{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1313767793"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1313767793","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Optimization of Fire Blanket Performance by Varying Radiative Properties","abstract":"There is an effort to develop a thin fire blanket which can be deployed to protect structures in wildland-urban interfaces from exterior fires. The surface radiative properties of fire blankets for the protection of structures from wildland fires were variables in three optimization studies. A quasi-steady heat transfer model was used. In steady-state, there were two modes of blocking heat from reaching the structure: reflection and re-radiation of heat back toward the surroundings. The first study considered only the effectiveness of the blanket. The second considered both the effectiveness and the surface temperature facing the structure. The third used time-variant incident heat conditions. In the first study, a method to predict which mode of heat blocking was most effective, based on the incident heat conditions, was developed. In the second study, the optimal fronts provided by these two modes of blocking heat were described explicitly. In the third study, it was found that the same optimal fronts existed even when the incident heat conditions were time-variant. Finally, it was found that allowing the emissivity of the surface facing the fire to change at some temperature could improve heat blocking performance.","abstract_html":"There is an effort to develop a thin fire blanket which can be deployed to protect structures in wildland-urban interfaces from exterior fires. The surface radiative properties of fire blankets for the protection of structures from wildland fires were variables in three optimization studies. A quasi-steady heat transfer model was used. In steady-state, there were two modes of blocking heat from reaching the structure: reflection and re-radiation of heat back toward the surroundings. The first study considered only the effectiveness of the blanket. The second considered both the effectiveness and the surface temperature facing the structure. The third used time-variant incident heat conditions. In the first study, a method to predict which mode of heat blocking was most effective, based on the incident heat conditions, was developed. In the second study, the optimal fronts provided by these two modes of blocking heat were described explicitly. In the third study, it was found that the same optimal fronts existed even when the incident heat conditions were time-variant. Finally, it was found that allowing the emissivity of the surface facing the fire to change at some temperature could improve heat blocking performance.","abstract_has_math":false,"creators":["Brent, Kevin M."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EMC - Aerospace Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["T'ien, James"],"committee_members":[],"year":2012,"date_issued":"2012-01-30","date_published":"2012-01-30","updated_at":"2026-11-27T04:14:50Z","subjects":["Mechanical Engineering","fire blanket","protection","wildfire","wildland fire","thin fire blanket","steady state heat transfer"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1313767793","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1313767793","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1313767793","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1313767793","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["T'ien, James"]},{"key":"dc:creator","label":"Author","values":["Brent, Kevin M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012-01-30"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Aerospace Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","fire blanket","protection","wildfire","wildland fire","thin fire blanket","steady state heat transfer"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1313767793"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["There is an effort to develop a thin fire blanket which can be deployed to protect structures in wildland-urban interfaces from exterior fires. The surface radiative properties of fire blankets for the protection of structures from wildland fires were variables in three optimization studies. A quasi-steady heat transfer model was used. In steady-state, there were two modes of blocking heat from reaching the structure: reflection and re-radiation of heat back toward the surroundings. The first study considered only the effectiveness of the blanket. The second considered both the effectiveness and the surface temperature facing the structure. The third used time-variant incident heat conditions. In the first study, a method to predict which mode of heat blocking was most effective, based on the incident heat conditions, was developed. In the second study, the optimal fronts provided by these two modes of blocking heat were described explicitly. In the third study, it was found that the same optimal fronts existed even when the incident heat conditions were time-variant. Finally, it was found that allowing the emissivity of the surface facing the fire to change at some temperature could improve heat blocking performance."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.136","1.02 MB"]},{"key":"dc:title","label":"Title","values":["Optimization of Fire Blanket Performance by Varying Radiative Properties"]}]}],"canonical_facts":{"dc:contributor.committeechair":["T'ien, James"],"dc:creator":["Brent, Kevin M."],"dc:date":["2012-01-30"],"dc:description":["There is an effort to develop a thin fire blanket which can be deployed to protect structures in wildland-urban interfaces from exterior fires. The surface radiative properties of fire blankets for the protection of structures from wildland fires were variables in three optimization studies. A quasi-steady heat transfer model was used. In steady-state, there were two modes of blocking heat from reaching the structure: reflection and re-radiation of heat back toward the surroundings. The first study considered only the effectiveness of the blanket. The second considered both the effectiveness and the surface temperature facing the structure. The third used time-variant incident heat conditions. In the first study, a method to predict which mode of heat blocking was most effective, based on the incident heat conditions, was developed. In the second study, the optimal fronts provided by these two modes of blocking heat were described explicitly. In the third study, it was found that the same optimal fronts existed even when the incident heat conditions were time-variant. Finally, it was found that allowing the emissivity of the surface facing the fire to change at some temperature could improve heat blocking performance."],"dc:format":["application/pdf","p.136","1.02 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1313767793"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","fire blanket","protection","wildfire","wildland fire","thin fire blanket","steady state heat transfer"],"dc:title":["Optimization of Fire Blanket Performance by Varying Radiative Properties"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Aerospace Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:50Z"}