{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1301516012"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1301516012","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Multielectrode platform for measuring oxygenation status in multicellular tumor spheroids","abstract":"<p>Heterogeneous oxygen distribution in tumor microenvironment can contribute to therapy failure. Anoxia and severe hypoxia in microregions of solid tumors results in decreased activity of cells or up-regulation of hypoxia linked cell survival mechanisms. These adaptations are in favor of survival and proliferation of hypoxic cells in adverse conditions making them resistant to therapy. Knowledge of oxygen distribution inside tumor biopsies and models along with therapeutic efficacy of drug molecules would be of great value to improve clinical outcomes by personalizing therapy and and in-vitro screening of potential new drug molecules. Current methodologies for oxygen measurement in 3D tissues, based on both optical and electrochemical principles, are restricted to single time point measurements assuming steady state oxygen distributions. Both time- and depth-resolved continuous mapping of oxygen inside tumor tissue models has not been achieved. </p><p>Development and validation of continuous oxygen concentration measurement approach for both 3D multicellular tumor spheroid models and single cells is reported here. A device with an array of gold microdisc electrodes is designed and fabricated using MEMS fabrication techniques. Oxygen concentration profiles inside model spheroids are measured using this device. Dependence of the rate of cellular oxygen consumption on extracellular oxygen concentration is demonstrated from the recorded data by discrete numerical analysis. A continuous model of oxygen concentration considering linearly decreasing consumption rates is developed which improves upon previous models that assume constant rate of consumption. Oxygen concentration of single cells and small cluster of cells is measured using a microring electrode platform. Oxygen consumption of single cell is quantified from the concentration data. </p><p>Single cell processes like multi-drug resistance, metabolism, respiration etc. can be investigated using the microring electrode platform and cumulative tissue effects, also called multi-cellular resistance, in tumor biopsies and models can be investigated using the multielectrode array approach. Information obtained from both approaches combined together provides a comprehensive picture of cancer chemotherapy failure mechanisms. Finally, an interesting design of spatially averaging electrodes is validated for heterogeneous microliter size hemispherical drops. This design can be used for obtaining average concentrations of substances inside our model spheroids.</p>","abstract_html":"&lt;p&gt;Heterogeneous oxygen distribution in tumor microenvironment can contribute to therapy failure. Anoxia and severe hypoxia in microregions of solid tumors results in decreased activity of cells or up-regulation of hypoxia linked cell survival mechanisms. These adaptations are in favor of survival and proliferation of hypoxic cells in adverse conditions making them resistant to therapy. Knowledge of oxygen distribution inside tumor biopsies and models along with therapeutic efficacy of drug molecules would be of great value to improve clinical outcomes by personalizing therapy and and in-vitro screening of potential new drug molecules. Current methodologies for oxygen measurement in 3D tissues, based on both optical and electrochemical principles, are restricted to single time point measurements assuming steady state oxygen distributions. Both time- and depth-resolved continuous mapping of oxygen inside tumor tissue models has not been achieved. &lt;/p&gt;&lt;p&gt;Development and validation of continuous oxygen concentration measurement approach for both 3D multicellular tumor spheroid models and single cells is reported here. A device with an array of gold microdisc electrodes is designed and fabricated using MEMS fabrication techniques. Oxygen concentration profiles inside model spheroids are measured using this device. Dependence of the rate of cellular oxygen consumption on extracellular oxygen concentration is demonstrated from the recorded data by discrete numerical analysis. A continuous model of oxygen concentration considering linearly decreasing consumption rates is developed which improves upon previous models that assume constant rate of consumption. Oxygen concentration of single cells and small cluster of cells is measured using a microring electrode platform. Oxygen consumption of single cell is quantified from the concentration data. &lt;/p&gt;&lt;p&gt;Single cell processes like multi-drug resistance, metabolism, respiration etc. can be investigated using the microring electrode platform and cumulative tissue effects, also called multi-cellular resistance, in tumor biopsies and models can be investigated using the multielectrode array approach. Information obtained from both approaches combined together provides a comprehensive picture of cancer chemotherapy failure mechanisms. Finally, an interesting design of spatially averaging electrodes is validated for heterogeneous microliter size hemispherical drops. This design can be used for obtaining average concentrations of substances inside our model spheroids.&lt;/p&gt;","abstract_has_math":false,"creators":["Sheth, Disha B."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Gratzl, Miklos"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-04-25","date_published":"2011-04-25","updated_at":"2026-11-26T03:18:47Z","subjects":["Biomedical Engineering","Multielectrode","Oxygen consumption","Hypoxia","Multi-cellular resistance","MCR","Multi-drug resistance","MDR","Speroids","Tumor microenvironment"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1301516012","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1301516012","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1301516012","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1301516012","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Gratzl, Miklos"]},{"key":"dc:creator","label":"Author","values":["Sheth, Disha B."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-04-25"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Multielectrode","Oxygen consumption","Hypoxia","Multi-cellular resistance","MCR","Multi-drug resistance","MDR","Speroids","Tumor microenvironment"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1301516012"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Heterogeneous oxygen distribution in tumor microenvironment can contribute to therapy failure. Anoxia and severe hypoxia in microregions of solid tumors results in decreased activity of cells or up-regulation of hypoxia linked cell survival mechanisms. These adaptations are in favor of survival and proliferation of hypoxic cells in adverse conditions making them resistant to therapy. Knowledge of oxygen distribution inside tumor biopsies and models along with therapeutic efficacy of drug molecules would be of great value to improve clinical outcomes by personalizing therapy and and in-vitro screening of potential new drug molecules. Current methodologies for oxygen measurement in 3D tissues, based on both optical and electrochemical principles, are restricted to single time point measurements assuming steady state oxygen distributions. Both time- and depth-resolved continuous mapping of oxygen inside tumor tissue models has not been achieved. </p><p>Development and validation of continuous oxygen concentration measurement approach for both 3D multicellular tumor spheroid models and single cells is reported here. A device with an array of gold microdisc electrodes is designed and fabricated using MEMS fabrication techniques. Oxygen concentration profiles inside model spheroids are measured using this device. Dependence of the rate of cellular oxygen consumption on extracellular oxygen concentration is demonstrated from the recorded data by discrete numerical analysis. A continuous model of oxygen concentration considering linearly decreasing consumption rates is developed which improves upon previous models that assume constant rate of consumption. Oxygen concentration of single cells and small cluster of cells is measured using a microring electrode platform. Oxygen consumption of single cell is quantified from the concentration data. </p><p>Single cell processes like multi-drug resistance, metabolism, respiration etc. can be investigated using the microring electrode platform and cumulative tissue effects, also called multi-cellular resistance, in tumor biopsies and models can be investigated using the multielectrode array approach. Information obtained from both approaches combined together provides a comprehensive picture of cancer chemotherapy failure mechanisms. Finally, an interesting design of spatially averaging electrodes is validated for heterogeneous microliter size hemispherical drops. This design can be used for obtaining average concentrations of substances inside our model spheroids.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.248","2.77 MB"]},{"key":"dc:title","label":"Title","values":["Multielectrode platform for measuring oxygenation status in multicellular tumor spheroids"]}]}],"canonical_facts":{"dc:contributor":["Gratzl, Miklos"],"dc:creator":["Sheth, Disha B."],"dc:date":["2011-04-25"],"dc:description":["<p>Heterogeneous oxygen distribution in tumor microenvironment can contribute to therapy failure. Anoxia and severe hypoxia in microregions of solid tumors results in decreased activity of cells or up-regulation of hypoxia linked cell survival mechanisms. These adaptations are in favor of survival and proliferation of hypoxic cells in adverse conditions making them resistant to therapy. Knowledge of oxygen distribution inside tumor biopsies and models along with therapeutic efficacy of drug molecules would be of great value to improve clinical outcomes by personalizing therapy and and in-vitro screening of potential new drug molecules. Current methodologies for oxygen measurement in 3D tissues, based on both optical and electrochemical principles, are restricted to single time point measurements assuming steady state oxygen distributions. Both time- and depth-resolved continuous mapping of oxygen inside tumor tissue models has not been achieved. </p><p>Development and validation of continuous oxygen concentration measurement approach for both 3D multicellular tumor spheroid models and single cells is reported here. A device with an array of gold microdisc electrodes is designed and fabricated using MEMS fabrication techniques. Oxygen concentration profiles inside model spheroids are measured using this device. Dependence of the rate of cellular oxygen consumption on extracellular oxygen concentration is demonstrated from the recorded data by discrete numerical analysis. A continuous model of oxygen concentration considering linearly decreasing consumption rates is developed which improves upon previous models that assume constant rate of consumption. Oxygen concentration of single cells and small cluster of cells is measured using a microring electrode platform. Oxygen consumption of single cell is quantified from the concentration data. </p><p>Single cell processes like multi-drug resistance, metabolism, respiration etc. can be investigated using the microring electrode platform and cumulative tissue effects, also called multi-cellular resistance, in tumor biopsies and models can be investigated using the multielectrode array approach. Information obtained from both approaches combined together provides a comprehensive picture of cancer chemotherapy failure mechanisms. Finally, an interesting design of spatially averaging electrodes is validated for heterogeneous microliter size hemispherical drops. This design can be used for obtaining average concentrations of substances inside our model spheroids.</p>"],"dc:format":["application/pdf","p.248","2.77 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1301516012"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Multielectrode","Oxygen consumption","Hypoxia","Multi-cellular resistance","MCR","Multi-drug resistance","MDR","Speroids","Tumor microenvironment"],"dc:title":["Multielectrode platform for measuring oxygenation status in multicellular tumor spheroids"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:18:47Z"}