{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1291389492"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1291389492","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Extracting Command Signals From Peripheral Nerve Recordings","abstract":"<p>Despite great advances in many areas of medical technology over the past 20 years, the challenge of providing amputees a prosthesis with the intuitive control and functionality of a natural limb remains. Improvements in materials have made them lighter and stronger, but little headway has been made in giving amputees more functionality and easier control. Recently, this problem has been addressed on a number of fronts, including electrical control from the muscles of the residual limb, or techniques involving multi-contact neural interfaces and muscular reinnervation. While these techniquesrepresent important future directions for the field, they have not been shown to provide the robust and intuitive control signals required to take full advantage of a dexterous hand prosthesis.</p><p>Nerve cuff electrodes represent a less invasive alternative to penetrating array electrodes. Individual neurons in peripheral nerves are separated into fascicles, which are loosely spatially organized based on the location they innervate. This thesis leverages the spatial organization in order to separate and recover fascicular signals. Simulations of a human femoral nerve finite element model were used to validate the approach, and demonstrate source localization to 180±170μm. The electrode and recording system built to implement in vivo experiments provided a 2μVrms noise floor on 16-channels, allowing the reconstruction accuracy to be measured at R<sup>2</sup>=0.81±0.08 for large synchronized neural responses in an in-vivo rabbit sciatic nerve model. Smaller, pseudo-spontaneous signals generated with high-frequency sinusoidal stimulation were separated with crosstalk of 23±13%, and found to transmit 4±2 bits-per-second-per-source. These recovered fascicular sources correlate to individual muscle activities (even if the muscles have been amputated) and their activity may be used to drive corresponding motors in a limb prosthesis. Beyond prosthetic limbs, this same technique is applicable for recording and localizing sources within any large nerve trunk and may be useful for many otherartificial sensors and organs.</p>","abstract_html":"&lt;p&gt;Despite great advances in many areas of medical technology over the past 20 years, the challenge of providing amputees a prosthesis with the intuitive control and functionality of a natural limb remains. Improvements in materials have made them lighter and stronger, but little headway has been made in giving amputees more functionality and easier control. Recently, this problem has been addressed on a number of fronts, including electrical control from the muscles of the residual limb, or techniques involving multi-contact neural interfaces and muscular reinnervation. While these techniquesrepresent important future directions for the field, they have not been shown to provide the robust and intuitive control signals required to take full advantage of a dexterous hand prosthesis.&lt;/p&gt;&lt;p&gt;Nerve cuff electrodes represent a less invasive alternative to penetrating array electrodes. Individual neurons in peripheral nerves are separated into fascicles, which are loosely spatially organized based on the location they innervate. This thesis leverages the spatial organization in order to separate and recover fascicular signals. Simulations of a human femoral nerve finite element model were used to validate the approach, and demonstrate source localization to 180±170μm. The electrode and recording system built to implement in vivo experiments provided a 2μVrms noise floor on 16-channels, allowing the reconstruction accuracy to be measured at R&lt;sup&gt;2&lt;/sup&gt;=0.81±0.08 for large synchronized neural responses in an in-vivo rabbit sciatic nerve model. Smaller, pseudo-spontaneous signals generated with high-frequency sinusoidal stimulation were separated with crosstalk of 23±13%, and found to transmit 4±2 bits-per-second-per-source. These recovered fascicular sources correlate to individual muscle activities (even if the muscles have been amputated) and their activity may be used to drive corresponding motors in a limb prosthesis. Beyond prosthetic limbs, this same technique is applicable for recording and localizing sources within any large nerve trunk and may be useful for many otherartificial sensors and organs.&lt;/p&gt;","abstract_has_math":false,"creators":["Wodlinger, Brian"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Durand, Dominique"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-11-26T03:18:31Z","subjects":["Biomedical Engineering","Biomedical Research","Engineering","Health Care","Medicine","Neurobiology","Neurosciences","Rehabilitation","source localization","nerve recording","flat interface nerve electrode","PNS","Beamforming","Spatial Filters","selective recording","cuff electrode"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1291389492","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1291389492","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1291389492","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1291389492","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Durand, Dominique"]},{"key":"dc:creator","label":"Author","values":["Wodlinger, Brian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Biomedical Research","Engineering","Health Care","Medicine","Neurobiology","Neurosciences","Rehabilitation","source localization","nerve recording","flat interface nerve electrode","PNS","Beamforming","Spatial Filters","selective recording","cuff electrode"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1291389492"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Despite great advances in many areas of medical technology over the past 20 years, the challenge of providing amputees a prosthesis with the intuitive control and functionality of a natural limb remains. Improvements in materials have made them lighter and stronger, but little headway has been made in giving amputees more functionality and easier control. Recently, this problem has been addressed on a number of fronts, including electrical control from the muscles of the residual limb, or techniques involving multi-contact neural interfaces and muscular reinnervation. While these techniquesrepresent important future directions for the field, they have not been shown to provide the robust and intuitive control signals required to take full advantage of a dexterous hand prosthesis.</p><p>Nerve cuff electrodes represent a less invasive alternative to penetrating array electrodes. Individual neurons in peripheral nerves are separated into fascicles, which are loosely spatially organized based on the location they innervate. This thesis leverages the spatial organization in order to separate and recover fascicular signals. Simulations of a human femoral nerve finite element model were used to validate the approach, and demonstrate source localization to 180±170μm. The electrode and recording system built to implement in vivo experiments provided a 2μVrms noise floor on 16-channels, allowing the reconstruction accuracy to be measured at R<sup>2</sup>=0.81±0.08 for large synchronized neural responses in an in-vivo rabbit sciatic nerve model. Smaller, pseudo-spontaneous signals generated with high-frequency sinusoidal stimulation were separated with crosstalk of 23±13%, and found to transmit 4±2 bits-per-second-per-source. These recovered fascicular sources correlate to individual muscle activities (even if the muscles have been amputated) and their activity may be used to drive corresponding motors in a limb prosthesis. Beyond prosthetic limbs, this same technique is applicable for recording and localizing sources within any large nerve trunk and may be useful for many otherartificial sensors and organs.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","2.64 MB"]},{"key":"dc:title","label":"Title","values":["Extracting Command Signals From Peripheral Nerve Recordings"]}]}],"canonical_facts":{"dc:contributor":["Durand, Dominique"],"dc:creator":["Wodlinger, Brian"],"dc:date":["2010"],"dc:description":["<p>Despite great advances in many areas of medical technology over the past 20 years, the challenge of providing amputees a prosthesis with the intuitive control and functionality of a natural limb remains. Improvements in materials have made them lighter and stronger, but little headway has been made in giving amputees more functionality and easier control. Recently, this problem has been addressed on a number of fronts, including electrical control from the muscles of the residual limb, or techniques involving multi-contact neural interfaces and muscular reinnervation. While these techniquesrepresent important future directions for the field, they have not been shown to provide the robust and intuitive control signals required to take full advantage of a dexterous hand prosthesis.</p><p>Nerve cuff electrodes represent a less invasive alternative to penetrating array electrodes. Individual neurons in peripheral nerves are separated into fascicles, which are loosely spatially organized based on the location they innervate. This thesis leverages the spatial organization in order to separate and recover fascicular signals. Simulations of a human femoral nerve finite element model were used to validate the approach, and demonstrate source localization to 180±170μm. The electrode and recording system built to implement in vivo experiments provided a 2μVrms noise floor on 16-channels, allowing the reconstruction accuracy to be measured at R<sup>2</sup>=0.81±0.08 for large synchronized neural responses in an in-vivo rabbit sciatic nerve model. Smaller, pseudo-spontaneous signals generated with high-frequency sinusoidal stimulation were separated with crosstalk of 23±13%, and found to transmit 4±2 bits-per-second-per-source. These recovered fascicular sources correlate to individual muscle activities (even if the muscles have been amputated) and their activity may be used to drive corresponding motors in a limb prosthesis. Beyond prosthetic limbs, this same technique is applicable for recording and localizing sources within any large nerve trunk and may be useful for many otherartificial sensors and organs.</p>"],"dc:format":["application/pdf","2.64 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1291389492"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Biomedical Research","Engineering","Health Care","Medicine","Neurobiology","Neurosciences","Rehabilitation","source localization","nerve recording","flat interface nerve electrode","PNS","Beamforming","Spatial Filters","selective recording","cuff electrode"],"dc:title":["Extracting Command Signals From Peripheral Nerve Recordings"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:18:31Z"}