{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1232670698"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1232670698","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Wireless Multichannel Recording/Stimulation System for Neurodynamic Studies of Aplysia","abstract":"<p>In this research, a bi-directional wireless implantable unit and an externaltransceiver which can be used for recording and stimulating neural activity of marinemollusk Aplysia Californica, has been developed. The system supports bidirectionalwireless telemetry in a saltwater environment, using frequency shift keying (FSK) at 27.1MHz to transmit data at 62.5 kbps data rate, and using on-off Keying (OOK) at 125 kHzto receive commands. The implanted device is powered using a 3-V, 160-mAh lithiumionbattery, consumes 21 mW of power, weighs 21.9 gm including the battery, is 4.5 cmby 1.8 cm in size and can operate for 23 hr continuously before the battery dies.Measurement of acute neural activity from a live animal has been demonstrated using thisdevice.</p><p>A fully monolithic bandpass amplifier for neural signal recording in large arrayshas been designed and tested. The measured passband gain is 37.9 dB from 25 Hz to 15kHz and input-referred noise is 1.04 μV rms, with a power consumption of 162 μW and adie area of 0.13 mm2 in a standard 0.5-μm CMOS process.The technology is also demonstrated via a 2x2-mm, fully integrated 4-channelapplication specific integrated circuit (ASIC) in 0.5-μm technology. The ASIC features athree-stage frontend amplifier which provides a maximum gain of 80 dB. The power consumption has been optimized considering the noise (1-μV r.m.s), bandwidth (2 kHz)and resolution (8-bits) requirements. The calculated power consumption per channel ofthe front end amplifier is 22 μWatt.</p><p>The architecture and the performance of the ASIC are scalable to multiplechannels. As such, the device could serve as the basis for a closed-loop controller forprosthetic devices or deep brain stimulation.</p>","abstract_html":"&lt;p&gt;In this research, a bi-directional wireless implantable unit and an externaltransceiver which can be used for recording and stimulating neural activity of marinemollusk Aplysia Californica, has been developed. The system supports bidirectionalwireless telemetry in a saltwater environment, using frequency shift keying (FSK) at 27.1MHz to transmit data at 62.5 kbps data rate, and using on-off Keying (OOK) at 125 kHzto receive commands. The implanted device is powered using a 3-V, 160-mAh lithiumionbattery, consumes 21 mW of power, weighs 21.9 gm including the battery, is 4.5 cmby 1.8 cm in size and can operate for 23 hr continuously before the battery dies.Measurement of acute neural activity from a live animal has been demonstrated using thisdevice.&lt;/p&gt;&lt;p&gt;A fully monolithic bandpass amplifier for neural signal recording in large arrayshas been designed and tested. The measured passband gain is 37.9 dB from 25 Hz to 15kHz and input-referred noise is 1.04 μV rms, with a power consumption of 162 μW and adie area of 0.13 mm2 in a standard 0.5-μm CMOS process.The technology is also demonstrated via a 2x2-mm, fully integrated 4-channelapplication specific integrated circuit (ASIC) in 0.5-μm technology. The ASIC features athree-stage frontend amplifier which provides a maximum gain of 80 dB. The power consumption has been optimized considering the noise (1-μV r.m.s), bandwidth (2 kHz)and resolution (8-bits) requirements. The calculated power consumption per channel ofthe front end amplifier is 22 μWatt.&lt;/p&gt;&lt;p&gt;The architecture and the performance of the ASIC are scalable to multiplechannels. As such, the device could serve as the basis for a closed-loop controller forprosthetic devices or deep brain stimulation.&lt;/p&gt;","abstract_has_math":false,"creators":["Samsukha, Paras"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"EECS - Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Garverick, Steven"],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-01-22","date_published":"2009-01-22","updated_at":"2026-11-27T04:14:38Z","subjects":["Biomedical Research","Electrical Engineering","Engineering","Neural recording","implantable","wireless","low power","multichannel"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1232670698","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1232670698","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1232670698","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1232670698","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Garverick, Steven"]},{"key":"dc:creator","label":"Author","values":["Samsukha, Paras"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009-01-22"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","Electrical Engineering","Engineering","Neural recording","implantable","wireless","low power","multichannel"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1232670698"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>In this research, a bi-directional wireless implantable unit and an externaltransceiver which can be used for recording and stimulating neural activity of marinemollusk Aplysia Californica, has been developed. The system supports bidirectionalwireless telemetry in a saltwater environment, using frequency shift keying (FSK) at 27.1MHz to transmit data at 62.5 kbps data rate, and using on-off Keying (OOK) at 125 kHzto receive commands. The implanted device is powered using a 3-V, 160-mAh lithiumionbattery, consumes 21 mW of power, weighs 21.9 gm including the battery, is 4.5 cmby 1.8 cm in size and can operate for 23 hr continuously before the battery dies.Measurement of acute neural activity from a live animal has been demonstrated using thisdevice.</p><p>A fully monolithic bandpass amplifier for neural signal recording in large arrayshas been designed and tested. The measured passband gain is 37.9 dB from 25 Hz to 15kHz and input-referred noise is 1.04 μV rms, with a power consumption of 162 μW and adie area of 0.13 mm2 in a standard 0.5-μm CMOS process.The technology is also demonstrated via a 2x2-mm, fully integrated 4-channelapplication specific integrated circuit (ASIC) in 0.5-μm technology. The ASIC features athree-stage frontend amplifier which provides a maximum gain of 80 dB. The power consumption has been optimized considering the noise (1-μV r.m.s), bandwidth (2 kHz)and resolution (8-bits) requirements. The calculated power consumption per channel ofthe front end amplifier is 22 μWatt.</p><p>The architecture and the performance of the ASIC are scalable to multiplechannels. As such, the device could serve as the basis for a closed-loop controller forprosthetic devices or deep brain stimulation.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.132","4.47 MB"]},{"key":"dc:title","label":"Title","values":["Wireless Multichannel Recording/Stimulation System for Neurodynamic Studies of Aplysia"]}]}],"canonical_facts":{"dc:contributor.advisor":["Garverick, Steven"],"dc:creator":["Samsukha, Paras"],"dc:date":["2009-01-22"],"dc:description":["<p>In this research, a bi-directional wireless implantable unit and an externaltransceiver which can be used for recording and stimulating neural activity of marinemollusk Aplysia Californica, has been developed. The system supports bidirectionalwireless telemetry in a saltwater environment, using frequency shift keying (FSK) at 27.1MHz to transmit data at 62.5 kbps data rate, and using on-off Keying (OOK) at 125 kHzto receive commands. The implanted device is powered using a 3-V, 160-mAh lithiumionbattery, consumes 21 mW of power, weighs 21.9 gm including the battery, is 4.5 cmby 1.8 cm in size and can operate for 23 hr continuously before the battery dies.Measurement of acute neural activity from a live animal has been demonstrated using thisdevice.</p><p>A fully monolithic bandpass amplifier for neural signal recording in large arrayshas been designed and tested. The measured passband gain is 37.9 dB from 25 Hz to 15kHz and input-referred noise is 1.04 μV rms, with a power consumption of 162 μW and adie area of 0.13 mm2 in a standard 0.5-μm CMOS process.The technology is also demonstrated via a 2x2-mm, fully integrated 4-channelapplication specific integrated circuit (ASIC) in 0.5-μm technology. The ASIC features athree-stage frontend amplifier which provides a maximum gain of 80 dB. The power consumption has been optimized considering the noise (1-μV r.m.s), bandwidth (2 kHz)and resolution (8-bits) requirements. The calculated power consumption per channel ofthe front end amplifier is 22 μWatt.</p><p>The architecture and the performance of the ASIC are scalable to multiplechannels. As such, the device could serve as the basis for a closed-loop controller forprosthetic devices or deep brain stimulation.</p>"],"dc:format":["application/pdf","p.132","4.47 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1232670698"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","Electrical Engineering","Engineering","Neural recording","implantable","wireless","low power","multichannel"],"dc:title":["Wireless Multichannel Recording/Stimulation System for Neurodynamic Studies of Aplysia"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - Electrical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:38Z"}