{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1323445335"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1323445335","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Roller-Cast Poly-Dimethylsiloxane as a Non-Hermetic Encapsulant for MEMS Packaging","abstract":"This thesis describes the development of a roller-casting process for multi-layered poly-dimethylsiloxane films to be used as an encapsulant for implantable MEMS. Accelerated lifetime studies were conducted at 40°C and 85°C in saline solution on sixteen samples each containing eight interdigitated electrode arrays and encapsulated with Dow Corning MDX4-4210 Biomedical Grade Elastomer. A custom environmental testing system designed for long-term, unmonitored testing was built to acquire resistance measurements. Select samples received surface treatments prior to PDMS deposition to enhance adhesion and were evaluated by pull-off tests before and after soak testing. Test results show lifetimes up to 40 days for samples tested at 85°C. Samples in 40°C saline solution are still under test with no device failures after 68 days. The estimated maximum lifetime of packages made using the roller casting method based on previously published data is 5.5 years at physiological temperature (37°C) and 22.2 years at 25°C.","abstract_html":"This thesis describes the development of a roller-casting process for multi-layered poly-dimethylsiloxane films to be used as an encapsulant for implantable MEMS. Accelerated lifetime studies were conducted at 40°C and 85°C in saline solution on sixteen samples each containing eight interdigitated electrode arrays and encapsulated with Dow Corning MDX4-4210 Biomedical Grade Elastomer. A custom environmental testing system designed for long-term, unmonitored testing was built to acquire resistance measurements. Select samples received surface treatments prior to PDMS deposition to enhance adhesion and were evaluated by pull-off tests before and after soak testing. Test results show lifetimes up to 40 days for samples tested at 85°C. Samples in 40°C saline solution are still under test with no device failures after 68 days. The estimated maximum lifetime of packages made using the roller casting method based on previously published data is 5.5 years at physiological temperature (37°C) and 22.2 years at 25°C.","abstract_has_math":false,"creators":["Lachhman, Shem Benjamin"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EECS - Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Zorman, Christian"],"committee_chairs":["Ko, Wen"],"committee_members":[],"year":2012,"date_issued":"2012-01-30","date_published":"2012-01-30","updated_at":"2026-11-27T04:14:50Z","subjects":["Electrical Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1323445335","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1323445335","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1323445335","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1323445335","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zorman, Christian"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Ko, Wen"]},{"key":"dc:creator","label":"Author","values":["Lachhman, Shem Benjamin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012-01-30"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1323445335"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This thesis describes the development of a roller-casting process for multi-layered poly-dimethylsiloxane films to be used as an encapsulant for implantable MEMS. Accelerated lifetime studies were conducted at 40°C and 85°C in saline solution on sixteen samples each containing eight interdigitated electrode arrays and encapsulated with Dow Corning MDX4-4210 Biomedical Grade Elastomer. A custom environmental testing system designed for long-term, unmonitored testing was built to acquire resistance measurements. Select samples received surface treatments prior to PDMS deposition to enhance adhesion and were evaluated by pull-off tests before and after soak testing. Test results show lifetimes up to 40 days for samples tested at 85°C. Samples in 40°C saline solution are still under test with no device failures after 68 days. The estimated maximum lifetime of packages made using the roller casting method based on previously published data is 5.5 years at physiological temperature (37°C) and 22.2 years at 25°C."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.106","2.67 MB"]},{"key":"dc:title","label":"Title","values":["Roller-Cast Poly-Dimethylsiloxane as a Non-Hermetic Encapsulant for MEMS Packaging"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zorman, Christian"],"dc:contributor.committeechair":["Ko, Wen"],"dc:creator":["Lachhman, Shem Benjamin"],"dc:date":["2012-01-30"],"dc:description":["This thesis describes the development of a roller-casting process for multi-layered poly-dimethylsiloxane films to be used as an encapsulant for implantable MEMS. Accelerated lifetime studies were conducted at 40°C and 85°C in saline solution on sixteen samples each containing eight interdigitated electrode arrays and encapsulated with Dow Corning MDX4-4210 Biomedical Grade Elastomer. A custom environmental testing system designed for long-term, unmonitored testing was built to acquire resistance measurements. Select samples received surface treatments prior to PDMS deposition to enhance adhesion and were evaluated by pull-off tests before and after soak testing. Test results show lifetimes up to 40 days for samples tested at 85°C. Samples in 40°C saline solution are still under test with no device failures after 68 days. The estimated maximum lifetime of packages made using the roller casting method based on previously published data is 5.5 years at physiological temperature (37°C) and 22.2 years at 25°C."],"dc:format":["application/pdf","p.106","2.67 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1323445335"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Electrical Engineering"],"dc:title":["Roller-Cast Poly-Dimethylsiloxane as a Non-Hermetic Encapsulant for MEMS Packaging"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:14:50Z"}