{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1207335588"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1207335588","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"DESIGN AND FABRICATION OF POLYNORBORNENE- AND LIQUID CRYSTAL POLYMER-BASED ELECTRODE ARRAYS FOR BIOMEDICAL APPLICATIONS","abstract":"Conventional peripheral nerve electrodes are often hand-made devices that incorporate platinum foil contacts and stainless steel wires, requiring significant skill and time to fabricate, and the contact density is limited by the manufacturing method. Microfabrication allows for batch processing, eliminates hand assembly, and permits a much higher contact density. Liquid crystal polymer (LCP) is a good choice as a substrate material for flexible, microfabricated electrode arrays because it is mechanically robust and resistant to moisture absorption. However microfabrication of multilayerd LCP devices is challenging because lamination is required. This thesis describes the development of peripheral nerve electrode prototypes fabricated using LCP, polynorbornene and thin film platinum. The fabrication process involves photolithographic patterning of the platinum and PNB layers, and laser micromachining of LCP. Benchtop testing was performed to evaluate the mechanical, electrical and hermetic properties of the devices. Preliminary in-vivo evaluation showed that the prototypes could be used for stimulation.","abstract_html":"Conventional peripheral nerve electrodes are often hand-made devices that incorporate platinum foil contacts and stainless steel wires, requiring significant skill and time to fabricate, and the contact density is limited by the manufacturing method. Microfabrication allows for batch processing, eliminates hand assembly, and permits a much higher contact density. Liquid crystal polymer (LCP) is a good choice as a substrate material for flexible, microfabricated electrode arrays because it is mechanically robust and resistant to moisture absorption. However microfabrication of multilayerd LCP devices is challenging because lamination is required. This thesis describes the development of peripheral nerve electrode prototypes fabricated using LCP, polynorbornene and thin film platinum. The fabrication process involves photolithographic patterning of the platinum and PNB layers, and laser micromachining of LCP. Benchtop testing was performed to evaluate the mechanical, electrical and hermetic properties of the devices. Preliminary in-vivo evaluation showed that the prototypes could be used for stimulation.","abstract_has_math":false,"creators":["Hess, Allison Elizabeth"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Zorman, Christian"],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-04-04","date_published":"2008-04-04","updated_at":"2026-11-27T04:14:31Z","subjects":["Biomedical Research","Electrical Engineering","Engineering","liquid crystal polymer","LCP","polynorbornene","PNB","microfabrication","neural interface","flexible electrode array"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1207335588","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1207335588","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1207335588","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1207335588","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zorman, Christian"]},{"key":"dc:creator","label":"Author","values":["Hess, Allison Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-04-04"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","Electrical Engineering","Engineering","liquid crystal polymer","LCP","polynorbornene","PNB","microfabrication","neural interface","flexible electrode array"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1207335588"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Conventional peripheral nerve electrodes are often hand-made devices that incorporate platinum foil contacts and stainless steel wires, requiring significant skill and time to fabricate, and the contact density is limited by the manufacturing method. Microfabrication allows for batch processing, eliminates hand assembly, and permits a much higher contact density. Liquid crystal polymer (LCP) is a good choice as a substrate material for flexible, microfabricated electrode arrays because it is mechanically robust and resistant to moisture absorption. However microfabrication of multilayerd LCP devices is challenging because lamination is required. This thesis describes the development of peripheral nerve electrode prototypes fabricated using LCP, polynorbornene and thin film platinum. The fabrication process involves photolithographic patterning of the platinum and PNB layers, and laser micromachining of LCP. Benchtop testing was performed to evaluate the mechanical, electrical and hermetic properties of the devices. Preliminary in-vivo evaluation showed that the prototypes could be used for stimulation."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.164","2.72 MB"]},{"key":"dc:title","label":"Title","values":["DESIGN AND FABRICATION OF POLYNORBORNENE- AND LIQUID CRYSTAL POLYMER-BASED ELECTRODE ARRAYS FOR BIOMEDICAL APPLICATIONS"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zorman, Christian"],"dc:creator":["Hess, Allison Elizabeth"],"dc:date":["2008-04-04"],"dc:description":["Conventional peripheral nerve electrodes are often hand-made devices that incorporate platinum foil contacts and stainless steel wires, requiring significant skill and time to fabricate, and the contact density is limited by the manufacturing method. Microfabrication allows for batch processing, eliminates hand assembly, and permits a much higher contact density. Liquid crystal polymer (LCP) is a good choice as a substrate material for flexible, microfabricated electrode arrays because it is mechanically robust and resistant to moisture absorption. However microfabrication of multilayerd LCP devices is challenging because lamination is required. This thesis describes the development of peripheral nerve electrode prototypes fabricated using LCP, polynorbornene and thin film platinum. The fabrication process involves photolithographic patterning of the platinum and PNB layers, and laser micromachining of LCP. Benchtop testing was performed to evaluate the mechanical, electrical and hermetic properties of the devices. Preliminary in-vivo evaluation showed that the prototypes could be used for stimulation."],"dc:format":["application/pdf","p.164","2.72 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1207335588"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","Electrical Engineering","Engineering","liquid crystal polymer","LCP","polynorbornene","PNB","microfabrication","neural interface","flexible electrode array"],"dc:title":["DESIGN AND FABRICATION OF POLYNORBORNENE- AND LIQUID CRYSTAL POLYMER-BASED ELECTRODE ARRAYS FOR BIOMEDICAL APPLICATIONS"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:31Z"}