{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1212587760"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1212587760","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Low-Power Wireless Transceiver for Deeply Implanted Biomedical Devices","abstract":"This work presents the design of a low-power wireless transceiver optimized for use in deeply implanted biomedical devices. Potential operating frequencies were analyzed with respect to system limitations of power, size and complexity. It was reasoned that operation using low carrier frequencies provides high power efficiency while slightly increasing the size of off-chip antennas, and 125-kHz OOK and 27.12-MHz FSK were chosen for forward- and reverse-telemetry, respectively. Integrated telemetry circuits were designed to meet the power and data rate requirements for simple biomedical devices and the circuits were fabricated in the AMI 0.5-μm CMOS process. Test measurements have confirmed the functionality of the circuits, and have provided inspiration for future circuit redesign.","abstract_html":"This work presents the design of a low-power wireless transceiver optimized for use in deeply implanted biomedical devices. Potential operating frequencies were analyzed with respect to system limitations of power, size and complexity. It was reasoned that operation using low carrier frequencies provides high power efficiency while slightly increasing the size of off-chip antennas, and 125-kHz OOK and 27.12-MHz FSK were chosen for forward- and reverse-telemetry, respectively. Integrated telemetry circuits were designed to meet the power and data rate requirements for simple biomedical devices and the circuits were fabricated in the AMI 0.5-μm CMOS process. Test measurements have confirmed the functionality of the circuits, and have provided inspiration for future circuit redesign.","abstract_has_math":false,"creators":["Majerus, Steve J.A."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":["Garverick, Steven"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-06-04","date_published":"2008-06-04","updated_at":"2026-11-26T03:17:30Z","subjects":["Electrical Engineering","wireless transceiver","receiver","transmitter","CMOS","Manchester Decoder"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1212587760","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1212587760","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1212587760","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1212587760","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Garverick, Steven"]},{"key":"dc:creator","label":"Author","values":["Majerus, Steve J.A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-06-04"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering","wireless transceiver","receiver","transmitter","CMOS","Manchester Decoder"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1212587760"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This work presents the design of a low-power wireless transceiver optimized for use in deeply implanted biomedical devices. Potential operating frequencies were analyzed with respect to system limitations of power, size and complexity. It was reasoned that operation using low carrier frequencies provides high power efficiency while slightly increasing the size of off-chip antennas, and 125-kHz OOK and 27.12-MHz FSK were chosen for forward- and reverse-telemetry, respectively. Integrated telemetry circuits were designed to meet the power and data rate requirements for simple biomedical devices and the circuits were fabricated in the AMI 0.5-μm CMOS process. Test measurements have confirmed the functionality of the circuits, and have provided inspiration for future circuit redesign."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.79","1.5 MB"]},{"key":"dc:title","label":"Title","values":["Low-Power Wireless Transceiver for Deeply Implanted Biomedical Devices"]}]}],"canonical_facts":{"dc:contributor":["Garverick, Steven"],"dc:creator":["Majerus, Steve J.A."],"dc:date":["2008-06-04"],"dc:description":["This work presents the design of a low-power wireless transceiver optimized for use in deeply implanted biomedical devices. Potential operating frequencies were analyzed with respect to system limitations of power, size and complexity. It was reasoned that operation using low carrier frequencies provides high power efficiency while slightly increasing the size of off-chip antennas, and 125-kHz OOK and 27.12-MHz FSK were chosen for forward- and reverse-telemetry, respectively. Integrated telemetry circuits were designed to meet the power and data rate requirements for simple biomedical devices and the circuits were fabricated in the AMI 0.5-μm CMOS process. Test measurements have confirmed the functionality of the circuits, and have provided inspiration for future circuit redesign."],"dc:format":["application/pdf","p.79","1.5 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1212587760"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Electrical Engineering","wireless transceiver","receiver","transmitter","CMOS","Manchester Decoder"],"dc:title":["Low-Power Wireless Transceiver for Deeply Implanted Biomedical Devices"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:17:30Z"}