{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1279943930"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1279943930","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Rapid and Quantitative MRI of Chemical Exchange and Magnetization Transfer","abstract":"Chemical Exchange Saturation Transfer (CEST) and Magnetization Transfer (MT) techniques provide unique and potentially quantitative contrast mechanisms in multiple MRI applications. However, the in vivo implementation of these techniques has been limited by the relatively slow MRI acquisition techniques, especially on high field MRI scanners. A new, rapid CEST-FISP (CEST - Fast Imaging with Steady-state free Precession) technique was developed to provide sensitive CEST contrast in approximately 20 seconds. In this study at 7T with in vitro bovine glycogen samples and initial in vivo results in a rat liver, the CEST-FISP technique was shown to provide equivalent CEST sensitivity in comparison to a conventional CEST spin echo acquisition with a 50-fold reduction in acquisition time. The sensitivity of the CEST-FISP technique was also shown to be dependent on k-space encoding with centric k-space encoding providing a 30-40% increase in CEST sensitivity relative to linear encoding for 256 or more k-space lines. Overall, the CEST-FISP acquisition technique provides a rapid and sensitive imaging platform with the potential to provide quantitative CEST and MT imaging data.","abstract_html":"Chemical Exchange Saturation Transfer (CEST) and Magnetization Transfer (MT) techniques provide unique and potentially quantitative contrast mechanisms in multiple MRI applications. However, the in vivo implementation of these techniques has been limited by the relatively slow MRI acquisition techniques, especially on high field MRI scanners. A new, rapid CEST-FISP (CEST - Fast Imaging with Steady-state free Precession) technique was developed to provide sensitive CEST contrast in approximately 20 seconds. In this study at 7T with in vitro bovine glycogen samples and initial in vivo results in a rat liver, the CEST-FISP technique was shown to provide equivalent CEST sensitivity in comparison to a conventional CEST spin echo acquisition with a 50-fold reduction in acquisition time. The sensitivity of the CEST-FISP technique was also shown to be dependent on k-space encoding with centric k-space encoding providing a 30-40% increase in CEST sensitivity relative to linear encoding for 256 or more k-space lines. Overall, the CEST-FISP acquisition technique provides a rapid and sensitive imaging platform with the potential to provide quantitative CEST and MT imaging data.","abstract_has_math":false,"creators":["Shah, Tejas Jatin"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Flask, Christopher"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-07-30","date_published":"2010-07-30","updated_at":"2026-11-27T04:14:50Z","subjects":["Health Care","CEST","MRI","Pulse Sequence"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1279943930","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1279943930","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1279943930","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1279943930","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Flask, Christopher"]},{"key":"dc:creator","label":"Author","values":["Shah, Tejas Jatin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-07-30"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Health Care","CEST","MRI","Pulse Sequence"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1279943930"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Chemical Exchange Saturation Transfer (CEST) and Magnetization Transfer (MT) techniques provide unique and potentially quantitative contrast mechanisms in multiple MRI applications. However, the in vivo implementation of these techniques has been limited by the relatively slow MRI acquisition techniques, especially on high field MRI scanners. A new, rapid CEST-FISP (CEST - Fast Imaging with Steady-state free Precession) technique was developed to provide sensitive CEST contrast in approximately 20 seconds. In this study at 7T with in vitro bovine glycogen samples and initial in vivo results in a rat liver, the CEST-FISP technique was shown to provide equivalent CEST sensitivity in comparison to a conventional CEST spin echo acquisition with a 50-fold reduction in acquisition time. The sensitivity of the CEST-FISP technique was also shown to be dependent on k-space encoding with centric k-space encoding providing a 30-40% increase in CEST sensitivity relative to linear encoding for 256 or more k-space lines. Overall, the CEST-FISP acquisition technique provides a rapid and sensitive imaging platform with the potential to provide quantitative CEST and MT imaging data."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.42","1.4 MB"]},{"key":"dc:title","label":"Title","values":["Rapid and Quantitative MRI of Chemical Exchange and Magnetization Transfer"]}]}],"canonical_facts":{"dc:contributor.advisor":["Flask, Christopher"],"dc:creator":["Shah, Tejas Jatin"],"dc:date":["2010-07-30"],"dc:description":["Chemical Exchange Saturation Transfer (CEST) and Magnetization Transfer (MT) techniques provide unique and potentially quantitative contrast mechanisms in multiple MRI applications. However, the in vivo implementation of these techniques has been limited by the relatively slow MRI acquisition techniques, especially on high field MRI scanners. A new, rapid CEST-FISP (CEST - Fast Imaging with Steady-state free Precession) technique was developed to provide sensitive CEST contrast in approximately 20 seconds. In this study at 7T with in vitro bovine glycogen samples and initial in vivo results in a rat liver, the CEST-FISP technique was shown to provide equivalent CEST sensitivity in comparison to a conventional CEST spin echo acquisition with a 50-fold reduction in acquisition time. The sensitivity of the CEST-FISP technique was also shown to be dependent on k-space encoding with centric k-space encoding providing a 30-40% increase in CEST sensitivity relative to linear encoding for 256 or more k-space lines. Overall, the CEST-FISP acquisition technique provides a rapid and sensitive imaging platform with the potential to provide quantitative CEST and MT imaging data."],"dc:format":["application/pdf","p.42","1.4 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1279943930"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Health Care","CEST","MRI","Pulse Sequence"],"dc:title":["Rapid and Quantitative MRI of Chemical Exchange and Magnetization Transfer"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:50Z"}