{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1244237964"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1244237964","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"An Experimental Investigation of Silicone-to-Metal Bond Strength in Composite Space Docking System Seals","abstract":"The National Aeronautics and Space Administration (NASA) is currently developing a new universal docking mechanism for future space exploration missions calledthe Low Impact Docking System (LIDS). In order to successfully mate two pressurizedvehicles or structures in space, advanced seals are required at the interface to preventthe loss of breathable air to vacuum. The leading candidate LIDS main interface sealdesign is a composite assembly of silicone elastomer seal bulbs permanently moldedinto grooves in an electroless nickel-plated aluminum retainer. A composite seal of thestyle being developed has not been proven in a docking role in the history of mannedspaceflight. High adhesive loads on the seal bulbs during undocking could potentiallyovercome the strength of the molded bond between the elastomer and the metalretainer. Bond failure would jeopardize the operation of the seal and docking port,and orbital debris could be liberated. The strength of the silicone-to-metal bond is acritical consideration for the new system, especially due to the presence of small areasof disbond created by the molding process. In the work presented herein, silicone-to-metal bonds of subscale seal specimens with different sizes of intentional disbondare destructively tensile tested. Tension is applied either uniformly on the entireseal circumference or locally in a single circumferential location. Bond failure due touniform tension produces a wide scatter of observable failure modes and measuredload-displacement behaviors. Although the ideal failure mode for the silicone-to-metal bond is 100% cohesive failure of the material, the highest observed cohesionamount is 20% of bond area for the uniform loading condition. Localized tensionproduces failure either as immediate tearing of the elastomer material outside thebond region or as complete peel-out of the seal bulb in one piece. In intentionallyflawed specimens, neither load case considered shows a correlation between disbondsize and bond strength.","abstract_html":"The National Aeronautics and Space Administration (NASA) is currently developing a new universal docking mechanism for future space exploration missions calledthe Low Impact Docking System (LIDS). In order to successfully mate two pressurizedvehicles or structures in space, advanced seals are required at the interface to preventthe loss of breathable air to vacuum. The leading candidate LIDS main interface sealdesign is a composite assembly of silicone elastomer seal bulbs permanently moldedinto grooves in an electroless nickel-plated aluminum retainer. A composite seal of thestyle being developed has not been proven in a docking role in the history of mannedspaceflight. High adhesive loads on the seal bulbs during undocking could potentiallyovercome the strength of the molded bond between the elastomer and the metalretainer. Bond failure would jeopardize the operation of the seal and docking port,and orbital debris could be liberated. The strength of the silicone-to-metal bond is acritical consideration for the new system, especially due to the presence of small areasof disbond created by the molding process. In the work presented herein, silicone-to-metal bonds of subscale seal specimens with different sizes of intentional disbondare destructively tensile tested. Tension is applied either uniformly on the entireseal circumference or locally in a single circumferential location. Bond failure due touniform tension produces a wide scatter of observable failure modes and measuredload-displacement behaviors. Although the ideal failure mode for the silicone-to-metal bond is 100% cohesive failure of the material, the highest observed cohesionamount is 20% of bond area for the uniform loading condition. Localized tensionproduces failure either as immediate tearing of the elastomer material outside thebond region or as complete peel-out of the seal bulb in one piece. In intentionallyflawed specimens, neither load case considered shows a correlation between disbondsize and bond strength.","abstract_has_math":false,"creators":["Conrad, Mason Christian"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":["Prahl, Joseph"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-08-03","date_published":"2009-08-03","updated_at":"2026-11-26T03:18:00Z","subjects":["Aerospace Materials","Engineering","Mechanical Engineering","Polymers","silicone","bond strength","seal","Orion"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1244237964","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1244237964","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1244237964","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1244237964","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Prahl, Joseph"]},{"key":"dc:creator","label":"Author","values":["Conrad, Mason Christian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009-08-03"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Aerospace Materials","Engineering","Mechanical Engineering","Polymers","silicone","bond strength","seal","Orion"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1244237964"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The National Aeronautics and Space Administration (NASA) is currently developing a new universal docking mechanism for future space exploration missions calledthe Low Impact Docking System (LIDS). In order to successfully mate two pressurizedvehicles or structures in space, advanced seals are required at the interface to preventthe loss of breathable air to vacuum. The leading candidate LIDS main interface sealdesign is a composite assembly of silicone elastomer seal bulbs permanently moldedinto grooves in an electroless nickel-plated aluminum retainer. A composite seal of thestyle being developed has not been proven in a docking role in the history of mannedspaceflight. High adhesive loads on the seal bulbs during undocking could potentiallyovercome the strength of the molded bond between the elastomer and the metalretainer. Bond failure would jeopardize the operation of the seal and docking port,and orbital debris could be liberated. The strength of the silicone-to-metal bond is acritical consideration for the new system, especially due to the presence of small areasof disbond created by the molding process. In the work presented herein, silicone-to-metal bonds of subscale seal specimens with different sizes of intentional disbondare destructively tensile tested. Tension is applied either uniformly on the entireseal circumference or locally in a single circumferential location. Bond failure due touniform tension produces a wide scatter of observable failure modes and measuredload-displacement behaviors. Although the ideal failure mode for the silicone-to-metal bond is 100% cohesive failure of the material, the highest observed cohesionamount is 20% of bond area for the uniform loading condition. Localized tensionproduces failure either as immediate tearing of the elastomer material outside thebond region or as complete peel-out of the seal bulb in one piece. In intentionallyflawed specimens, neither load case considered shows a correlation between disbondsize and bond strength."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.80","3.41 MB"]},{"key":"dc:title","label":"Title","values":["An Experimental Investigation of Silicone-to-Metal Bond Strength in Composite Space Docking System Seals"]}]}],"canonical_facts":{"dc:contributor":["Prahl, Joseph"],"dc:creator":["Conrad, Mason Christian"],"dc:date":["2009-08-03"],"dc:description":["The National Aeronautics and Space Administration (NASA) is currently developing a new universal docking mechanism for future space exploration missions calledthe Low Impact Docking System (LIDS). In order to successfully mate two pressurizedvehicles or structures in space, advanced seals are required at the interface to preventthe loss of breathable air to vacuum. The leading candidate LIDS main interface sealdesign is a composite assembly of silicone elastomer seal bulbs permanently moldedinto grooves in an electroless nickel-plated aluminum retainer. A composite seal of thestyle being developed has not been proven in a docking role in the history of mannedspaceflight. High adhesive loads on the seal bulbs during undocking could potentiallyovercome the strength of the molded bond between the elastomer and the metalretainer. Bond failure would jeopardize the operation of the seal and docking port,and orbital debris could be liberated. The strength of the silicone-to-metal bond is acritical consideration for the new system, especially due to the presence of small areasof disbond created by the molding process. In the work presented herein, silicone-to-metal bonds of subscale seal specimens with different sizes of intentional disbondare destructively tensile tested. Tension is applied either uniformly on the entireseal circumference or locally in a single circumferential location. Bond failure due touniform tension produces a wide scatter of observable failure modes and measuredload-displacement behaviors. Although the ideal failure mode for the silicone-to-metal bond is 100% cohesive failure of the material, the highest observed cohesionamount is 20% of bond area for the uniform loading condition. Localized tensionproduces failure either as immediate tearing of the elastomer material outside thebond region or as complete peel-out of the seal bulb in one piece. In intentionallyflawed specimens, neither load case considered shows a correlation between disbondsize and bond strength."],"dc:format":["application/pdf","p.80","3.41 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1244237964"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Aerospace Materials","Engineering","Mechanical Engineering","Polymers","silicone","bond strength","seal","Orion"],"dc:title":["An Experimental Investigation of Silicone-to-Metal Bond Strength in Composite Space Docking System Seals"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:18:00Z"}