{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1270498159"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1270498159","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"DESIGN AND FABRICATION OF A MICROFLUIDIC ELECTROCHEMICAL PH-STAT","abstract":"Conventional pH-stats use titration to add acid or base solution to control sample pH. This technique is impractical for small volume samples because fluidic addition leads to dilution. The goal of this work is to produce a microfluidic electrochemical pH-stat, which utilizes water electrolysis for hydrogen/hydroxyl ion generation. This technique does not induce volume change and can be precisely controlled and measured to determine reaction rates. The device consists of a PDMS-based microchannel that is sandwiched between two glass substrates. The glass substrates support microfabricated electrodes for current injection and pH sensing. Fabrication of the pH-stat utilizes a novel vacuum-assisted micromolding process capable of producing microfluidic channels while maintaining substrate and electrode surface integrity. The pH-stat analyzes two microliters of fluid, uses capillary flow for fluid transport, and ion diffusion as the mixing mechanism. Preliminary evaluation with a sample containing pH-dye shows successful fluid transport, pH modification, and ion diffusion.","abstract_html":"Conventional pH-stats use titration to add acid or base solution to control sample pH. This technique is impractical for small volume samples because fluidic addition leads to dilution. The goal of this work is to produce a microfluidic electrochemical pH-stat, which utilizes water electrolysis for hydrogen/hydroxyl ion generation. This technique does not induce volume change and can be precisely controlled and measured to determine reaction rates. The device consists of a PDMS-based microchannel that is sandwiched between two glass substrates. The glass substrates support microfabricated electrodes for current injection and pH sensing. Fabrication of the pH-stat utilizes a novel vacuum-assisted micromolding process capable of producing microfluidic channels while maintaining substrate and electrode surface integrity. The pH-stat analyzes two microliters of fluid, uses capillary flow for fluid transport, and ion diffusion as the mixing mechanism. Preliminary evaluation with a sample containing pH-dye shows successful fluid transport, pH modification, and ion diffusion.","abstract_has_math":false,"creators":["Stanton, John W."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EECS - Electrical Engineering","degree_department":null,"school":null,"contributors":["Zorman, Christian"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-05-17","date_published":"2010-05-17","updated_at":"2026-11-26T03:18:15Z","subjects":["Electrical Engineering","PDMS","electrochemical pH-stat","microfabrication","glass-PDMS-glass"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1270498159","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1270498159","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1270498159","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1270498159","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Zorman, Christian"]},{"key":"dc:creator","label":"Author","values":["Stanton, John W."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-05-17"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering","PDMS","electrochemical pH-stat","microfabrication","glass-PDMS-glass"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1270498159"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Conventional pH-stats use titration to add acid or base solution to control sample pH. This technique is impractical for small volume samples because fluidic addition leads to dilution. The goal of this work is to produce a microfluidic electrochemical pH-stat, which utilizes water electrolysis for hydrogen/hydroxyl ion generation. This technique does not induce volume change and can be precisely controlled and measured to determine reaction rates. The device consists of a PDMS-based microchannel that is sandwiched between two glass substrates. The glass substrates support microfabricated electrodes for current injection and pH sensing. Fabrication of the pH-stat utilizes a novel vacuum-assisted micromolding process capable of producing microfluidic channels while maintaining substrate and electrode surface integrity. The pH-stat analyzes two microliters of fluid, uses capillary flow for fluid transport, and ion diffusion as the mixing mechanism. Preliminary evaluation with a sample containing pH-dye shows successful fluid transport, pH modification, and ion diffusion."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","1.95 MB"]},{"key":"dc:title","label":"Title","values":["DESIGN AND FABRICATION OF A MICROFLUIDIC ELECTROCHEMICAL PH-STAT"]}]}],"canonical_facts":{"dc:contributor":["Zorman, Christian"],"dc:creator":["Stanton, John W."],"dc:date":["2010-05-17"],"dc:description":["Conventional pH-stats use titration to add acid or base solution to control sample pH. This technique is impractical for small volume samples because fluidic addition leads to dilution. The goal of this work is to produce a microfluidic electrochemical pH-stat, which utilizes water electrolysis for hydrogen/hydroxyl ion generation. This technique does not induce volume change and can be precisely controlled and measured to determine reaction rates. The device consists of a PDMS-based microchannel that is sandwiched between two glass substrates. The glass substrates support microfabricated electrodes for current injection and pH sensing. Fabrication of the pH-stat utilizes a novel vacuum-assisted micromolding process capable of producing microfluidic channels while maintaining substrate and electrode surface integrity. The pH-stat analyzes two microliters of fluid, uses capillary flow for fluid transport, and ion diffusion as the mixing mechanism. Preliminary evaluation with a sample containing pH-dye shows successful fluid transport, pH modification, and ion diffusion."],"dc:format":["application/pdf","1.95 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1270498159"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Electrical Engineering","PDMS","electrochemical pH-stat","microfabrication","glass-PDMS-glass"],"dc:title":["DESIGN AND FABRICATION OF A MICROFLUIDIC ELECTROCHEMICAL PH-STAT"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:18:15Z"}