{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1257182345"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1257182345","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"The Longitudinal Analysis of Silicone Hydrogel Contact Lens Study","abstract":"The Longitudinal Analysis of Silicone Hydrogel Contact Lens Study (LASH Study) was a prospective cohort study of silicone hydrogel contact lens wearers who slept in their lenses for up to 29 consecutive nights (30 days) of continuous wear, with monthly disposal. Two hundred five healthy myopic or hyperopic patients with minimal or no astigmatism and no contraindications to continuous wear lens use were followed for 1 year. The primary outcome measure was the time to development of a corneal infiltrative event as defined by slit lamp findings and patient symptoms. Survival analysis techniques were used to assess key predictor variables as potential risk factors. The main exposure of interest was corneal staining followed by bacterial contamination of study lenses. Bacterial contamination was found to be common with continuous wear use of silicone hydrogel lenses and the primary risk factor for development of a corneal infiltrative event. Corneal staining was not associated with the development of a corneal infiltrative event. Alteration of the protective mucus layer of the tear film as evidenced by mucin balls trapped behind the lens was found to play a protective role. This information will be helpful for practitioners as they select and monitor patients for this mode of lens wear, and for manufacturers as they design future generations of contact lenses.","abstract_html":"The Longitudinal Analysis of Silicone Hydrogel Contact Lens Study (LASH Study) was a prospective cohort study of silicone hydrogel contact lens wearers who slept in their lenses for up to 29 consecutive nights (30 days) of continuous wear, with monthly disposal. Two hundred five healthy myopic or hyperopic patients with minimal or no astigmatism and no contraindications to continuous wear lens use were followed for 1 year. The primary outcome measure was the time to development of a corneal infiltrative event as defined by slit lamp findings and patient symptoms. Survival analysis techniques were used to assess key predictor variables as potential risk factors. The main exposure of interest was corneal staining followed by bacterial contamination of study lenses. Bacterial contamination was found to be common with continuous wear use of silicone hydrogel lenses and the primary risk factor for development of a corneal infiltrative event. Corneal staining was not associated with the development of a corneal infiltrative event. Alteration of the protective mucus layer of the tear film as evidenced by mucin balls trapped behind the lens was found to play a protective role. This information will be helpful for practitioners as they select and monitor patients for this mode of lens wear, and for manufacturers as they design future generations of contact lenses.","abstract_has_math":false,"creators":["Szczotka-Flynn, Loretta B."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Epidemiology and Biostatistics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Rimm, Alfred"],"committee_members":[],"year":2010,"date_issued":"2010-01-23","date_published":"2010-01-23","updated_at":"2026-11-27T04:14:38Z","subjects":["Epidemiology","Health Care","Microbiology","Ophthalmology","contact lens","corneal infiltrative events","contact lens microbial contamination"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1257182345","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1257182345","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1257182345","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1257182345","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Rimm, Alfred"]},{"key":"dc:creator","label":"Author","values":["Szczotka-Flynn, Loretta B."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-01-23"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Epidemiology and Biostatistics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Epidemiology","Health Care","Microbiology","Ophthalmology","contact lens","corneal infiltrative events","contact lens microbial contamination"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1257182345"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The Longitudinal Analysis of Silicone Hydrogel Contact Lens Study (LASH Study) was a prospective cohort study of silicone hydrogel contact lens wearers who slept in their lenses for up to 29 consecutive nights (30 days) of continuous wear, with monthly disposal. Two hundred five healthy myopic or hyperopic patients with minimal or no astigmatism and no contraindications to continuous wear lens use were followed for 1 year. The primary outcome measure was the time to development of a corneal infiltrative event as defined by slit lamp findings and patient symptoms. Survival analysis techniques were used to assess key predictor variables as potential risk factors. The main exposure of interest was corneal staining followed by bacterial contamination of study lenses. Bacterial contamination was found to be common with continuous wear use of silicone hydrogel lenses and the primary risk factor for development of a corneal infiltrative event. Corneal staining was not associated with the development of a corneal infiltrative event. Alteration of the protective mucus layer of the tear film as evidenced by mucin balls trapped behind the lens was found to play a protective role. This information will be helpful for practitioners as they select and monitor patients for this mode of lens wear, and for manufacturers as they design future generations of contact lenses."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1.27 MB"]},{"key":"dc:title","label":"Title","values":["The Longitudinal Analysis of Silicone Hydrogel Contact Lens Study"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Rimm, Alfred"],"dc:creator":["Szczotka-Flynn, Loretta B."],"dc:date":["2010-01-23"],"dc:description":["The Longitudinal Analysis of Silicone Hydrogel Contact Lens Study (LASH Study) was a prospective cohort study of silicone hydrogel contact lens wearers who slept in their lenses for up to 29 consecutive nights (30 days) of continuous wear, with monthly disposal. Two hundred five healthy myopic or hyperopic patients with minimal or no astigmatism and no contraindications to continuous wear lens use were followed for 1 year. The primary outcome measure was the time to development of a corneal infiltrative event as defined by slit lamp findings and patient symptoms. Survival analysis techniques were used to assess key predictor variables as potential risk factors. The main exposure of interest was corneal staining followed by bacterial contamination of study lenses. Bacterial contamination was found to be common with continuous wear use of silicone hydrogel lenses and the primary risk factor for development of a corneal infiltrative event. Corneal staining was not associated with the development of a corneal infiltrative event. Alteration of the protective mucus layer of the tear film as evidenced by mucin balls trapped behind the lens was found to play a protective role. This information will be helpful for practitioners as they select and monitor patients for this mode of lens wear, and for manufacturers as they design future generations of contact lenses."],"dc:format":["application/pdf","1.27 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1257182345"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Epidemiology","Health Care","Microbiology","Ophthalmology","contact lens","corneal infiltrative events","contact lens microbial contamination"],"dc:title":["The Longitudinal Analysis of Silicone Hydrogel Contact Lens Study"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Epidemiology and Biostatistics"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:38Z"}