{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1301325325"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1301325325","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Particle Concentration Measurements in a Centrifugal Slurry Pump Using an A-Scan Ultrasound Technique","abstract":"In the design of slurry transport equipment used in a variety of industries, the effects of solid particle concentration on hydraulic performance and wear need to be considered. An ultrasound A-mode imaging method has been developed to obtain local particle concentration measurements in slurry flows. Acoustic properties of slurry flows including velocity, backscatter, and attenuation as a function of volume fraction of solid particles, are examined in this study using various transducers. The most suitable transducer is selected to obtain concentration measurements in slurry flows. The technique is used to obtain concentration profiles in a homogeneous (vertical flow) and a non-homogeneous (horizontal flow) slurry flow of soda lime glass beads (195 µm diameter) and water through a one inch diameter loop with solid particle concentrations ranging from 1-10 % by volume. For horizontal flow, profiles are obtained for average flow velocities of 1.2, 2.0, 3.0, and 3.5 m/s. The algorithm developed utilizes acoustic backscatter and attenuation measurements obtained from the homogeneous loop as calibration data in order to obtain concentration profiles in other (i.e. non-homogenous) flow regimes. A computational study using FLUENT is performed and a comparison is made with the experimental results. A reasonable agreement between the experimental and computational results is observed in the one inch pipe. Following transducer selection and refinement and validation of the technique, it is employed to obtain local particle concentration measurements at multiple locations within the casing of a centrifugal slurry pump. A comparison is made between the experimental results and computational results using a two phase Eulerian-Eulerian finite element model. Computational fluid dynamics (CFD) and Experimental results at locations F→I share the same trends and relative patterns for differing locations but have substantial differences in magnitude. The CFD consistently shows higher concentration magnitudes than the experimental data. These differences are most likely a result of an un-matched casing inlet concentration boundary condition.","abstract_html":"In the design of slurry transport equipment used in a variety of industries, the effects of solid particle concentration on hydraulic performance and wear need to be considered. An ultrasound A-mode imaging method has been developed to obtain local particle concentration measurements in slurry flows. Acoustic properties of slurry flows including velocity, backscatter, and attenuation as a function of volume fraction of solid particles, are examined in this study using various transducers. The most suitable transducer is selected to obtain concentration measurements in slurry flows. The technique is used to obtain concentration profiles in a homogeneous (vertical flow) and a non-homogeneous (horizontal flow) slurry flow of soda lime glass beads (195 µm diameter) and water through a one inch diameter loop with solid particle concentrations ranging from 1-10 % by volume. For horizontal flow, profiles are obtained for average flow velocities of 1.2, 2.0, 3.0, and 3.5 m/s. The algorithm developed utilizes acoustic backscatter and attenuation measurements obtained from the homogeneous loop as calibration data in order to obtain concentration profiles in other (i.e. non-homogenous) flow regimes. A computational study using FLUENT is performed and a comparison is made with the experimental results. A reasonable agreement between the experimental and computational results is observed in the one inch pipe. Following transducer selection and refinement and validation of the technique, it is employed to obtain local particle concentration measurements at multiple locations within the casing of a centrifugal slurry pump. A comparison is made between the experimental results and computational results using a two phase Eulerian-Eulerian finite element model. Computational fluid dynamics (CFD) and Experimental results at locations F→I share the same trends and relative patterns for differing locations but have substantial differences in magnitude. The CFD consistently shows higher concentration magnitudes than the experimental data. These differences are most likely a result of an un-matched casing inlet concentration boundary condition.","abstract_has_math":false,"creators":["Furlan, John Michael"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Kadambi, Jaikrishnan"],"committee_members":[],"year":2011,"date_issued":"2011-04-18","date_published":"2011-04-18","updated_at":"2026-11-27T04:14:50Z","subjects":["Mechanical Engineering","slurry flow","ultrasound","particle concentration measurement","Centrifugal Pump"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1301325325","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1301325325","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1301325325","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1301325325","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Kadambi, Jaikrishnan"]},{"key":"dc:creator","label":"Author","values":["Furlan, John Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-04-18"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","slurry flow","ultrasound","particle concentration measurement","Centrifugal Pump"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1301325325"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In the design of slurry transport equipment used in a variety of industries, the effects of solid particle concentration on hydraulic performance and wear need to be considered. An ultrasound A-mode imaging method has been developed to obtain local particle concentration measurements in slurry flows. Acoustic properties of slurry flows including velocity, backscatter, and attenuation as a function of volume fraction of solid particles, are examined in this study using various transducers. The most suitable transducer is selected to obtain concentration measurements in slurry flows. The technique is used to obtain concentration profiles in a homogeneous (vertical flow) and a non-homogeneous (horizontal flow) slurry flow of soda lime glass beads (195 µm diameter) and water through a one inch diameter loop with solid particle concentrations ranging from 1-10 % by volume. For horizontal flow, profiles are obtained for average flow velocities of 1.2, 2.0, 3.0, and 3.5 m/s. The algorithm developed utilizes acoustic backscatter and attenuation measurements obtained from the homogeneous loop as calibration data in order to obtain concentration profiles in other (i.e. non-homogenous) flow regimes. A computational study using FLUENT is performed and a comparison is made with the experimental results. A reasonable agreement between the experimental and computational results is observed in the one inch pipe. Following transducer selection and refinement and validation of the technique, it is employed to obtain local particle concentration measurements at multiple locations within the casing of a centrifugal slurry pump. A comparison is made between the experimental results and computational results using a two phase Eulerian-Eulerian finite element model. Computational fluid dynamics (CFD) and Experimental results at locations F→I share the same trends and relative patterns for differing locations but have substantial differences in magnitude. The CFD consistently shows higher concentration magnitudes than the experimental data. These differences are most likely a result of an un-matched casing inlet concentration boundary condition."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.200","10.98 MB"]},{"key":"dc:title","label":"Title","values":["Particle Concentration Measurements in a Centrifugal Slurry Pump Using an A-Scan Ultrasound Technique"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Kadambi, Jaikrishnan"],"dc:creator":["Furlan, John Michael"],"dc:date":["2011-04-18"],"dc:description":["In the design of slurry transport equipment used in a variety of industries, the effects of solid particle concentration on hydraulic performance and wear need to be considered. An ultrasound A-mode imaging method has been developed to obtain local particle concentration measurements in slurry flows. Acoustic properties of slurry flows including velocity, backscatter, and attenuation as a function of volume fraction of solid particles, are examined in this study using various transducers. The most suitable transducer is selected to obtain concentration measurements in slurry flows. The technique is used to obtain concentration profiles in a homogeneous (vertical flow) and a non-homogeneous (horizontal flow) slurry flow of soda lime glass beads (195 µm diameter) and water through a one inch diameter loop with solid particle concentrations ranging from 1-10 % by volume. For horizontal flow, profiles are obtained for average flow velocities of 1.2, 2.0, 3.0, and 3.5 m/s. The algorithm developed utilizes acoustic backscatter and attenuation measurements obtained from the homogeneous loop as calibration data in order to obtain concentration profiles in other (i.e. non-homogenous) flow regimes. A computational study using FLUENT is performed and a comparison is made with the experimental results. A reasonable agreement between the experimental and computational results is observed in the one inch pipe. Following transducer selection and refinement and validation of the technique, it is employed to obtain local particle concentration measurements at multiple locations within the casing of a centrifugal slurry pump. A comparison is made between the experimental results and computational results using a two phase Eulerian-Eulerian finite element model. Computational fluid dynamics (CFD) and Experimental results at locations F→I share the same trends and relative patterns for differing locations but have substantial differences in magnitude. The CFD consistently shows higher concentration magnitudes than the experimental data. These differences are most likely a result of an un-matched casing inlet concentration boundary condition."],"dc:format":["application/pdf","p.200","10.98 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1301325325"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","slurry flow","ultrasound","particle concentration measurement","Centrifugal Pump"],"dc:title":["Particle Concentration Measurements in a Centrifugal Slurry Pump Using an A-Scan Ultrasound Technique"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:50Z"}