{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1232680311"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1232680311","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Stability Analysis of Human Walking","abstract":"<p>Stability analyses of human walking could be used to prevent falling by improving stability with assistive or restorative devices. Traditionally, walking stability measures have been defined by logical assumptions about what causes falls. However, the current trend in stability research is toward the use of non-traditional measures based on the idea that human walking is a nonlinear system.</p><p>This study compares emerging non-traditional stability measures, Lyapunov exponents and Floquet multipliers, and a traditional measure, mean standard deviation. The study was conducted in two phases including the analyses of: (1) healthy walking with constraints; and (2) brace and FES-based interventions for multiple sclerosis. </p><p>Results showed that (1) the Lyapunov exponents were the most sensitive measure across constraints and assistive devices; (2) traditional and non-traditional measures did not reveal the same stability effects of the imposed constraints and devices; and (3) there was significant intersubject variability for all constraints and measures.</p>","abstract_html":"&lt;p&gt;Stability analyses of human walking could be used to prevent falling by improving stability with assistive or restorative devices. Traditionally, walking stability measures have been defined by logical assumptions about what causes falls. However, the current trend in stability research is toward the use of non-traditional measures based on the idea that human walking is a nonlinear system.&lt;/p&gt;&lt;p&gt;This study compares emerging non-traditional stability measures, Lyapunov exponents and Floquet multipliers, and a traditional measure, mean standard deviation. The study was conducted in two phases including the analyses of: (1) healthy walking with constraints; and (2) brace and FES-based interventions for multiple sclerosis. &lt;/p&gt;&lt;p&gt;Results showed that (1) the Lyapunov exponents were the most sensitive measure across constraints and assistive devices; (2) traditional and non-traditional measures did not reveal the same stability effects of the imposed constraints and devices; and (3) there was significant intersubject variability for all constraints and measures.&lt;/p&gt;","abstract_has_math":false,"creators":["Everding, Vanessa Quigley"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Triolo, Ronald","Hardin, Elizabeth"],"committee_chairs":["Durand, Dominique"],"committee_members":[],"year":2009,"date_issued":"2009-01-23","date_published":"2009-01-23","updated_at":"2026-11-27T04:14:38Z","subjects":["Biomedical Research","stability","Lyapunov exponents","Floquet Multipliers","multiple sclerosis","funtional electrical stimulation (FES)"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1232680311","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1232680311","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1232680311","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1232680311","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Triolo, Ronald","Hardin, Elizabeth"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Durand, Dominique"]},{"key":"dc:creator","label":"Author","values":["Everding, Vanessa Quigley"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009-01-23"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","stability","Lyapunov exponents","Floquet Multipliers","multiple sclerosis","funtional electrical stimulation (FES)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1232680311"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Stability analyses of human walking could be used to prevent falling by improving stability with assistive or restorative devices. Traditionally, walking stability measures have been defined by logical assumptions about what causes falls. However, the current trend in stability research is toward the use of non-traditional measures based on the idea that human walking is a nonlinear system.</p><p>This study compares emerging non-traditional stability measures, Lyapunov exponents and Floquet multipliers, and a traditional measure, mean standard deviation. The study was conducted in two phases including the analyses of: (1) healthy walking with constraints; and (2) brace and FES-based interventions for multiple sclerosis. </p><p>Results showed that (1) the Lyapunov exponents were the most sensitive measure across constraints and assistive devices; (2) traditional and non-traditional measures did not reveal the same stability effects of the imposed constraints and devices; and (3) there was significant intersubject variability for all constraints and measures.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.192","3.32 MB"]},{"key":"dc:title","label":"Title","values":["Stability Analysis of Human Walking"]}]}],"canonical_facts":{"dc:contributor.advisor":["Triolo, Ronald","Hardin, Elizabeth"],"dc:contributor.committeechair":["Durand, Dominique"],"dc:creator":["Everding, Vanessa Quigley"],"dc:date":["2009-01-23"],"dc:description":["<p>Stability analyses of human walking could be used to prevent falling by improving stability with assistive or restorative devices. Traditionally, walking stability measures have been defined by logical assumptions about what causes falls. However, the current trend in stability research is toward the use of non-traditional measures based on the idea that human walking is a nonlinear system.</p><p>This study compares emerging non-traditional stability measures, Lyapunov exponents and Floquet multipliers, and a traditional measure, mean standard deviation. The study was conducted in two phases including the analyses of: (1) healthy walking with constraints; and (2) brace and FES-based interventions for multiple sclerosis. </p><p>Results showed that (1) the Lyapunov exponents were the most sensitive measure across constraints and assistive devices; (2) traditional and non-traditional measures did not reveal the same stability effects of the imposed constraints and devices; and (3) there was significant intersubject variability for all constraints and measures.</p>"],"dc:format":["application/pdf","p.192","3.32 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1232680311"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","stability","Lyapunov exponents","Floquet Multipliers","multiple sclerosis","funtional electrical stimulation (FES)"],"dc:title":["Stability Analysis of Human Walking"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:38Z"}