{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1315924472"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1315924472","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"INVESTIGATION OF BELOW INJURY MUSCLE SIGNALS AS A COMMAND SOURCE FOR A MOTOR NEUROPROSTHESIS","abstract":"<p>The objective of this project is to investigate muscle signals from below the injury level in individuals with motor complete spinal cord injury. Implanted neuroprostheses use functional electrical stimulation to restore function to individuals with spinal cord injury. A command signal is required to control each restored function. Currently, muscle signals from above the injury are used as a command source. As neuroprostheses advance in complexity, more command signals will be required to control the additional functions. Thus, this project was designed to evaluate potential sources of additional command information. </p><p>Although visual movement is not present in muscles below the injury level in the motor complete SCI population, it is possible to detect volitional electromyographic (EMG) activity in some muscles. Results discussed here indicate that training with visualfeedback may improve the amplitude and reliability of small muscle signals. Additionally, a proof of concept demonstration showed that clinically paralyzed muscles are a viable option for use as a command signal for an implanted, upper extremity neuroprosthesis.</p>","abstract_html":"&lt;p&gt;The objective of this project is to investigate muscle signals from below the injury level in individuals with motor complete spinal cord injury. Implanted neuroprostheses use functional electrical stimulation to restore function to individuals with spinal cord injury. A command signal is required to control each restored function. Currently, muscle signals from above the injury are used as a command source. As neuroprostheses advance in complexity, more command signals will be required to control the additional functions. Thus, this project was designed to evaluate potential sources of additional command information. &lt;/p&gt;&lt;p&gt;Although visual movement is not present in muscles below the injury level in the motor complete SCI population, it is possible to detect volitional electromyographic (EMG) activity in some muscles. Results discussed here indicate that training with visualfeedback may improve the amplitude and reliability of small muscle signals. Additionally, a proof of concept demonstration showed that clinically paralyzed muscles are a viable option for use as a command signal for an implanted, upper extremity neuroprosthesis.&lt;/p&gt;","abstract_has_math":false,"creators":["Moss, Christa Wheeler"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Peckham, P. Hunter"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-01-31","date_published":"2012-01-31","updated_at":"2026-11-27T04:14:50Z","subjects":["Biomedical Engineering","neuroprosthesis","command signal","EMG","spinal cord injury"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1315924472","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1315924472","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1315924472","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1315924472","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Peckham, P. Hunter"]},{"key":"dc:creator","label":"Author","values":["Moss, Christa Wheeler"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012-01-31"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","neuroprosthesis","command signal","EMG","spinal cord injury"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1315924472"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>The objective of this project is to investigate muscle signals from below the injury level in individuals with motor complete spinal cord injury. Implanted neuroprostheses use functional electrical stimulation to restore function to individuals with spinal cord injury. A command signal is required to control each restored function. Currently, muscle signals from above the injury are used as a command source. As neuroprostheses advance in complexity, more command signals will be required to control the additional functions. Thus, this project was designed to evaluate potential sources of additional command information. </p><p>Although visual movement is not present in muscles below the injury level in the motor complete SCI population, it is possible to detect volitional electromyographic (EMG) activity in some muscles. Results discussed here indicate that training with visualfeedback may improve the amplitude and reliability of small muscle signals. Additionally, a proof of concept demonstration showed that clinically paralyzed muscles are a viable option for use as a command signal for an implanted, upper extremity neuroprosthesis.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.103","1.34 MB"]},{"key":"dc:title","label":"Title","values":["INVESTIGATION OF BELOW INJURY MUSCLE SIGNALS AS A COMMAND SOURCE FOR A MOTOR NEUROPROSTHESIS"]}]}],"canonical_facts":{"dc:contributor.advisor":["Peckham, P. Hunter"],"dc:creator":["Moss, Christa Wheeler"],"dc:date":["2012-01-31"],"dc:description":["<p>The objective of this project is to investigate muscle signals from below the injury level in individuals with motor complete spinal cord injury. Implanted neuroprostheses use functional electrical stimulation to restore function to individuals with spinal cord injury. A command signal is required to control each restored function. Currently, muscle signals from above the injury are used as a command source. As neuroprostheses advance in complexity, more command signals will be required to control the additional functions. Thus, this project was designed to evaluate potential sources of additional command information. </p><p>Although visual movement is not present in muscles below the injury level in the motor complete SCI population, it is possible to detect volitional electromyographic (EMG) activity in some muscles. Results discussed here indicate that training with visualfeedback may improve the amplitude and reliability of small muscle signals. Additionally, a proof of concept demonstration showed that clinically paralyzed muscles are a viable option for use as a command signal for an implanted, upper extremity neuroprosthesis.</p>"],"dc:format":["application/pdf","p.103","1.34 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1315924472"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","neuroprosthesis","command signal","EMG","spinal cord injury"],"dc:title":["INVESTIGATION OF BELOW INJURY MUSCLE SIGNALS AS A COMMAND SOURCE FOR A MOTOR NEUROPROSTHESIS"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:50Z"}