1207083143","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Gustafson, Kenneth"]},{"key":"dc:creator","label":"Author","values":["Grinberg, Yanina"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-04-02"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","Engineering","Neurology","Selective stimulation","computer models","nerve cuff electrode","neural anatomy","fascicle","perineurium"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1207083143"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This project evaluated the effects of fascicle perineurial thickness, diameter, and position on axon stimulation thresholds and target fascicle recruitment using finite element models and Neuron simulations. The perineurial thickness of human fascicles was found to be 3.0% ± 1.0% of the fascicle diameter. Increased perineurial thickness and fascicle diameter resulted in increased activation thresholds. A large neighboring fascicle caused a significant change in percent activation of the smaller target fascicle by as much as 80%, as compared to models without a neighboring fascicle. Therefore, smaller fascicles were recruited at lower amplitudes than the neighboring larger fascicles. These effects were further presented in a realistic nerve model using a section of a human femoral nerve and nerve cuff electrode. These results demonstrate that fascicular selectivity is strongly dependent on the nerve anatomy. Therefore, physiologically accurate computer models are recommended for evaluation and optimization of electrode designs for neural prosthesis applications."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.49","1.11 MB"]},{"key":"dc:title","label":"Title","values":["FASCICULAR PERINEURIUM THICKNESS, SIZE, AND POSITION AFFECT MODEL PREDICTIONS OF NEURAL EXCITATION"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Gustafson, Kenneth"],"dc:creator":["Grinberg, Yanina"],"dc:date":["2008-04-02"],"dc:description":["This project evaluated the effects of fascicle perineurial thickness, diameter, and position on axon stimulation thresholds and target fascicle recruitment using finite element models and Neuron simulations. The perineurial thickness of human fascicles was found to be 3.0% ± 1.0% of the fascicle diameter. Increased perineurial thickness and fascicle diameter resulted in increased activation thresholds. A large neighboring fascicle caused a significant change in percent activation of the smaller target fascicle by as much as 80%, as compared to models without a neighboring fascicle. Therefore, smaller fascicles were recruited at lower amplitudes than the neighboring larger fascicles. These effects were further presented in a realistic nerve model using a section of a human femoral nerve and nerve cuff electrode. These results demonstrate that fascicular selectivity is strongly dependent on the nerve anatomy. Therefore, physiologically accurate computer models are recommended for evaluation and optimization of electrode designs for neural prosthesis applications."],"dc:format":["application/pdf","p.49","1.11 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1207083143"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","Engineering","Neurology","Selective stimulation","computer models","nerve cuff electrode","neural anatomy","fascicle","perineurium"],"dc:title":["FASCICULAR PERINEURIUM THICKNESS, SIZE, AND POSITION AFFECT MODEL PREDICTIONS OF NEURAL EXCITATION"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:31Z"}