{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1323374547"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1323374547","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Hybrid Position/Natural Admittance Control for Laparoscopic Surgery","abstract":"Minimally-invasive surgery, notably with the use of robots, is a rapidly growing area due to the potential benefits of faster recovery times and lower risk of infection relative to conventional surgery. However, current practice is slow and cumbersome, motivating research in more competent and more efficient robotic surgery. Current research includes robotic assistants that could perform long, repetitive tasks such as suturing. For these assistants, two controllers were developed that obey the portal constraint while maintaining a compliant tip. The first controller was a variation of Natural Admittance Control. The second merged Natural Admittance Control and hybrid force/position control. The results showed that the hybrid controller is 3.5 times better at conforming to the portal kinematic constraint than the Natural Admittance Control algorithm.","abstract_html":"Minimally-invasive surgery, notably with the use of robots, is a rapidly growing area due to the potential benefits of faster recovery times and lower risk of infection relative to conventional surgery. However, current practice is slow and cumbersome, motivating research in more competent and more efficient robotic surgery. Current research includes robotic assistants that could perform long, repetitive tasks such as suturing. For these assistants, two controllers were developed that obey the portal constraint while maintaining a compliant tip. The first controller was a variation of Natural Admittance Control. The second merged Natural Admittance Control and hybrid force/position control. The results showed that the hybrid controller is 3.5 times better at conforming to the portal kinematic constraint than the Natural Admittance Control algorithm.","abstract_has_math":false,"creators":["Deal, Aaron M."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EECS - Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Newman, Wyatt"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-01-30","date_published":"2012-01-30","updated_at":"2026-11-27T04:14:50Z","subjects":["Robotics"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1323374547","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1323374547","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1323374547","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1323374547","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Newman, Wyatt"]},{"key":"dc:creator","label":"Author","values":["Deal, Aaron M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012-01-30"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Robotics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1323374547"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Minimally-invasive surgery, notably with the use of robots, is a rapidly growing area due to the potential benefits of faster recovery times and lower risk of infection relative to conventional surgery. However, current practice is slow and cumbersome, motivating research in more competent and more efficient robotic surgery. Current research includes robotic assistants that could perform long, repetitive tasks such as suturing. For these assistants, two controllers were developed that obey the portal constraint while maintaining a compliant tip. The first controller was a variation of Natural Admittance Control. The second merged Natural Admittance Control and hybrid force/position control. The results showed that the hybrid controller is 3.5 times better at conforming to the portal kinematic constraint than the Natural Admittance Control algorithm."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.87","2.85 MB"]},{"key":"dc:title","label":"Title","values":["Hybrid Position/Natural Admittance Control for Laparoscopic Surgery"]}]}],"canonical_facts":{"dc:contributor.advisor":["Newman, Wyatt"],"dc:creator":["Deal, Aaron M."],"dc:date":["2012-01-30"],"dc:description":["Minimally-invasive surgery, notably with the use of robots, is a rapidly growing area due to the potential benefits of faster recovery times and lower risk of infection relative to conventional surgery. However, current practice is slow and cumbersome, motivating research in more competent and more efficient robotic surgery. Current research includes robotic assistants that could perform long, repetitive tasks such as suturing. For these assistants, two controllers were developed that obey the portal constraint while maintaining a compliant tip. The first controller was a variation of Natural Admittance Control. The second merged Natural Admittance Control and hybrid force/position control. The results showed that the hybrid controller is 3.5 times better at conforming to the portal kinematic constraint than the Natural Admittance Control algorithm."],"dc:format":["application/pdf","p.87","2.85 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1323374547"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Robotics"],"dc:title":["Hybrid Position/Natural Admittance Control for Laparoscopic Surgery"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:50Z"}