{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1220639010"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1220639010","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Microcontroller-Based, Dual-Channel Wireless Neural Recorder/Stimulator","abstract":"<p>Two, dual-channel wireless neural recording and stimulation devices are presented. The basic version has a neural preamplifier in series with a second amplifier to provide a signal gain of 4000. A multiplexer selects the recording channel. An 8-bit ADC converts the analog neural data into a digital stream, which is Manchester-encoded and frequency-shift-key (FSK) modulated at 27.12 MHz, before being transmitted to the host transceiver. The device receives 125-kHz on-off-keyed (OOK) commands, allowing the user to change record channels, program stimulation parameters, and trigger stimulus.</p><p>The electrical performance of the basic version has been measured and compared to theoretical results. In vitro and in vivo animal experiments are reported. A comparison of wired and wireless data is in good agreement. Commands are properly received.</p><p>The advanced version has additional integration, circuit revisions, and provides support for on-board digital data processing. Basic functionality of the advanced prototype has been verified.</p>","abstract_html":"&lt;p&gt;Two, dual-channel wireless neural recording and stimulation devices are presented. The basic version has a neural preamplifier in series with a second amplifier to provide a signal gain of 4000. A multiplexer selects the recording channel. An 8-bit ADC converts the analog neural data into a digital stream, which is Manchester-encoded and frequency-shift-key (FSK) modulated at 27.12 MHz, before being transmitted to the host transceiver. The device receives 125-kHz on-off-keyed (OOK) commands, allowing the user to change record channels, program stimulation parameters, and trigger stimulus.&lt;/p&gt;&lt;p&gt;The electrical performance of the basic version has been measured and compared to theoretical results. In vitro and in vivo animal experiments are reported. A comparison of wired and wireless data is in good agreement. Commands are properly received.&lt;/p&gt;&lt;p&gt;The advanced version has additional integration, circuit revisions, and provides support for on-board digital data processing. Basic functionality of the advanced prototype has been verified.&lt;/p&gt;","abstract_has_math":false,"creators":["Dorr, Christopher R."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"Electrical Engineering and Computer Science - Electrical Engineering","degree_department":null,"school":null,"contributors":["Garverick, Steven"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009","date_published":"2009","updated_at":"2026-11-26T03:17:45Z","subjects":["Biology","Biomedical Research","Electrical Engineering","neural recorder","neural stimulator","wireless","implantable","Aplysia"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1220639010","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1220639010","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1220639010","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1220639010","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Garverick, Steven"]},{"key":"dc:creator","label":"Author","values":["Dorr, Christopher R."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering and Computer Science - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biology","Biomedical Research","Electrical Engineering","neural recorder","neural stimulator","wireless","implantable","Aplysia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1220639010"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Two, dual-channel wireless neural recording and stimulation devices are presented. The basic version has a neural preamplifier in series with a second amplifier to provide a signal gain of 4000. A multiplexer selects the recording channel. An 8-bit ADC converts the analog neural data into a digital stream, which is Manchester-encoded and frequency-shift-key (FSK) modulated at 27.12 MHz, before being transmitted to the host transceiver. The device receives 125-kHz on-off-keyed (OOK) commands, allowing the user to change record channels, program stimulation parameters, and trigger stimulus.</p><p>The electrical performance of the basic version has been measured and compared to theoretical results. In vitro and in vivo animal experiments are reported. A comparison of wired and wireless data is in good agreement. Commands are properly received.</p><p>The advanced version has additional integration, circuit revisions, and provides support for on-board digital data processing. Basic functionality of the advanced prototype has been verified.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.130","2.58 MB"]},{"key":"dc:title","label":"Title","values":["Microcontroller-Based, Dual-Channel Wireless Neural Recorder/Stimulator"]}]}],"canonical_facts":{"dc:contributor":["Garverick, Steven"],"dc:creator":["Dorr, Christopher R."],"dc:date":["2009"],"dc:description":["<p>Two, dual-channel wireless neural recording and stimulation devices are presented. The basic version has a neural preamplifier in series with a second amplifier to provide a signal gain of 4000. A multiplexer selects the recording channel. An 8-bit ADC converts the analog neural data into a digital stream, which is Manchester-encoded and frequency-shift-key (FSK) modulated at 27.12 MHz, before being transmitted to the host transceiver. The device receives 125-kHz on-off-keyed (OOK) commands, allowing the user to change record channels, program stimulation parameters, and trigger stimulus.</p><p>The electrical performance of the basic version has been measured and compared to theoretical results. In vitro and in vivo animal experiments are reported. A comparison of wired and wireless data is in good agreement. Commands are properly received.</p><p>The advanced version has additional integration, circuit revisions, and provides support for on-board digital data processing. Basic functionality of the advanced prototype has been verified.</p>"],"dc:format":["application/pdf","p.130","2.58 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1220639010"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biology","Biomedical Research","Electrical Engineering","neural recorder","neural stimulator","wireless","implantable","Aplysia"],"dc:title":["Microcontroller-Based, Dual-Channel Wireless Neural Recorder/Stimulator"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Electrical Engineering and Computer Science - Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:17:45Z"}