{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1307743446"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1307743446","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Breathing Entrainment and Mechanical Ventilation in Rats","abstract":"Mechanical ventilation is a clinical intervention used to ensure adequate lung inflation for gas exchange and to reduce the work load on the respiratory muscles. Traditionally, continuous mechanical ventilation (CMV) delivers the appropriate gas at a predetermined rate, tidal volume and Inflation:Deflation ratio related to the Inspiration:Expiration (I:E) ratio. While mechanical ventilation save lives, complications occur and these are referred to as Ventilator-Associated Lung Injury (VALI). In addition to VALI, approximately 15% of patients being treated with CMV have trouble weaning from the ventilator. Biologically Variable Ventilation (BVV) has been proposed as a method to reduce VALI and minimize weaning failure. In BVV, ventilatory parameters are altered on a breath-by-breath basis. The physiologic effectiveness of BVV has been studied in animal models and it has the ability to maintain blood oxygenation. This thesis analyzes the effect of CMV and BVV on the formation of concurrent spontaneous breathing patterns, specifically the variability in the bursts of inspiratory motor activity. Variability can be considered as an index of health and well being. Since BVV emulates physiologic variability, hypothesis is that BVV is better than CMV in promoting breathing pattern variability during and following ventilation. A variable ventilatory pattern may address VALI and weaning-related problems. This thesis presents the effect of ventilatory parameters on entrainment of the spontaneous breathing pattern with the ventilator and a comparison of CMV and BVV on linear and non-linear variability measures of the spontaneous breathing pattern during and after ventilation.","abstract_html":"Mechanical ventilation is a clinical intervention used to ensure adequate lung inflation for gas exchange and to reduce the work load on the respiratory muscles. Traditionally, continuous mechanical ventilation (CMV) delivers the appropriate gas at a predetermined rate, tidal volume and Inflation:Deflation ratio related to the Inspiration:Expiration (I:E) ratio. While mechanical ventilation save lives, complications occur and these are referred to as Ventilator-Associated Lung Injury (VALI). In addition to VALI, approximately 15% of patients being treated with CMV have trouble weaning from the ventilator. Biologically Variable Ventilation (BVV) has been proposed as a method to reduce VALI and minimize weaning failure. In BVV, ventilatory parameters are altered on a breath-by-breath basis. The physiologic effectiveness of BVV has been studied in animal models and it has the ability to maintain blood oxygenation. This thesis analyzes the effect of CMV and BVV on the formation of concurrent spontaneous breathing patterns, specifically the variability in the bursts of inspiratory motor activity. Variability can be considered as an index of health and well being. Since BVV emulates physiologic variability, hypothesis is that BVV is better than CMV in promoting breathing pattern variability during and following ventilation. A variable ventilatory pattern may address VALI and weaning-related problems. This thesis presents the effect of ventilatory parameters on entrainment of the spontaneous breathing pattern with the ventilator and a comparison of CMV and BVV on linear and non-linear variability measures of the spontaneous breathing pattern during and after ventilation.","abstract_has_math":false,"creators":["Balaji, Ravishankar"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EECS - System and Control Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Loparo, Kenneth A."],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-06-28","date_published":"2011-06-28","updated_at":"2026-11-27T04:14:50Z","subjects":["Computer Science","Engineering","Medicine","Mechanical ventilator","ventilation","breathing","entrainment"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1307743446","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1307743446","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1307743446","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1307743446","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Loparo, Kenneth A."]},{"key":"dc:creator","label":"Author","values":["Balaji, Ravishankar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-06-28"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - System and Control Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Computer Science","Engineering","Medicine","Mechanical ventilator","ventilation","breathing","entrainment"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1307743446"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Mechanical ventilation is a clinical intervention used to ensure adequate lung inflation for gas exchange and to reduce the work load on the respiratory muscles. Traditionally, continuous mechanical ventilation (CMV) delivers the appropriate gas at a predetermined rate, tidal volume and Inflation:Deflation ratio related to the Inspiration:Expiration (I:E) ratio. While mechanical ventilation save lives, complications occur and these are referred to as Ventilator-Associated Lung Injury (VALI). In addition to VALI, approximately 15% of patients being treated with CMV have trouble weaning from the ventilator. Biologically Variable Ventilation (BVV) has been proposed as a method to reduce VALI and minimize weaning failure. In BVV, ventilatory parameters are altered on a breath-by-breath basis. The physiologic effectiveness of BVV has been studied in animal models and it has the ability to maintain blood oxygenation. This thesis analyzes the effect of CMV and BVV on the formation of concurrent spontaneous breathing patterns, specifically the variability in the bursts of inspiratory motor activity. Variability can be considered as an index of health and well being. Since BVV emulates physiologic variability, hypothesis is that BVV is better than CMV in promoting breathing pattern variability during and following ventilation. A variable ventilatory pattern may address VALI and weaning-related problems. This thesis presents the effect of ventilatory parameters on entrainment of the spontaneous breathing pattern with the ventilator and a comparison of CMV and BVV on linear and non-linear variability measures of the spontaneous breathing pattern during and after ventilation."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.66","5.62 MB"]},{"key":"dc:title","label":"Title","values":["Breathing Entrainment and Mechanical Ventilation in Rats"]}]}],"canonical_facts":{"dc:contributor.advisor":["Loparo, Kenneth A."],"dc:creator":["Balaji, Ravishankar"],"dc:date":["2011-06-28"],"dc:description":["Mechanical ventilation is a clinical intervention used to ensure adequate lung inflation for gas exchange and to reduce the work load on the respiratory muscles. Traditionally, continuous mechanical ventilation (CMV) delivers the appropriate gas at a predetermined rate, tidal volume and Inflation:Deflation ratio related to the Inspiration:Expiration (I:E) ratio. While mechanical ventilation save lives, complications occur and these are referred to as Ventilator-Associated Lung Injury (VALI). In addition to VALI, approximately 15% of patients being treated with CMV have trouble weaning from the ventilator. Biologically Variable Ventilation (BVV) has been proposed as a method to reduce VALI and minimize weaning failure. In BVV, ventilatory parameters are altered on a breath-by-breath basis. The physiologic effectiveness of BVV has been studied in animal models and it has the ability to maintain blood oxygenation. This thesis analyzes the effect of CMV and BVV on the formation of concurrent spontaneous breathing patterns, specifically the variability in the bursts of inspiratory motor activity. Variability can be considered as an index of health and well being. Since BVV emulates physiologic variability, hypothesis is that BVV is better than CMV in promoting breathing pattern variability during and following ventilation. A variable ventilatory pattern may address VALI and weaning-related problems. This thesis presents the effect of ventilatory parameters on entrainment of the spontaneous breathing pattern with the ventilator and a comparison of CMV and BVV on linear and non-linear variability measures of the spontaneous breathing pattern during and after ventilation."],"dc:format":["application/pdf","p.66","5.62 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1307743446"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Computer Science","Engineering","Medicine","Mechanical ventilator","ventilation","breathing","entrainment"],"dc:title":["Breathing Entrainment and Mechanical Ventilation in Rats"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - System and Control Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:50Z"}