{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1290287480"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1290287480","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"A CEST MRI METHOD TO MEASURE pH","abstract":"Tumor pH is an important biomarker in cancer. In the following chapters an approach to measure pH by Chemical Exchange Saturation Transfer (CEST) MRI is described. Chapter 1 presents and introduction to molecular imaging, the importance of tumor pH and existing methods of pH measurement by various imaging modalities. Chapter 2 describes the characterization of a PARACEST MRI contrast agent, Yb-DO3A-oAA, for pH measurement. The pH measurement is independent of concentration and T1sat relaxation times, and covers a wider pH measurement range than alternative methods. A new method for fitting PARACEST spectra is shown. Chapter 3 demonstrates the self calibrating nature of CEST MRI with the contrast agent, Yb-DO3A-oAA-TML-ester, to detect esterase enzyme activity in solution and in cell culture media by generating an enzyme-responsive CEST effect that was compared with a control CEST effect from the same agent. In Chapter 4, a new MRI method was developed to simplify MRI acquisition of CEST spectra. Arrayed CEST-FISP and the parameters of this method were optimized for use with PARACEST agents. The arrayed CEST-FISP pulse program simplifies acquisition setup and subsequent analysis, and has strong potential to increase CEST experimental throughput that will facilitate future discoveries. Chapter 5 translates Yb-DO3A-oAA from in vitro to in vivo use to measure pH in a MDA-MB-231 tumor model and mouse muscle. The pharmacodynamics of Yb-DO3A-oAA are investigated and the fitting algorithm described in Chapter 2 is extended to in vivo tissues.","abstract_html":"Tumor pH is an important biomarker in cancer. In the following chapters an approach to measure pH by Chemical Exchange Saturation Transfer (CEST) MRI is described. Chapter 1 presents and introduction to molecular imaging, the importance of tumor pH and existing methods of pH measurement by various imaging modalities. Chapter 2 describes the characterization of a PARACEST MRI contrast agent, Yb-DO3A-oAA, for pH measurement. The pH measurement is independent of concentration and T1sat relaxation times, and covers a wider pH measurement range than alternative methods. A new method for fitting PARACEST spectra is shown. Chapter 3 demonstrates the self calibrating nature of CEST MRI with the contrast agent, Yb-DO3A-oAA-TML-ester, to detect esterase enzyme activity in solution and in cell culture media by generating an enzyme-responsive CEST effect that was compared with a control CEST effect from the same agent. In Chapter 4, a new MRI method was developed to simplify MRI acquisition of CEST spectra. Arrayed CEST-FISP and the parameters of this method were optimized for use with PARACEST agents. The arrayed CEST-FISP pulse program simplifies acquisition setup and subsequent analysis, and has strong potential to increase CEST experimental throughput that will facilitate future discoveries. Chapter 5 translates Yb-DO3A-oAA from in vitro to in vivo use to measure pH in a MDA-MB-231 tumor model and mouse muscle. The pharmacodynamics of Yb-DO3A-oAA are investigated and the fitting algorithm described in Chapter 2 is extended to in vivo tissues.","abstract_has_math":false,"creators":["Sheth, Vipul Ravindra"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Lu, Zheng-Rong","Pagel, Mark"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011","date_published":"2011","updated_at":"2026-11-26T03:18:31Z","subjects":["Biomedical Engineering","MRI","CEST","PARACEST","Paramagnetic","Saturation","pH","Magnetic Resonance","Chemical Exchange Saturation Transfer","Magnetic Resonance Imaging","Lanthanide"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1290287480","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1290287480","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1290287480","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1290287480","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Lu, Zheng-Rong","Pagel, Mark"]},{"key":"dc:creator","label":"Author","values":["Sheth, Vipul Ravindra"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","MRI","CEST","PARACEST","Paramagnetic","Saturation","pH","Magnetic Resonance","Chemical Exchange Saturation Transfer","Magnetic Resonance Imaging","Lanthanide"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1290287480"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Tumor pH is an important biomarker in cancer. In the following chapters an approach to measure pH by Chemical Exchange Saturation Transfer (CEST) MRI is described. Chapter 1 presents and introduction to molecular imaging, the importance of tumor pH and existing methods of pH measurement by various imaging modalities. Chapter 2 describes the characterization of a PARACEST MRI contrast agent, Yb-DO3A-oAA, for pH measurement. The pH measurement is independent of concentration and T1sat relaxation times, and covers a wider pH measurement range than alternative methods. A new method for fitting PARACEST spectra is shown. Chapter 3 demonstrates the self calibrating nature of CEST MRI with the contrast agent, Yb-DO3A-oAA-TML-ester, to detect esterase enzyme activity in solution and in cell culture media by generating an enzyme-responsive CEST effect that was compared with a control CEST effect from the same agent. In Chapter 4, a new MRI method was developed to simplify MRI acquisition of CEST spectra. Arrayed CEST-FISP and the parameters of this method were optimized for use with PARACEST agents. The arrayed CEST-FISP pulse program simplifies acquisition setup and subsequent analysis, and has strong potential to increase CEST experimental throughput that will facilitate future discoveries. Chapter 5 translates Yb-DO3A-oAA from in vitro to in vivo use to measure pH in a MDA-MB-231 tumor model and mouse muscle. The pharmacodynamics of Yb-DO3A-oAA are investigated and the fitting algorithm described in Chapter 2 is extended to in vivo tissues."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.169","3.69 MB"]},{"key":"dc:title","label":"Title","values":["A CEST MRI METHOD TO MEASURE pH"]}]}],"canonical_facts":{"dc:contributor":["Lu, Zheng-Rong","Pagel, Mark"],"dc:creator":["Sheth, Vipul Ravindra"],"dc:date":["2011"],"dc:description":["Tumor pH is an important biomarker in cancer. In the following chapters an approach to measure pH by Chemical Exchange Saturation Transfer (CEST) MRI is described. Chapter 1 presents and introduction to molecular imaging, the importance of tumor pH and existing methods of pH measurement by various imaging modalities. Chapter 2 describes the characterization of a PARACEST MRI contrast agent, Yb-DO3A-oAA, for pH measurement. The pH measurement is independent of concentration and T1sat relaxation times, and covers a wider pH measurement range than alternative methods. A new method for fitting PARACEST spectra is shown. Chapter 3 demonstrates the self calibrating nature of CEST MRI with the contrast agent, Yb-DO3A-oAA-TML-ester, to detect esterase enzyme activity in solution and in cell culture media by generating an enzyme-responsive CEST effect that was compared with a control CEST effect from the same agent. In Chapter 4, a new MRI method was developed to simplify MRI acquisition of CEST spectra. Arrayed CEST-FISP and the parameters of this method were optimized for use with PARACEST agents. The arrayed CEST-FISP pulse program simplifies acquisition setup and subsequent analysis, and has strong potential to increase CEST experimental throughput that will facilitate future discoveries. Chapter 5 translates Yb-DO3A-oAA from in vitro to in vivo use to measure pH in a MDA-MB-231 tumor model and mouse muscle. The pharmacodynamics of Yb-DO3A-oAA are investigated and the fitting algorithm described in Chapter 2 is extended to in vivo tissues."],"dc:format":["application/pdf","p.169","3.69 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1290287480"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","MRI","CEST","PARACEST","Paramagnetic","Saturation","pH","Magnetic Resonance","Chemical Exchange Saturation Transfer","Magnetic Resonance Imaging","Lanthanide"],"dc:title":["A CEST MRI METHOD TO MEASURE pH"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:18:31Z"}