{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1260218025"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1260218025","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"A Biomechanical Analysis of Ape and Human Thoracic Vertebrae Using Quantitative Computed Tomography Based Finite Element Models","abstract":"Spontaneous vertebral fractures are common among humans, but not observed in apes. Differences in bone structure associated with increased fracture susceptibility among humans remain unclear. Our aim was to determine how vertebral bone compressive strength varies among apes and humans, and how bone loss affects differences in vertebral strength. QCT-based voxel finite element models derived from quantitative computed tomography (QCT) images of the thoracic vertebrae (T8) were created for apes and humans. Human vertebrae showed significantly reduced bone strength relative to apes with similar body mass (p<0.01) and bone mineral content (p<0.01). Bone loss simulations showed no significant differences in the effect of bone loss on strength among species. Our study suggests human vertebrae are weaker than ape vertebrae after accounting for bone mass, but are not more sensitive to age-related bone loss. Our results support the idea weaker vertebral bone contributes to the unique susceptibility of humans to vertebral fractures.","abstract_html":"Spontaneous vertebral fractures are common among humans, but not observed in apes. Differences in bone structure associated with increased fracture susceptibility among humans remain unclear. Our aim was to determine how vertebral bone compressive strength varies among apes and humans, and how bone loss affects differences in vertebral strength. QCT-based voxel finite element models derived from quantitative computed tomography (QCT) images of the thoracic vertebrae (T8) were created for apes and humans. Human vertebrae showed significantly reduced bone strength relative to apes with similar body mass (p&lt;0.01) and bone mineral content (p&lt;0.01). Bone loss simulations showed no significant differences in the effect of bone loss on strength among species. Our study suggests human vertebrae are weaker than ape vertebrae after accounting for bone mass, but are not more sensitive to age-related bone loss. Our results support the idea weaker vertebral bone contributes to the unique susceptibility of humans to vertebral fractures.","abstract_has_math":false,"creators":["Loomis, David Arthur"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Hernandez, Chris"],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009","date_published":"2009","updated_at":"2026-11-27T04:14:38Z","subjects":["Mechanical Engineering","Vertebrae","Finite Element","Thoracic","Ape","Human"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1260218025","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1260218025","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1260218025","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1260218025","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hernandez, Chris"]},{"key":"dc:creator","label":"Author","values":["Loomis, David Arthur"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","Vertebrae","Finite Element","Thoracic","Ape","Human"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1260218025"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Spontaneous vertebral fractures are common among humans, but not observed in apes. Differences in bone structure associated with increased fracture susceptibility among humans remain unclear. Our aim was to determine how vertebral bone compressive strength varies among apes and humans, and how bone loss affects differences in vertebral strength. QCT-based voxel finite element models derived from quantitative computed tomography (QCT) images of the thoracic vertebrae (T8) were created for apes and humans. Human vertebrae showed significantly reduced bone strength relative to apes with similar body mass (p<0.01) and bone mineral content (p<0.01). Bone loss simulations showed no significant differences in the effect of bone loss on strength among species. Our study suggests human vertebrae are weaker than ape vertebrae after accounting for bone mass, but are not more sensitive to age-related bone loss. Our results support the idea weaker vertebral bone contributes to the unique susceptibility of humans to vertebral fractures."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.41","1.04 MB"]},{"key":"dc:title","label":"Title","values":["A Biomechanical Analysis of Ape and Human Thoracic Vertebrae Using Quantitative Computed Tomography Based Finite Element Models"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hernandez, Chris"],"dc:creator":["Loomis, David Arthur"],"dc:date":["2009"],"dc:description":["Spontaneous vertebral fractures are common among humans, but not observed in apes. Differences in bone structure associated with increased fracture susceptibility among humans remain unclear. Our aim was to determine how vertebral bone compressive strength varies among apes and humans, and how bone loss affects differences in vertebral strength. QCT-based voxel finite element models derived from quantitative computed tomography (QCT) images of the thoracic vertebrae (T8) were created for apes and humans. Human vertebrae showed significantly reduced bone strength relative to apes with similar body mass (p<0.01) and bone mineral content (p<0.01). Bone loss simulations showed no significant differences in the effect of bone loss on strength among species. Our study suggests human vertebrae are weaker than ape vertebrae after accounting for bone mass, but are not more sensitive to age-related bone loss. Our results support the idea weaker vertebral bone contributes to the unique susceptibility of humans to vertebral fractures."],"dc:format":["application/pdf","p.41","1.04 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1260218025"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","Vertebrae","Finite Element","Thoracic","Ape","Human"],"dc:title":["A Biomechanical Analysis of Ape and Human Thoracic Vertebrae Using Quantitative Computed Tomography Based Finite Element Models"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:38Z"}