{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1309506374"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1309506374","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Motion control of neuromuscular skeletal systems using a multiple contact nerve cuff electrode","abstract":"A flat interface nerve electrode (FINE) is a type of nerve cuff electrode designed to increase spatial selectivity by reshaping a nerve and realigning fascicles inside the nerve trunk. FINE has shown improved fascicular and subfascicular selectivity enabling the activation of many muscles with a single electrode. Despite significant improvement in the spatial selectivity of FINE, a motion control algorithm for Functional Electrical Stimulation (FES) using a FINE has not yet been developed, due to the inherent complexities in neuromuscular skeletal systems and the nerve-electrode interface. In this study, a novel motion control algorithm is presented to overcome these difficulties. The proposed control method does not require an analytical model of the system being controlled. Therefore, this control method is suitable for FES control with a FINE, because finding an accurate model with FINE is extremely difficult. In order to test the performance of the control algorithm, a computational model of the human ankle joint system was developed along with a finite element model of the sciatic nerve. The results indicate that both the ankle and subtalar joint motion could be controlled using a twenty-contact FINE on the sciatic nerve. The proposed controller was also tested in an acute rabbit experimental study, and the result showed good reference trajectory tracking performance within 10% average RMS error. The results in both computational simulation study and animal experiment study show that this novel control method is suitable for the system where a model is not available and where the feedback signals are difficult to obtain.","abstract_html":"A flat interface nerve electrode (FINE) is a type of nerve cuff electrode designed to increase spatial selectivity by reshaping a nerve and realigning fascicles inside the nerve trunk. FINE has shown improved fascicular and subfascicular selectivity enabling the activation of many muscles with a single electrode. Despite significant improvement in the spatial selectivity of FINE, a motion control algorithm for Functional Electrical Stimulation (FES) using a FINE has not yet been developed, due to the inherent complexities in neuromuscular skeletal systems and the nerve-electrode interface. In this study, a novel motion control algorithm is presented to overcome these difficulties. The proposed control method does not require an analytical model of the system being controlled. Therefore, this control method is suitable for FES control with a FINE, because finding an accurate model with FINE is extremely difficult. In order to test the performance of the control algorithm, a computational model of the human ankle joint system was developed along with a finite element model of the sciatic nerve. The results indicate that both the ankle and subtalar joint motion could be controlled using a twenty-contact FINE on the sciatic nerve. The proposed controller was also tested in an acute rabbit experimental study, and the result showed good reference trajectory tracking performance within 10% average RMS error. The results in both computational simulation study and animal experiment study show that this novel control method is suitable for the system where a model is not available and where the feedback signals are difficult to obtain.","abstract_has_math":false,"creators":["Park, Hyun-Joo"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Durand, Dominique"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-07-06","date_published":"2011-07-06","updated_at":"2026-11-26T03:18:47Z","subjects":["Biomedical Engineering","motion control","functional electrical stimulation","nerve electrode","flat interface nerve electrode","ankle joint","sciatic nerve","neuromuscular skeletal system"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1309506374","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1309506374","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1309506374","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1309506374","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Durand, Dominique"]},{"key":"dc:creator","label":"Author","values":["Park, Hyun-Joo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-07-06"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","motion control","functional electrical stimulation","nerve electrode","flat interface nerve electrode","ankle joint","sciatic nerve","neuromuscular skeletal system"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1309506374"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A flat interface nerve electrode (FINE) is a type of nerve cuff electrode designed to increase spatial selectivity by reshaping a nerve and realigning fascicles inside the nerve trunk. FINE has shown improved fascicular and subfascicular selectivity enabling the activation of many muscles with a single electrode. Despite significant improvement in the spatial selectivity of FINE, a motion control algorithm for Functional Electrical Stimulation (FES) using a FINE has not yet been developed, due to the inherent complexities in neuromuscular skeletal systems and the nerve-electrode interface. In this study, a novel motion control algorithm is presented to overcome these difficulties. The proposed control method does not require an analytical model of the system being controlled. Therefore, this control method is suitable for FES control with a FINE, because finding an accurate model with FINE is extremely difficult. In order to test the performance of the control algorithm, a computational model of the human ankle joint system was developed along with a finite element model of the sciatic nerve. The results indicate that both the ankle and subtalar joint motion could be controlled using a twenty-contact FINE on the sciatic nerve. The proposed controller was also tested in an acute rabbit experimental study, and the result showed good reference trajectory tracking performance within 10% average RMS error. The results in both computational simulation study and animal experiment study show that this novel control method is suitable for the system where a model is not available and where the feedback signals are difficult to obtain."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.160","1.79 MB"]},{"key":"dc:title","label":"Title","values":["Motion control of neuromuscular skeletal systems using a multiple contact nerve cuff electrode"]}]}],"canonical_facts":{"dc:contributor":["Durand, Dominique"],"dc:creator":["Park, Hyun-Joo"],"dc:date":["2011-07-06"],"dc:description":["A flat interface nerve electrode (FINE) is a type of nerve cuff electrode designed to increase spatial selectivity by reshaping a nerve and realigning fascicles inside the nerve trunk. FINE has shown improved fascicular and subfascicular selectivity enabling the activation of many muscles with a single electrode. Despite significant improvement in the spatial selectivity of FINE, a motion control algorithm for Functional Electrical Stimulation (FES) using a FINE has not yet been developed, due to the inherent complexities in neuromuscular skeletal systems and the nerve-electrode interface. In this study, a novel motion control algorithm is presented to overcome these difficulties. The proposed control method does not require an analytical model of the system being controlled. Therefore, this control method is suitable for FES control with a FINE, because finding an accurate model with FINE is extremely difficult. In order to test the performance of the control algorithm, a computational model of the human ankle joint system was developed along with a finite element model of the sciatic nerve. The results indicate that both the ankle and subtalar joint motion could be controlled using a twenty-contact FINE on the sciatic nerve. The proposed controller was also tested in an acute rabbit experimental study, and the result showed good reference trajectory tracking performance within 10% average RMS error. The results in both computational simulation study and animal experiment study show that this novel control method is suitable for the system where a model is not available and where the feedback signals are difficult to obtain."],"dc:format":["application/pdf","p.160","1.79 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1309506374"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","motion control","functional electrical stimulation","nerve electrode","flat interface nerve electrode","ankle joint","sciatic nerve","neuromuscular skeletal system"],"dc:title":["Motion control of neuromuscular skeletal systems using a multiple contact nerve cuff electrode"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:18:47Z"}