{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1244061398"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1244061398","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"A Microfabricated Deep Brain Stimulation Electrode","abstract":"This work presents a novel 4-sided, 16-channel deep brain stimulation electrode with a flexible extension lead for connectivity with pulse generation electronics. The 3-dimensional electrode enables steering the current field circumferentially. The electrode is fabricated in pieces by microfabrication techniques; the pieces are then assembled mechanically, after which the lead is connected. The electrode is modeled by finite element analysis and tested in vitro to validate the design concept, i.e., targeted stimulation. With monopolar and bipolar configurations, the electric potential in front of the activated site is at least five times larger than that on the other not-activated sides within a 3 mm radius. The resistance of each channel is also measured. Finally, a pull test is performed to evaluate the mechanical strength of the epoxy used to attach the lead to the electrode. The samples withstood a force of 8.66 g at a 60° angle, thus exhibiting high robustness.","abstract_html":"This work presents a novel 4-sided, 16-channel deep brain stimulation electrode with a flexible extension lead for connectivity with pulse generation electronics. The 3-dimensional electrode enables steering the current field circumferentially. The electrode is fabricated in pieces by microfabrication techniques; the pieces are then assembled mechanically, after which the lead is connected. The electrode is modeled by finite element analysis and tested in vitro to validate the design concept, i.e., targeted stimulation. With monopolar and bipolar configurations, the electric potential in front of the activated site is at least five times larger than that on the other not-activated sides within a 3 mm radius. The resistance of each channel is also measured. Finally, a pull test is performed to evaluate the mechanical strength of the epoxy used to attach the lead to the electrode. The samples withstood a force of 8.66 g at a 60° angle, thus exhibiting high robustness.","abstract_has_math":false,"creators":["Lin, Chia-Hua"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EECS - Electrical Engineering","degree_department":null,"school":null,"contributors":["Mehregany, Mehran"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009","date_published":"2009","updated_at":"2026-11-26T03:18:00Z","subjects":["Biomedical Research","Electrical Engineering","bioMEMS","Deep Brain Stimulation","internal electrode","MEM","microfabrication","DBS"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1244061398","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1244061398","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1244061398","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1244061398","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Mehregany, Mehran"]},{"key":"dc:creator","label":"Author","values":["Lin, Chia-Hua"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","Electrical Engineering","bioMEMS","Deep Brain Stimulation","internal electrode","MEM","microfabrication","DBS"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1244061398"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This work presents a novel 4-sided, 16-channel deep brain stimulation electrode with a flexible extension lead for connectivity with pulse generation electronics. The 3-dimensional electrode enables steering the current field circumferentially. The electrode is fabricated in pieces by microfabrication techniques; the pieces are then assembled mechanically, after which the lead is connected. The electrode is modeled by finite element analysis and tested in vitro to validate the design concept, i.e., targeted stimulation. With monopolar and bipolar configurations, the electric potential in front of the activated site is at least five times larger than that on the other not-activated sides within a 3 mm radius. The resistance of each channel is also measured. Finally, a pull test is performed to evaluate the mechanical strength of the epoxy used to attach the lead to the electrode. The samples withstood a force of 8.66 g at a 60° angle, thus exhibiting high robustness."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.70","6.27 MB"]},{"key":"dc:title","label":"Title","values":["A Microfabricated Deep Brain Stimulation Electrode"]}]}],"canonical_facts":{"dc:contributor":["Mehregany, Mehran"],"dc:creator":["Lin, Chia-Hua"],"dc:date":["2009"],"dc:description":["This work presents a novel 4-sided, 16-channel deep brain stimulation electrode with a flexible extension lead for connectivity with pulse generation electronics. The 3-dimensional electrode enables steering the current field circumferentially. The electrode is fabricated in pieces by microfabrication techniques; the pieces are then assembled mechanically, after which the lead is connected. The electrode is modeled by finite element analysis and tested in vitro to validate the design concept, i.e., targeted stimulation. With monopolar and bipolar configurations, the electric potential in front of the activated site is at least five times larger than that on the other not-activated sides within a 3 mm radius. The resistance of each channel is also measured. Finally, a pull test is performed to evaluate the mechanical strength of the epoxy used to attach the lead to the electrode. The samples withstood a force of 8.66 g at a 60° angle, thus exhibiting high robustness."],"dc:format":["application/pdf","p.70","6.27 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1244061398"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","Electrical Engineering","bioMEMS","Deep Brain Stimulation","internal electrode","MEM","microfabrication","DBS"],"dc:title":["A Microfabricated Deep Brain Stimulation Electrode"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:18:00Z"}