{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1281404517"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1281404517","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"The Suppression of Selected Acoustic Noise Frequencies in MRI","abstract":"Problems due to Magnetic Resonance Imaging (MRI) acoustic noise have long been an important concern, both in research and clinical applications. A study is made of certain dominant frequencies in the acoustic noise spectrum of the MRI system. Motivated by both spring and string ideas, we investigate whether the contributions to the sound from certain frequencies can be cancelled by the appropriate the gradient pulse sequence design. Ideas for cancelling these frequencies are investigated by carrying out theoretical string calculations. The MRI gradient assembly is modeled as a string and the gradient pulse sequences as a driving force for that string. Analytical results are obtained with different input gradient pulses including boxcars, trapezoids, and multiple trapezoids, along with special “quadratic” pulses. Pulse trains composed of repetitions of these pulse structures are studied. For comparison and to test these ideas, both simulations and experiments are carried out to verify our analytical results for the cancellations of selected frequency peaks. The idea that vibrations resulting from an impulsive force associated with a ramping up of a gradient pulse are shown to be cancelled immediately upon the application of another impulsive force coming from the subsequent appropriately timed ramping down of that pulse is verified both by simulations and experiments. A general approach to suppression of multiple-frequency contributions involving a series of gradient pulses with variable timings is given for the cancellations between pairs of impulse forces. The various examples investigated with string analytics and simulations and the associated MRI experiments are a physical embodiments of general time-invariant linear response theory. The present study also provides a foundation to explain results in previous papers on this subject. The method suggests that a variety of pulse profiles and timing combinations can be used to attenuate important contributions to the acoustic output spectrum.","abstract_html":"Problems due to Magnetic Resonance Imaging (MRI) acoustic noise have long been an important concern, both in research and clinical applications. A study is made of certain dominant frequencies in the acoustic noise spectrum of the MRI system. Motivated by both spring and string ideas, we investigate whether the contributions to the sound from certain frequencies can be cancelled by the appropriate the gradient pulse sequence design. Ideas for cancelling these frequencies are investigated by carrying out theoretical string calculations. The MRI gradient assembly is modeled as a string and the gradient pulse sequences as a driving force for that string. Analytical results are obtained with different input gradient pulses including boxcars, trapezoids, and multiple trapezoids, along with special “quadratic” pulses. Pulse trains composed of repetitions of these pulse structures are studied. For comparison and to test these ideas, both simulations and experiments are carried out to verify our analytical results for the cancellations of selected frequency peaks. The idea that vibrations resulting from an impulsive force associated with a ramping up of a gradient pulse are shown to be cancelled immediately upon the application of another impulsive force coming from the subsequent appropriately timed ramping down of that pulse is verified both by simulations and experiments. A general approach to suppression of multiple-frequency contributions involving a series of gradient pulses with variable timings is given for the cancellations between pairs of impulse forces. The various examples investigated with string analytics and simulations and the associated MRI experiments are a physical embodiments of general time-invariant linear response theory. The present study also provides a foundation to explain results in previous papers on this subject. The method suggests that a variety of pulse profiles and timing combinations can be used to attenuate important contributions to the acoustic output spectrum.","abstract_has_math":false,"creators":["Shou, Xingxian"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":["Brown, Robert"],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011","date_published":"2011","updated_at":"2026-11-27T04:14:50Z","subjects":["Acoustics","Biomedical Research","Physics","Acoustic noise","MRI system","Vibrating string","Gradient pulse optimization"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1281404517","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1281404517","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1281404517","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1281404517","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Brown, Robert"]},{"key":"dc:creator","label":"Author","values":["Shou, Xingxian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Acoustics","Biomedical Research","Physics","Acoustic noise","MRI system","Vibrating string","Gradient pulse optimization"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1281404517"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Problems due to Magnetic Resonance Imaging (MRI) acoustic noise have long been an important concern, both in research and clinical applications. A study is made of certain dominant frequencies in the acoustic noise spectrum of the MRI system. Motivated by both spring and string ideas, we investigate whether the contributions to the sound from certain frequencies can be cancelled by the appropriate the gradient pulse sequence design. Ideas for cancelling these frequencies are investigated by carrying out theoretical string calculations. The MRI gradient assembly is modeled as a string and the gradient pulse sequences as a driving force for that string. Analytical results are obtained with different input gradient pulses including boxcars, trapezoids, and multiple trapezoids, along with special “quadratic” pulses. Pulse trains composed of repetitions of these pulse structures are studied. For comparison and to test these ideas, both simulations and experiments are carried out to verify our analytical results for the cancellations of selected frequency peaks. The idea that vibrations resulting from an impulsive force associated with a ramping up of a gradient pulse are shown to be cancelled immediately upon the application of another impulsive force coming from the subsequent appropriately timed ramping down of that pulse is verified both by simulations and experiments. A general approach to suppression of multiple-frequency contributions involving a series of gradient pulses with variable timings is given for the cancellations between pairs of impulse forces. The various examples investigated with string analytics and simulations and the associated MRI experiments are a physical embodiments of general time-invariant linear response theory. The present study also provides a foundation to explain results in previous papers on this subject. The method suggests that a variety of pulse profiles and timing combinations can be used to attenuate important contributions to the acoustic output spectrum."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.148","1.94 MB"]},{"key":"dc:title","label":"Title","values":["The Suppression of Selected Acoustic Noise Frequencies in MRI"]}]}],"canonical_facts":{"dc:contributor.advisor":["Brown, Robert"],"dc:creator":["Shou, Xingxian"],"dc:date":["2011"],"dc:description":["Problems due to Magnetic Resonance Imaging (MRI) acoustic noise have long been an important concern, both in research and clinical applications. A study is made of certain dominant frequencies in the acoustic noise spectrum of the MRI system. Motivated by both spring and string ideas, we investigate whether the contributions to the sound from certain frequencies can be cancelled by the appropriate the gradient pulse sequence design. Ideas for cancelling these frequencies are investigated by carrying out theoretical string calculations. The MRI gradient assembly is modeled as a string and the gradient pulse sequences as a driving force for that string. Analytical results are obtained with different input gradient pulses including boxcars, trapezoids, and multiple trapezoids, along with special “quadratic” pulses. Pulse trains composed of repetitions of these pulse structures are studied. For comparison and to test these ideas, both simulations and experiments are carried out to verify our analytical results for the cancellations of selected frequency peaks. The idea that vibrations resulting from an impulsive force associated with a ramping up of a gradient pulse are shown to be cancelled immediately upon the application of another impulsive force coming from the subsequent appropriately timed ramping down of that pulse is verified both by simulations and experiments. A general approach to suppression of multiple-frequency contributions involving a series of gradient pulses with variable timings is given for the cancellations between pairs of impulse forces. The various examples investigated with string analytics and simulations and the associated MRI experiments are a physical embodiments of general time-invariant linear response theory. The present study also provides a foundation to explain results in previous papers on this subject. The method suggests that a variety of pulse profiles and timing combinations can be used to attenuate important contributions to the acoustic output spectrum."],"dc:format":["application/pdf","p.148","1.94 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1281404517"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Acoustics","Biomedical Research","Physics","Acoustic noise","MRI system","Vibrating string","Gradient pulse optimization"],"dc:title":["The Suppression of Selected Acoustic Noise Frequencies in MRI"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:50Z"}