{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1279679194"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1279679194","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Insertion Point Eccentricity Controlled Ankle Mechanism in Conjunction with Functional Electric Stimulation","abstract":"The goal of this project was to have a prototype of an active Ankle Foot Orthosis (AFO) that would help control and assist plantar flexion and orsiflexion with a single motor acting as an antagonistic pair of uscles. To control the amount and direction of the torque about the ankle Insertion Point Eccentricity Control (IPEC), a way of moving astored energy, was used. The device, a heavily altered Ankle Foot Orthosis (AFO), would help control and assist plantar flexion and dorsi-flexion. A challenge was also to keep the weight added to the standard AFO at no more than one pound. After initial testing, it was seen that the IPEC AFO is able to provide 3.51 ± .05 Nm about the ankle in dorsi-flexion and 3.88 ± .15 Nm in plantar flexion with a spring modulus of 17.76 lbs/inch and an initial tension of 17.24 lbs. The torque was found to be sufficient to move the foot during walking. The design’s most important objective was to be advantageous and safe for the user. The user would range from a Spinal Cord Injury (SCI) subject to a stroke subject with drop-foot or other disorder concerning the ankle. The IPEC AFO cycles quickly enough for an SCI FES user. The IPEC AFO is an improvement because it leverages energy stored in the spring to reduce power required by the motor.","abstract_html":"The goal of this project was to have a prototype of an active Ankle Foot Orthosis (AFO) that would help control and assist plantar flexion and orsiflexion with a single motor acting as an antagonistic pair of uscles. To control the amount and direction of the torque about the ankle Insertion Point Eccentricity Control (IPEC), a way of moving astored energy, was used. The device, a heavily altered Ankle Foot Orthosis (AFO), would help control and assist plantar flexion and dorsi-flexion. A challenge was also to keep the weight added to the standard AFO at no more than one pound. After initial testing, it was seen that the IPEC AFO is able to provide 3.51 ± .05 Nm about the ankle in dorsi-flexion and 3.88 ± .15 Nm in plantar flexion with a spring modulus of 17.76 lbs/inch and an initial tension of 17.24 lbs. The torque was found to be sufficient to move the foot during walking. The design’s most important objective was to be advantageous and safe for the user. The user would range from a Spinal Cord Injury (SCI) subject to a stroke subject with drop-foot or other disorder concerning the ankle. The IPEC AFO cycles quickly enough for an SCI FES user. The IPEC AFO is an improvement because it leverages energy stored in the spring to reduce power required by the motor.","abstract_has_math":false,"creators":["Polinkovsky, Arkady A."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":["Quinn, Roger"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-11-26T03:18:31Z","subjects":["Biomedical Research","Engineering","Mechanical Engineering","Functional Electric Stimulation","Ankle Foot Orthosis","Spinal Cord Injury"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1279679194","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1279679194","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1279679194","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1279679194","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Quinn, Roger"]},{"key":"dc:creator","label":"Author","values":["Polinkovsky, Arkady A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","Engineering","Mechanical Engineering","Functional Electric Stimulation","Ankle Foot Orthosis","Spinal Cord Injury"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1279679194"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The goal of this project was to have a prototype of an active Ankle Foot Orthosis (AFO) that would help control and assist plantar flexion and orsiflexion with a single motor acting as an antagonistic pair of uscles. To control the amount and direction of the torque about the ankle Insertion Point Eccentricity Control (IPEC), a way of moving astored energy, was used. The device, a heavily altered Ankle Foot Orthosis (AFO), would help control and assist plantar flexion and dorsi-flexion. A challenge was also to keep the weight added to the standard AFO at no more than one pound. After initial testing, it was seen that the IPEC AFO is able to provide 3.51 ± .05 Nm about the ankle in dorsi-flexion and 3.88 ± .15 Nm in plantar flexion with a spring modulus of 17.76 lbs/inch and an initial tension of 17.24 lbs. The torque was found to be sufficient to move the foot during walking. The design’s most important objective was to be advantageous and safe for the user. The user would range from a Spinal Cord Injury (SCI) subject to a stroke subject with drop-foot or other disorder concerning the ankle. The IPEC AFO cycles quickly enough for an SCI FES user. The IPEC AFO is an improvement because it leverages energy stored in the spring to reduce power required by the motor."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.66","6.38 MB"]},{"key":"dc:title","label":"Title","values":["Insertion Point Eccentricity Controlled Ankle Mechanism in Conjunction with Functional Electric Stimulation"]}]}],"canonical_facts":{"dc:contributor":["Quinn, Roger"],"dc:creator":["Polinkovsky, Arkady A."],"dc:date":["2010"],"dc:description":["The goal of this project was to have a prototype of an active Ankle Foot Orthosis (AFO) that would help control and assist plantar flexion and orsiflexion with a single motor acting as an antagonistic pair of uscles. To control the amount and direction of the torque about the ankle Insertion Point Eccentricity Control (IPEC), a way of moving astored energy, was used. The device, a heavily altered Ankle Foot Orthosis (AFO), would help control and assist plantar flexion and dorsi-flexion. A challenge was also to keep the weight added to the standard AFO at no more than one pound. After initial testing, it was seen that the IPEC AFO is able to provide 3.51 ± .05 Nm about the ankle in dorsi-flexion and 3.88 ± .15 Nm in plantar flexion with a spring modulus of 17.76 lbs/inch and an initial tension of 17.24 lbs. The torque was found to be sufficient to move the foot during walking. The design’s most important objective was to be advantageous and safe for the user. The user would range from a Spinal Cord Injury (SCI) subject to a stroke subject with drop-foot or other disorder concerning the ankle. The IPEC AFO cycles quickly enough for an SCI FES user. The IPEC AFO is an improvement because it leverages energy stored in the spring to reduce power required by the motor."],"dc:format":["application/pdf","p.66","6.38 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1279679194"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","Engineering","Mechanical Engineering","Functional Electric Stimulation","Ankle Foot Orthosis","Spinal Cord Injury"],"dc:title":["Insertion Point Eccentricity Controlled Ankle Mechanism in Conjunction with Functional Electric Stimulation"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:18:31Z"}