{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1301967862"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1301967862","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Electrochemical Evaluation of Platinum and Diamond Electrodes for Neural Stimulation","abstract":"<p>The stimulating electrode is a vital component of a neural prosthesis since it is in direct contact with tissue. To ensure an electrode maximizes charge injection while avoiding tissue damage, one must understand the electrochemical characteristics of the electrode material. Two electrode materials were studied in this context: platinum, the most common electrode material for neural stimulation; and conductive diamond, a new material that has promising characteristics for neurological applications. Two electrochemical techniques were used: cyclic voltammetry (CV) and a custom system, the Current Pulse – Capacitor Discharge (CP-CD) Method.</p><p>CV of platinum in phosphate-buffered saline (PBS) exhibited electrochemical activity not expected in physiological tissue: platinum reduces or oxidizes the sodium phosphate component of PBS. Diamond did not exhibit such electrochemical activity over its 3-V potential window.</p><p>The reduction of O<sub>2</sub> to superoxide can be damaging to tissue. At a physiological concentration of O<sub>2</sub> in 0.15 M H<sub>2</sub>SO<sub>4</sub>, platinum electrodes reduce O<sub>2</sub> at potentials negative of approximately +0.6 V vs. Ag/AgCl (its open-circuit potential), and diamond electrodes reduce oxygen negative of -1.2 V.</p><p>Contaminant adsorption on an electrode surface can inhibit charge transfer, decreasing its effectiveness at stimulating neural activity. Voltammetry of platinum in the high-organic content Aplysia hemolymph showed significant decreases in current density compared to PBS. CV of diamond in hemolymph indicated some varied electrochemical activity, but no decrease in current densities.</p><p>Since CV is a relatively slow technique, the CP-CD method was developed by our lab to study charge transfer at the fast rates of neural stimulation. Preliminary experiments showed only a fraction of the charge transferred during CV can be transferred during fast pulsing. Therefore, historical estimates of charge injection from CV are significantly overestimated.</p><p>Overall, the O<sub>2</sub> reduction reaction and the organic adsorption issues discovered with platinum may pose limitations in its use for neural stimulation. Diamond’s resistance to O<sub>2</sub> reduction and strong anti-fouling properties make it an attractive electrode material for this application. The experiments performed provide a wealth of information on platinum and diamond electrodes, but also provide a protocol for evaluating any electrode or electrolyte in the context of neural stimulation.</p>","abstract_html":"&lt;p&gt;The stimulating electrode is a vital component of a neural prosthesis since it is in direct contact with tissue. To ensure an electrode maximizes charge injection while avoiding tissue damage, one must understand the electrochemical characteristics of the electrode material. Two electrode materials were studied in this context: platinum, the most common electrode material for neural stimulation; and conductive diamond, a new material that has promising characteristics for neurological applications. Two electrochemical techniques were used: cyclic voltammetry (CV) and a custom system, the Current Pulse – Capacitor Discharge (CP-CD) Method.&lt;/p&gt;&lt;p&gt;CV of platinum in phosphate-buffered saline (PBS) exhibited electrochemical activity not expected in physiological tissue: platinum reduces or oxidizes the sodium phosphate component of PBS. Diamond did not exhibit such electrochemical activity over its 3-V potential window.&lt;/p&gt;&lt;p&gt;The reduction of O&lt;sub&gt;2&lt;/sub&gt; to superoxide can be damaging to tissue. At a physiological concentration of O&lt;sub&gt;2&lt;/sub&gt; in 0.15 M H&lt;sub&gt;2&lt;/sub&gt;SO&lt;sub&gt;4&lt;/sub&gt;, platinum electrodes reduce O&lt;sub&gt;2&lt;/sub&gt; at potentials negative of approximately +0.6 V vs. Ag/AgCl (its open-circuit potential), and diamond electrodes reduce oxygen negative of -1.2 V.&lt;/p&gt;&lt;p&gt;Contaminant adsorption on an electrode surface can inhibit charge transfer, decreasing its effectiveness at stimulating neural activity. Voltammetry of platinum in the high-organic content Aplysia hemolymph showed significant decreases in current density compared to PBS. CV of diamond in hemolymph indicated some varied electrochemical activity, but no decrease in current densities.&lt;/p&gt;&lt;p&gt;Since CV is a relatively slow technique, the CP-CD method was developed by our lab to study charge transfer at the fast rates of neural stimulation. Preliminary experiments showed only a fraction of the charge transferred during CV can be transferred during fast pulsing. Therefore, historical estimates of charge injection from CV are significantly overestimated.&lt;/p&gt;&lt;p&gt;Overall, the O&lt;sub&gt;2&lt;/sub&gt; reduction reaction and the organic adsorption issues discovered with platinum may pose limitations in its use for neural stimulation. Diamond’s resistance to O&lt;sub&gt;2&lt;/sub&gt; reduction and strong anti-fouling properties make it an attractive electrode material for this application. The experiments performed provide a wealth of information on platinum and diamond electrodes, but also provide a protocol for evaluating any electrode or electrolyte in the context of neural stimulation.&lt;/p&gt;","abstract_has_math":false,"creators":["Hudak, Eric Michael"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":["Martin, Heidi B.","Mortimer, J. Thomas"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-04-18","date_published":"2011-04-18","updated_at":"2026-11-26T03:18:47Z","subjects":["Biomedical Engineering","Chemical Engineering","Neurosciences","diamond","platinum","electrochemical","neural stimulation","electrodes","cyclic voltammetry"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1301967862","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1301967862","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1301967862","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1301967862","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Martin, Heidi B.","Mortimer, J. Thomas"]},{"key":"dc:creator","label":"Author","values":["Hudak, Eric Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-04-18"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Chemical Engineering","Neurosciences","diamond","platinum","electrochemical","neural stimulation","electrodes","cyclic voltammetry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1301967862"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>The stimulating electrode is a vital component of a neural prosthesis since it is in direct contact with tissue. To ensure an electrode maximizes charge injection while avoiding tissue damage, one must understand the electrochemical characteristics of the electrode material. Two electrode materials were studied in this context: platinum, the most common electrode material for neural stimulation; and conductive diamond, a new material that has promising characteristics for neurological applications. Two electrochemical techniques were used: cyclic voltammetry (CV) and a custom system, the Current Pulse – Capacitor Discharge (CP-CD) Method.</p><p>CV of platinum in phosphate-buffered saline (PBS) exhibited electrochemical activity not expected in physiological tissue: platinum reduces or oxidizes the sodium phosphate component of PBS. Diamond did not exhibit such electrochemical activity over its 3-V potential window.</p><p>The reduction of O<sub>2</sub> to superoxide can be damaging to tissue. At a physiological concentration of O<sub>2</sub> in 0.15 M H<sub>2</sub>SO<sub>4</sub>, platinum electrodes reduce O<sub>2</sub> at potentials negative of approximately +0.6 V vs. Ag/AgCl (its open-circuit potential), and diamond electrodes reduce oxygen negative of -1.2 V.</p><p>Contaminant adsorption on an electrode surface can inhibit charge transfer, decreasing its effectiveness at stimulating neural activity. Voltammetry of platinum in the high-organic content Aplysia hemolymph showed significant decreases in current density compared to PBS. CV of diamond in hemolymph indicated some varied electrochemical activity, but no decrease in current densities.</p><p>Since CV is a relatively slow technique, the CP-CD method was developed by our lab to study charge transfer at the fast rates of neural stimulation. Preliminary experiments showed only a fraction of the charge transferred during CV can be transferred during fast pulsing. Therefore, historical estimates of charge injection from CV are significantly overestimated.</p><p>Overall, the O<sub>2</sub> reduction reaction and the organic adsorption issues discovered with platinum may pose limitations in its use for neural stimulation. Diamond’s resistance to O<sub>2</sub> reduction and strong anti-fouling properties make it an attractive electrode material for this application. The experiments performed provide a wealth of information on platinum and diamond electrodes, but also provide a protocol for evaluating any electrode or electrolyte in the context of neural stimulation.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.160","7.7 MB"]},{"key":"dc:title","label":"Title","values":["Electrochemical Evaluation of Platinum and Diamond Electrodes for Neural Stimulation"]}]}],"canonical_facts":{"dc:contributor":["Martin, Heidi B.","Mortimer, J. Thomas"],"dc:creator":["Hudak, Eric Michael"],"dc:date":["2011-04-18"],"dc:description":["<p>The stimulating electrode is a vital component of a neural prosthesis since it is in direct contact with tissue. To ensure an electrode maximizes charge injection while avoiding tissue damage, one must understand the electrochemical characteristics of the electrode material. Two electrode materials were studied in this context: platinum, the most common electrode material for neural stimulation; and conductive diamond, a new material that has promising characteristics for neurological applications. Two electrochemical techniques were used: cyclic voltammetry (CV) and a custom system, the Current Pulse – Capacitor Discharge (CP-CD) Method.</p><p>CV of platinum in phosphate-buffered saline (PBS) exhibited electrochemical activity not expected in physiological tissue: platinum reduces or oxidizes the sodium phosphate component of PBS. Diamond did not exhibit such electrochemical activity over its 3-V potential window.</p><p>The reduction of O<sub>2</sub> to superoxide can be damaging to tissue. At a physiological concentration of O<sub>2</sub> in 0.15 M H<sub>2</sub>SO<sub>4</sub>, platinum electrodes reduce O<sub>2</sub> at potentials negative of approximately +0.6 V vs. Ag/AgCl (its open-circuit potential), and diamond electrodes reduce oxygen negative of -1.2 V.</p><p>Contaminant adsorption on an electrode surface can inhibit charge transfer, decreasing its effectiveness at stimulating neural activity. Voltammetry of platinum in the high-organic content Aplysia hemolymph showed significant decreases in current density compared to PBS. CV of diamond in hemolymph indicated some varied electrochemical activity, but no decrease in current densities.</p><p>Since CV is a relatively slow technique, the CP-CD method was developed by our lab to study charge transfer at the fast rates of neural stimulation. Preliminary experiments showed only a fraction of the charge transferred during CV can be transferred during fast pulsing. Therefore, historical estimates of charge injection from CV are significantly overestimated.</p><p>Overall, the O<sub>2</sub> reduction reaction and the organic adsorption issues discovered with platinum may pose limitations in its use for neural stimulation. Diamond’s resistance to O<sub>2</sub> reduction and strong anti-fouling properties make it an attractive electrode material for this application. The experiments performed provide a wealth of information on platinum and diamond electrodes, but also provide a protocol for evaluating any electrode or electrolyte in the context of neural stimulation.</p>"],"dc:format":["application/pdf","p.160","7.7 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1301967862"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Chemical Engineering","Neurosciences","diamond","platinum","electrochemical","neural stimulation","electrodes","cyclic voltammetry"],"dc:title":["Electrochemical Evaluation of Platinum and Diamond Electrodes for Neural Stimulation"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:18:47Z"}