{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1332258338"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1332258338","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Application of Ultrasound Imaging for Noninvasive Characterization of Phase Inverting Implants","abstract":"<p>Cancer is a global disease that affects millions of people annually. Primary treatment relies on the surgical resection of the lesion followed by adjuvant chemotherapy regimens. As a result of the systemic delivery of these drugs, healthy tissue is also targeted, resulting in dose limiting toxicity. One method for targeting the delivery of drugs to the tumor and limiting the action of these agents on healthy tissues is through the placement of drug eluting depots within the tumor, which can reduce systemic exposure of the delivered agent while elevating the local concentrations. In situ forming implants provide an ideal means by which these depots can be physically targeted to the tissue. These injectable implants are liquid solutions outside of the body, but solidify into solid implants upon contact with an aqueous environment through a process known as phase inversion. </p><p>Currently, use of in situ forming implants is limited due to a poor understanding of how the environment of the injection site affects overall implant behavior. This thesis outlines the development of a novel noninvasive technique for characterizing the behavior of these implants in situ with ultrasound imaging. A correlation was developed that can be used to approximate the burst release of drug from these implants as a function of the phase inversion data obtained through image analysis. Additionally, implant formulation parameters were modified so that the effect of cargo properties on implant behavior could be evaluated. Tunable swelling, phase inversion, degradation, erosion, and release were obtained by altering the Mw of the polymer used in the initial implant formulation. Finally the effect of the injection site on implant behavior was evaluated using diagnostic ultrasound. These studies identified that the stiffness of the injection site has a direct effect on the drug release profile, and the polymers that undergo a greater degree of swelling ultimately release more drug in vivo. The techniques developed in this thesis may be used to further elucidate the underlying parameters that control phase inversion and drug release in vivo, and may lead to the development of optimal implant formulations that can provide improved treatment efficacy.</p>","abstract_html":"&lt;p&gt;Cancer is a global disease that affects millions of people annually. Primary treatment relies on the surgical resection of the lesion followed by adjuvant chemotherapy regimens. As a result of the systemic delivery of these drugs, healthy tissue is also targeted, resulting in dose limiting toxicity. One method for targeting the delivery of drugs to the tumor and limiting the action of these agents on healthy tissues is through the placement of drug eluting depots within the tumor, which can reduce systemic exposure of the delivered agent while elevating the local concentrations. In situ forming implants provide an ideal means by which these depots can be physically targeted to the tissue. These injectable implants are liquid solutions outside of the body, but solidify into solid implants upon contact with an aqueous environment through a process known as phase inversion. &lt;/p&gt;&lt;p&gt;Currently, use of in situ forming implants is limited due to a poor understanding of how the environment of the injection site affects overall implant behavior. This thesis outlines the development of a novel noninvasive technique for characterizing the behavior of these implants in situ with ultrasound imaging. A correlation was developed that can be used to approximate the burst release of drug from these implants as a function of the phase inversion data obtained through image analysis. Additionally, implant formulation parameters were modified so that the effect of cargo properties on implant behavior could be evaluated. Tunable swelling, phase inversion, degradation, erosion, and release were obtained by altering the Mw of the polymer used in the initial implant formulation. Finally the effect of the injection site on implant behavior was evaluated using diagnostic ultrasound. These studies identified that the stiffness of the injection site has a direct effect on the drug release profile, and the polymers that undergo a greater degree of swelling ultimately release more drug in vivo. The techniques developed in this thesis may be used to further elucidate the underlying parameters that control phase inversion and drug release in vivo, and may lead to the development of optimal implant formulations that can provide improved treatment efficacy.&lt;/p&gt;","abstract_has_math":false,"creators":["Solorio, Luis, Jr."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Exner, Agata","Wilson, David"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-06-26","date_published":"2012-06-26","updated_at":"2026-11-26T03:19:02Z","subjects":["Biomedical Engineering","phase inversion","in situ forming implant","ultrasound imaging","noninvasive characterization","drug delivery"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1332258338","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1332258338","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1332258338","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1332258338","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Exner, Agata","Wilson, David"]},{"key":"dc:creator","label":"Author","values":["Solorio, Luis, Jr."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012-06-26"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","phase inversion","in situ forming implant","ultrasound imaging","noninvasive characterization","drug delivery"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1332258338"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Cancer is a global disease that affects millions of people annually. Primary treatment relies on the surgical resection of the lesion followed by adjuvant chemotherapy regimens. As a result of the systemic delivery of these drugs, healthy tissue is also targeted, resulting in dose limiting toxicity. One method for targeting the delivery of drugs to the tumor and limiting the action of these agents on healthy tissues is through the placement of drug eluting depots within the tumor, which can reduce systemic exposure of the delivered agent while elevating the local concentrations. In situ forming implants provide an ideal means by which these depots can be physically targeted to the tissue. These injectable implants are liquid solutions outside of the body, but solidify into solid implants upon contact with an aqueous environment through a process known as phase inversion. </p><p>Currently, use of in situ forming implants is limited due to a poor understanding of how the environment of the injection site affects overall implant behavior. This thesis outlines the development of a novel noninvasive technique for characterizing the behavior of these implants in situ with ultrasound imaging. A correlation was developed that can be used to approximate the burst release of drug from these implants as a function of the phase inversion data obtained through image analysis. Additionally, implant formulation parameters were modified so that the effect of cargo properties on implant behavior could be evaluated. Tunable swelling, phase inversion, degradation, erosion, and release were obtained by altering the Mw of the polymer used in the initial implant formulation. Finally the effect of the injection site on implant behavior was evaluated using diagnostic ultrasound. These studies identified that the stiffness of the injection site has a direct effect on the drug release profile, and the polymers that undergo a greater degree of swelling ultimately release more drug in vivo. The techniques developed in this thesis may be used to further elucidate the underlying parameters that control phase inversion and drug release in vivo, and may lead to the development of optimal implant formulations that can provide improved treatment efficacy.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.261","3.82 MB"]},{"key":"dc:title","label":"Title","values":["Application of Ultrasound Imaging for Noninvasive Characterization of Phase Inverting Implants"]}]}],"canonical_facts":{"dc:contributor":["Exner, Agata","Wilson, David"],"dc:creator":["Solorio, Luis, Jr."],"dc:date":["2012-06-26"],"dc:description":["<p>Cancer is a global disease that affects millions of people annually. Primary treatment relies on the surgical resection of the lesion followed by adjuvant chemotherapy regimens. As a result of the systemic delivery of these drugs, healthy tissue is also targeted, resulting in dose limiting toxicity. One method for targeting the delivery of drugs to the tumor and limiting the action of these agents on healthy tissues is through the placement of drug eluting depots within the tumor, which can reduce systemic exposure of the delivered agent while elevating the local concentrations. In situ forming implants provide an ideal means by which these depots can be physically targeted to the tissue. These injectable implants are liquid solutions outside of the body, but solidify into solid implants upon contact with an aqueous environment through a process known as phase inversion. </p><p>Currently, use of in situ forming implants is limited due to a poor understanding of how the environment of the injection site affects overall implant behavior. This thesis outlines the development of a novel noninvasive technique for characterizing the behavior of these implants in situ with ultrasound imaging. A correlation was developed that can be used to approximate the burst release of drug from these implants as a function of the phase inversion data obtained through image analysis. Additionally, implant formulation parameters were modified so that the effect of cargo properties on implant behavior could be evaluated. Tunable swelling, phase inversion, degradation, erosion, and release were obtained by altering the Mw of the polymer used in the initial implant formulation. Finally the effect of the injection site on implant behavior was evaluated using diagnostic ultrasound. These studies identified that the stiffness of the injection site has a direct effect on the drug release profile, and the polymers that undergo a greater degree of swelling ultimately release more drug in vivo. The techniques developed in this thesis may be used to further elucidate the underlying parameters that control phase inversion and drug release in vivo, and may lead to the development of optimal implant formulations that can provide improved treatment efficacy.</p>"],"dc:format":["application/pdf","p.261","3.82 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1332258338"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","phase inversion","in situ forming implant","ultrasound imaging","noninvasive characterization","drug delivery"],"dc:title":["Application of Ultrasound Imaging for Noninvasive Characterization of Phase Inverting Implants"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:19:02Z"}