{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1269970809"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1269970809","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Tension and Flex Fatigue Behavior of Small Diameter Wires for Biomedical Applications","abstract":"The mechanical behavior of small (e.g. 51 um to 510 um) diameter wires used in the biomedical industry has been evaluated in tension and flex bending fatigue at room temperature. 35NLT and 35NLT-DFT-41Ag composite wires exhibited yield/UTS/%RA of 1,651 MPa/2,069 MPa/76.6% and 809 MPa/1,358 MPa/68.3%,respectively. Nitinol (i.e. NiTi) compositions exhibiting different degrees of superelastic behavior exhibited a strain-rate dependent plateau stress/total recoverable strain/%RA in the range 320 MPa-450 MPa/12%/57%-67% and 480MPa/10%/53%-62% for GAC Sentalloy and 3M Unitek SE Orthoform II, respectively. Fully reversed flex bending fatigue was conducted in air over a range of cyclic strains at 1 Hz to establish both the high-cycle and low-cycle fatigue regimes. The fatigue behavior was modeled using the Coffin-Manson-Basquin approach.","abstract_html":"The mechanical behavior of small (e.g. 51 um to 510 um) diameter wires used in the biomedical industry has been evaluated in tension and flex bending fatigue at room temperature. 35NLT and 35NLT-DFT-41Ag composite wires exhibited yield/UTS/%RA of 1,651 MPa/2,069 MPa/76.6% and 809 MPa/1,358 MPa/68.3%,respectively. Nitinol (i.e. NiTi) compositions exhibiting different degrees of superelastic behavior exhibited a strain-rate dependent plateau stress/total recoverable strain/%RA in the range 320 MPa-450 MPa/12%/57%-67% and 480MPa/10%/53%-62% for GAC Sentalloy and 3M Unitek SE Orthoform II, respectively. Fully reversed flex bending fatigue was conducted in air over a range of cyclic strains at 1 Hz to establish both the high-cycle and low-cycle fatigue regimes. The fatigue behavior was modeled using the Coffin-Manson-Basquin approach.","abstract_has_math":false,"creators":["Benini, Brian J."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"Materials Science and Engineering","degree_department":null,"school":null,"contributors":["Lewandowski, John"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-05-17","date_published":"2010-05-17","updated_at":"2026-11-26T03:18:15Z","subjects":["Biomedical Research","Engineering","Experiments","Materials Science","Mechanical Engineering","Fatigue","Nitinol","NiTi","Coffin","Manson","Basquin"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1269970809","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1269970809","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1269970809","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1269970809","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Lewandowski, John"]},{"key":"dc:creator","label":"Author","values":["Benini, Brian J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-05-17"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Materials Science and Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","Engineering","Experiments","Materials Science","Mechanical Engineering","Fatigue","Nitinol","NiTi","Coffin","Manson","Basquin"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1269970809"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The mechanical behavior of small (e.g. 51 um to 510 um) diameter wires used in the biomedical industry has been evaluated in tension and flex bending fatigue at room temperature. 35NLT and 35NLT-DFT-41Ag composite wires exhibited yield/UTS/%RA of 1,651 MPa/2,069 MPa/76.6% and 809 MPa/1,358 MPa/68.3%,respectively. Nitinol (i.e. NiTi) compositions exhibiting different degrees of superelastic behavior exhibited a strain-rate dependent plateau stress/total recoverable strain/%RA in the range 320 MPa-450 MPa/12%/57%-67% and 480MPa/10%/53%-62% for GAC Sentalloy and 3M Unitek SE Orthoform II, respectively. Fully reversed flex bending fatigue was conducted in air over a range of cyclic strains at 1 Hz to establish both the high-cycle and low-cycle fatigue regimes. The fatigue behavior was modeled using the Coffin-Manson-Basquin approach."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.153","14.09 MB"]},{"key":"dc:title","label":"Title","values":["Tension and Flex Fatigue Behavior of Small Diameter Wires for Biomedical Applications"]}]}],"canonical_facts":{"dc:contributor":["Lewandowski, John"],"dc:creator":["Benini, Brian J."],"dc:date":["2010-05-17"],"dc:description":["The mechanical behavior of small (e.g. 51 um to 510 um) diameter wires used in the biomedical industry has been evaluated in tension and flex bending fatigue at room temperature. 35NLT and 35NLT-DFT-41Ag composite wires exhibited yield/UTS/%RA of 1,651 MPa/2,069 MPa/76.6% and 809 MPa/1,358 MPa/68.3%,respectively. Nitinol (i.e. NiTi) compositions exhibiting different degrees of superelastic behavior exhibited a strain-rate dependent plateau stress/total recoverable strain/%RA in the range 320 MPa-450 MPa/12%/57%-67% and 480MPa/10%/53%-62% for GAC Sentalloy and 3M Unitek SE Orthoform II, respectively. Fully reversed flex bending fatigue was conducted in air over a range of cyclic strains at 1 Hz to establish both the high-cycle and low-cycle fatigue regimes. The fatigue behavior was modeled using the Coffin-Manson-Basquin approach."],"dc:format":["application/pdf","p.153","14.09 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1269970809"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","Engineering","Experiments","Materials Science","Mechanical Engineering","Fatigue","Nitinol","NiTi","Coffin","Manson","Basquin"],"dc:title":["Tension and Flex Fatigue Behavior of Small Diameter Wires for Biomedical Applications"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Materials Science and Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:18:15Z"}