{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1207340565"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1207340565","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Imaging the Embryonic Heart with Optical Coherence Tomography","abstract":"Abnormalities that occur during cardiac looping in the early embryo are responsible for congenital heart disease. To date researchers have had to rely upon bioassays, video microscopy and mathematical models to investigate the mechanisms underlying development during looping. Direct observation of looping has been problematic due to the diminutive size (< 2 mm) of the heart and the inability to measure the small and rapid events that influence heart development. Optical coherence tomography (OCT) is a noninvasive imaging tool with the spatiotemporal resolution and field of view to observe both structure and function during the critical time period of looping. Here we present several techniques and studies completed over the past several years to investigate the early embryonic heart. First, 3D imaging enabled us to phenotype embryonic murine hearts, which enabled us to discern HEXIM1 mutants from their wild type littermates. Second, we paced excised avian and murine hearts and gated our image acquisition off the pacing signal to create 4D datasets of the beating heart. Physiological parameters such as ejection fraction and wall thickness were measured. Next, we gated our system to a laser Doppler signal to enable in vivo imaging of embryonic quail hearts. Third, an ultrahigh-speed swept light source (Fourier Domain Mode Locked (FDML) laser) capable of imaging 117,000 axial scans per second was used to observe systolic dynamics. The velocity of the propagating contraction wave was 5 fold faster at the inflow of the heart tube compared to the outflow. Finally, an FDML-based OCT system was integrated with an environmental chamber to image the growth of the embryo over the stages of cardiac looping. Using OCT technology, preload, afterload, and effects of blood flow on the morphological and mechanical changes that occur throughout the looping process can be examined more closely and serve as a baseline for future work that will define environmental, genetic and mechanical factors that impinge on the developing heart and can result in congenital defects.","abstract_html":"Abnormalities that occur during cardiac looping in the early embryo are responsible for congenital heart disease. To date researchers have had to rely upon bioassays, video microscopy and mathematical models to investigate the mechanisms underlying development during looping. Direct observation of looping has been problematic due to the diminutive size (&lt; 2 mm) of the heart and the inability to measure the small and rapid events that influence heart development. Optical coherence tomography (OCT) is a noninvasive imaging tool with the spatiotemporal resolution and field of view to observe both structure and function during the critical time period of looping. Here we present several techniques and studies completed over the past several years to investigate the early embryonic heart. First, 3D imaging enabled us to phenotype embryonic murine hearts, which enabled us to discern HEXIM1 mutants from their wild type littermates. Second, we paced excised avian and murine hearts and gated our image acquisition off the pacing signal to create 4D datasets of the beating heart. Physiological parameters such as ejection fraction and wall thickness were measured. Next, we gated our system to a laser Doppler signal to enable in vivo imaging of embryonic quail hearts. Third, an ultrahigh-speed swept light source (Fourier Domain Mode Locked (FDML) laser) capable of imaging 117,000 axial scans per second was used to observe systolic dynamics. The velocity of the propagating contraction wave was 5 fold faster at the inflow of the heart tube compared to the outflow. Finally, an FDML-based OCT system was integrated with an environmental chamber to image the growth of the embryo over the stages of cardiac looping. Using OCT technology, preload, afterload, and effects of blood flow on the morphological and mechanical changes that occur throughout the looping process can be examined more closely and serve as a baseline for future work that will define environmental, genetic and mechanical factors that impinge on the developing heart and can result in congenital defects.","abstract_has_math":false,"creators":["Jenkins, Michael W."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Rollins, Andrew"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-04-04","date_published":"2008-04-04","updated_at":"2026-11-26T03:17:30Z","subjects":["Biomedical Research","optical coherence tomography","embryonic heart","gated imaging","heart development"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1207340565","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1207340565","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1207340565","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1207340565","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Rollins, Andrew"]},{"key":"dc:creator","label":"Author","values":["Jenkins, Michael W."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-04-04"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","optical coherence tomography","embryonic heart","gated imaging","heart development"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1207340565"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Abnormalities that occur during cardiac looping in the early embryo are responsible for congenital heart disease. To date researchers have had to rely upon bioassays, video microscopy and mathematical models to investigate the mechanisms underlying development during looping. Direct observation of looping has been problematic due to the diminutive size (< 2 mm) of the heart and the inability to measure the small and rapid events that influence heart development. Optical coherence tomography (OCT) is a noninvasive imaging tool with the spatiotemporal resolution and field of view to observe both structure and function during the critical time period of looping. Here we present several techniques and studies completed over the past several years to investigate the early embryonic heart. First, 3D imaging enabled us to phenotype embryonic murine hearts, which enabled us to discern HEXIM1 mutants from their wild type littermates. Second, we paced excised avian and murine hearts and gated our image acquisition off the pacing signal to create 4D datasets of the beating heart. Physiological parameters such as ejection fraction and wall thickness were measured. Next, we gated our system to a laser Doppler signal to enable in vivo imaging of embryonic quail hearts. Third, an ultrahigh-speed swept light source (Fourier Domain Mode Locked (FDML) laser) capable of imaging 117,000 axial scans per second was used to observe systolic dynamics. The velocity of the propagating contraction wave was 5 fold faster at the inflow of the heart tube compared to the outflow. Finally, an FDML-based OCT system was integrated with an environmental chamber to image the growth of the embryo over the stages of cardiac looping. Using OCT technology, preload, afterload, and effects of blood flow on the morphological and mechanical changes that occur throughout the looping process can be examined more closely and serve as a baseline for future work that will define environmental, genetic and mechanical factors that impinge on the developing heart and can result in congenital defects."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.172","3.17 MB"]},{"key":"dc:title","label":"Title","values":["Imaging the Embryonic Heart with Optical Coherence Tomography"]}]}],"canonical_facts":{"dc:contributor":["Rollins, Andrew"],"dc:creator":["Jenkins, Michael W."],"dc:date":["2008-04-04"],"dc:description":["Abnormalities that occur during cardiac looping in the early embryo are responsible for congenital heart disease. To date researchers have had to rely upon bioassays, video microscopy and mathematical models to investigate the mechanisms underlying development during looping. Direct observation of looping has been problematic due to the diminutive size (< 2 mm) of the heart and the inability to measure the small and rapid events that influence heart development. Optical coherence tomography (OCT) is a noninvasive imaging tool with the spatiotemporal resolution and field of view to observe both structure and function during the critical time period of looping. Here we present several techniques and studies completed over the past several years to investigate the early embryonic heart. First, 3D imaging enabled us to phenotype embryonic murine hearts, which enabled us to discern HEXIM1 mutants from their wild type littermates. Second, we paced excised avian and murine hearts and gated our image acquisition off the pacing signal to create 4D datasets of the beating heart. Physiological parameters such as ejection fraction and wall thickness were measured. Next, we gated our system to a laser Doppler signal to enable in vivo imaging of embryonic quail hearts. Third, an ultrahigh-speed swept light source (Fourier Domain Mode Locked (FDML) laser) capable of imaging 117,000 axial scans per second was used to observe systolic dynamics. The velocity of the propagating contraction wave was 5 fold faster at the inflow of the heart tube compared to the outflow. Finally, an FDML-based OCT system was integrated with an environmental chamber to image the growth of the embryo over the stages of cardiac looping. Using OCT technology, preload, afterload, and effects of blood flow on the morphological and mechanical changes that occur throughout the looping process can be examined more closely and serve as a baseline for future work that will define environmental, genetic and mechanical factors that impinge on the developing heart and can result in congenital defects."],"dc:format":["application/pdf","p.172","3.17 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1207340565"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","optical coherence tomography","embryonic heart","gated imaging","heart development"],"dc:title":["Imaging the Embryonic Heart with Optical Coherence Tomography"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:17:30Z"}