{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1224274091"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1224274091","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Image Registration for the Prostate","abstract":"The long-term goal of this research is to develop medical image registration techniques that can improve cancer detection, diagnosis, and therapy. Both rigid-body and deformable image registration methods were developed for human magnetic resonance (MR) images. As reported in Chapter 2, our automatic, three-dimensional (3D), rigid-body registration method has special features that include multi-resolution, multi-similarity, and restarting mechanisms. These features improved the robustness of MR image registration. The automatic registration method has been evaluated for potential applications in prostate MR imaging. However, tissue deformation and patient positions often raise problems for rigid-body registration. In order to improve registration accuracy, 3D thin-plate spline (TPS)-based deformable registration methods were developed and evaluated for pelvic MR images that were acquired at different patient positions/conditions. As described in Chapter 3, our TPS registration methods have several potential applications for image-guided therapy of the prostate. With the recent advancement of small animal imaging technology, MR imaging can provide high-resolution images of a tumor with subtle anatomic details, molecular imaging such as positron emission tomography (PET) can provide functional and metabolic information regarding the tumor. Registration of PET and MR images can combine the strength from the two imaging modalities and thus provides complementary information at the cellular and molecular levels. Chapter 4 proposes and evaluates a finite-element model (FEM)-based registration method for tumor PET and MR images, which can have unique applications in cancer early detection and therapy assessment. Chapter 5 further demonstrates clinical applications of multimodality image registration for prostate cancer patients. Methods were developed for MRI/SPECT registration and CT/SPECT fusion. Finally, Chapter 6 describes the future work of image registration techniques and the conclusion of the research work.","abstract_html":"The long-term goal of this research is to develop medical image registration techniques that can improve cancer detection, diagnosis, and therapy. Both rigid-body and deformable image registration methods were developed for human magnetic resonance (MR) images. As reported in Chapter 2, our automatic, three-dimensional (3D), rigid-body registration method has special features that include multi-resolution, multi-similarity, and restarting mechanisms. These features improved the robustness of MR image registration. The automatic registration method has been evaluated for potential applications in prostate MR imaging. However, tissue deformation and patient positions often raise problems for rigid-body registration. In order to improve registration accuracy, 3D thin-plate spline (TPS)-based deformable registration methods were developed and evaluated for pelvic MR images that were acquired at different patient positions/conditions. As described in Chapter 3, our TPS registration methods have several potential applications for image-guided therapy of the prostate. With the recent advancement of small animal imaging technology, MR imaging can provide high-resolution images of a tumor with subtle anatomic details, molecular imaging such as positron emission tomography (PET) can provide functional and metabolic information regarding the tumor. Registration of PET and MR images can combine the strength from the two imaging modalities and thus provides complementary information at the cellular and molecular levels. Chapter 4 proposes and evaluates a finite-element model (FEM)-based registration method for tumor PET and MR images, which can have unique applications in cancer early detection and therapy assessment. Chapter 5 further demonstrates clinical applications of multimodality image registration for prostate cancer patients. Methods were developed for MRI/SPECT registration and CT/SPECT fusion. Finally, Chapter 6 describes the future work of image registration techniques and the conclusion of the research work.","abstract_has_math":false,"creators":["FEI, Baowei"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"EECS - System and Control Engineering","degree_department":null,"school":null,"contributors":["Loparo, Kenneth"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-10-29","date_published":"2008-10-29","updated_at":"2026-11-26T03:17:45Z","subjects":["Computer Science","Engineering","Radiology","Scientific Imaging","image registration","deformable registration","non-rigid registration","thin plate spline","finite element model","prostate cancer","image-guided therapy","magnetic resonance imaging (MRI)","positron emission tomography (PET)","molecular imaging"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1224274091","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1224274091","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1224274091","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1224274091","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Loparo, Kenneth"]},{"key":"dc:creator","label":"Author","values":["FEI, Baowei"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-10-29"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - System and Control Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Computer Science","Engineering","Radiology","Scientific Imaging","image registration","deformable registration","non-rigid registration","thin plate spline","finite element model","prostate cancer","image-guided therapy","magnetic resonance imaging (MRI)","positron emission tomography (PET)","molecular imaging"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1224274091"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The long-term goal of this research is to develop medical image registration techniques that can improve cancer detection, diagnosis, and therapy. Both rigid-body and deformable image registration methods were developed for human magnetic resonance (MR) images. As reported in Chapter 2, our automatic, three-dimensional (3D), rigid-body registration method has special features that include multi-resolution, multi-similarity, and restarting mechanisms. These features improved the robustness of MR image registration. The automatic registration method has been evaluated for potential applications in prostate MR imaging. However, tissue deformation and patient positions often raise problems for rigid-body registration. In order to improve registration accuracy, 3D thin-plate spline (TPS)-based deformable registration methods were developed and evaluated for pelvic MR images that were acquired at different patient positions/conditions. As described in Chapter 3, our TPS registration methods have several potential applications for image-guided therapy of the prostate. With the recent advancement of small animal imaging technology, MR imaging can provide high-resolution images of a tumor with subtle anatomic details, molecular imaging such as positron emission tomography (PET) can provide functional and metabolic information regarding the tumor. Registration of PET and MR images can combine the strength from the two imaging modalities and thus provides complementary information at the cellular and molecular levels. Chapter 4 proposes and evaluates a finite-element model (FEM)-based registration method for tumor PET and MR images, which can have unique applications in cancer early detection and therapy assessment. Chapter 5 further demonstrates clinical applications of multimodality image registration for prostate cancer patients. Methods were developed for MRI/SPECT registration and CT/SPECT fusion. Finally, Chapter 6 describes the future work of image registration techniques and the conclusion of the research work."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.166","2.56 MB"]},{"key":"dc:title","label":"Title","values":["Image Registration for the Prostate"]}]}],"canonical_facts":{"dc:contributor":["Loparo, Kenneth"],"dc:creator":["FEI, Baowei"],"dc:date":["2008-10-29"],"dc:description":["The long-term goal of this research is to develop medical image registration techniques that can improve cancer detection, diagnosis, and therapy. Both rigid-body and deformable image registration methods were developed for human magnetic resonance (MR) images. As reported in Chapter 2, our automatic, three-dimensional (3D), rigid-body registration method has special features that include multi-resolution, multi-similarity, and restarting mechanisms. These features improved the robustness of MR image registration. The automatic registration method has been evaluated for potential applications in prostate MR imaging. However, tissue deformation and patient positions often raise problems for rigid-body registration. In order to improve registration accuracy, 3D thin-plate spline (TPS)-based deformable registration methods were developed and evaluated for pelvic MR images that were acquired at different patient positions/conditions. As described in Chapter 3, our TPS registration methods have several potential applications for image-guided therapy of the prostate. With the recent advancement of small animal imaging technology, MR imaging can provide high-resolution images of a tumor with subtle anatomic details, molecular imaging such as positron emission tomography (PET) can provide functional and metabolic information regarding the tumor. Registration of PET and MR images can combine the strength from the two imaging modalities and thus provides complementary information at the cellular and molecular levels. Chapter 4 proposes and evaluates a finite-element model (FEM)-based registration method for tumor PET and MR images, which can have unique applications in cancer early detection and therapy assessment. Chapter 5 further demonstrates clinical applications of multimodality image registration for prostate cancer patients. Methods were developed for MRI/SPECT registration and CT/SPECT fusion. Finally, Chapter 6 describes the future work of image registration techniques and the conclusion of the research work."],"dc:format":["application/pdf","p.166","2.56 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1224274091"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Computer Science","Engineering","Radiology","Scientific Imaging","image registration","deformable registration","non-rigid registration","thin plate spline","finite element model","prostate cancer","image-guided therapy","magnetic resonance imaging (MRI)","positron emission tomography (PET)","molecular imaging"],"dc:title":["Image Registration for the Prostate"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - System and Control Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:17:45Z"}