{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1216401371"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1216401371","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Interface Electronics for Peripheral Nerve Recording and Signal Processing","abstract":"Interface electronics for peripheral nerve recording and analog signal processing is developed in this work as part of sensing mechanism for a laryngeal pacemaker to reanimate the paralyzed larynx in subjects with bilateral vocal fold paralysis. The electronic system has been designed to record neural activity from the phrenic nerve, condition the neural signal, and provide activity-dependent triggering for stimulator control. The system has been implemented in discrete fashion with commercial off-the-shelf components as well as integrated on a single 2.2 × 2.2-mm<sup>2</sup> chip fabricated using the AMI 1.5 μm 2P/2M n-well CMOS process. System architecture, circuit design and analysis, simulation results, and measurement data from benchtop experiments with pre-recorded neural activity are presented and discussed.","abstract_html":"Interface electronics for peripheral nerve recording and analog signal processing is developed in this work as part of sensing mechanism for a laryngeal pacemaker to reanimate the paralyzed larynx in subjects with bilateral vocal fold paralysis. The electronic system has been designed to record neural activity from the phrenic nerve, condition the neural signal, and provide activity-dependent triggering for stimulator control. The system has been implemented in discrete fashion with commercial off-the-shelf components as well as integrated on a single 2.2 × 2.2-mm&lt;sup&gt;2&lt;/sup&gt; chip fabricated using the AMI 1.5 μm 2P/2M n-well CMOS process. System architecture, circuit design and analysis, simulation results, and measurement data from benchtop experiments with pre-recorded neural activity are presented and discussed.","abstract_has_math":false,"creators":["Limnuson, Kanokwan"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"Electrical Engineering and Computer Science - Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Mohseni, Pedram"],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-07-22","date_published":"2008-07-22","updated_at":"2026-11-27T04:14:31Z","subjects":["Electrical Engineering","interface electronics","neural recording","signal processing"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1216401371","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1216401371","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1216401371","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1216401371","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mohseni, Pedram"]},{"key":"dc:creator","label":"Author","values":["Limnuson, Kanokwan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-07-22"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering and Computer Science - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering","interface electronics","neural recording","signal processing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1216401371"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Interface electronics for peripheral nerve recording and analog signal processing is developed in this work as part of sensing mechanism for a laryngeal pacemaker to reanimate the paralyzed larynx in subjects with bilateral vocal fold paralysis. The electronic system has been designed to record neural activity from the phrenic nerve, condition the neural signal, and provide activity-dependent triggering for stimulator control. The system has been implemented in discrete fashion with commercial off-the-shelf components as well as integrated on a single 2.2 × 2.2-mm<sup>2</sup> chip fabricated using the AMI 1.5 μm 2P/2M n-well CMOS process. System architecture, circuit design and analysis, simulation results, and measurement data from benchtop experiments with pre-recorded neural activity are presented and discussed."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.71","1.59 MB"]},{"key":"dc:title","label":"Title","values":["Interface Electronics for Peripheral Nerve Recording and Signal Processing"]}]}],"canonical_facts":{"dc:contributor.advisor":["Mohseni, Pedram"],"dc:creator":["Limnuson, Kanokwan"],"dc:date":["2008-07-22"],"dc:description":["Interface electronics for peripheral nerve recording and analog signal processing is developed in this work as part of sensing mechanism for a laryngeal pacemaker to reanimate the paralyzed larynx in subjects with bilateral vocal fold paralysis. The electronic system has been designed to record neural activity from the phrenic nerve, condition the neural signal, and provide activity-dependent triggering for stimulator control. The system has been implemented in discrete fashion with commercial off-the-shelf components as well as integrated on a single 2.2 × 2.2-mm<sup>2</sup> chip fabricated using the AMI 1.5 μm 2P/2M n-well CMOS process. System architecture, circuit design and analysis, simulation results, and measurement data from benchtop experiments with pre-recorded neural activity are presented and discussed."],"dc:format":["application/pdf","p.71","1.59 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1216401371"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Electrical Engineering","interface electronics","neural recording","signal processing"],"dc:title":["Interface Electronics for Peripheral Nerve Recording and Signal Processing"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Electrical Engineering and Computer Science - Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:31Z"}