{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1333675768"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1333675768","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Measurements of Air Flow Velocities in Microchannels Using Particle Image Velocimetry","abstract":"The knowledge of the flow field in microchannels is becoming increasingly important with the advent of the ionic wind pump and other microscale heat removal devices. The understanding of this flow field will lead to more effective and improved designs. Non-intrusive microscale particle image velocimetry (PIV) utilizing a microscopic objective lens is used to obtain the velocity field in microchannels. The scales of these channels are similar to those encountered in such devices as the ionic wind pump. Microchannels with dimensions ranging from 0.8 mm to 2 mm are used. Computational fluid dynamics (CFD) models are used to replicate each test, with varying inlet conditions and mesh densities. The CFD flow fields are compared to the PIV results for validation purposes, with relative errors between CFD and PIV typically between 2% and 10%. The agreement between the experimental data and computational results ranged from acceptable to excellent, validating this method. The channel with lowest aspect ratio consistently showed the largest agreement between experimental and numerical values.","abstract_html":"The knowledge of the flow field in microchannels is becoming increasingly important with the advent of the ionic wind pump and other microscale heat removal devices. The understanding of this flow field will lead to more effective and improved designs. Non-intrusive microscale particle image velocimetry (PIV) utilizing a microscopic objective lens is used to obtain the velocity field in microchannels. The scales of these channels are similar to those encountered in such devices as the ionic wind pump. Microchannels with dimensions ranging from 0.8 mm to 2 mm are used. Computational fluid dynamics (CFD) models are used to replicate each test, with varying inlet conditions and mesh densities. The CFD flow fields are compared to the PIV results for validation purposes, with relative errors between CFD and PIV typically between 2% and 10%. The agreement between the experimental data and computational results ranged from acceptable to excellent, validating this method. The channel with lowest aspect ratio consistently showed the largest agreement between experimental and numerical values.","abstract_has_math":false,"creators":["Doucet, Daniel Joseph"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EMC - Aerospace Engineering","degree_department":null,"school":null,"contributors":["Kadambi, Jaikrishnan R."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-05-22","date_published":"2012-05-22","updated_at":"2026-11-26T03:19:02Z","subjects":["Aerospace Engineering","Fluid Dynamics","Mechanical Engineering","particle image velocimetry","computational fluid dynamics","microchannel","experimental fluid mechanics"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1333675768","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1333675768","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1333675768","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1333675768","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kadambi, Jaikrishnan R."]},{"key":"dc:creator","label":"Author","values":["Doucet, Daniel Joseph"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012-05-22"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Aerospace Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Aerospace Engineering","Fluid Dynamics","Mechanical Engineering","particle image velocimetry","computational fluid dynamics","microchannel","experimental fluid mechanics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1333675768"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The knowledge of the flow field in microchannels is becoming increasingly important with the advent of the ionic wind pump and other microscale heat removal devices. The understanding of this flow field will lead to more effective and improved designs. Non-intrusive microscale particle image velocimetry (PIV) utilizing a microscopic objective lens is used to obtain the velocity field in microchannels. The scales of these channels are similar to those encountered in such devices as the ionic wind pump. Microchannels with dimensions ranging from 0.8 mm to 2 mm are used. Computational fluid dynamics (CFD) models are used to replicate each test, with varying inlet conditions and mesh densities. The CFD flow fields are compared to the PIV results for validation purposes, with relative errors between CFD and PIV typically between 2% and 10%. The agreement between the experimental data and computational results ranged from acceptable to excellent, validating this method. The channel with lowest aspect ratio consistently showed the largest agreement between experimental and numerical values."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.69","2.95 MB"]},{"key":"dc:title","label":"Title","values":["Measurements of Air Flow Velocities in Microchannels Using Particle Image Velocimetry"]}]}],"canonical_facts":{"dc:contributor":["Kadambi, Jaikrishnan R."],"dc:creator":["Doucet, Daniel Joseph"],"dc:date":["2012-05-22"],"dc:description":["The knowledge of the flow field in microchannels is becoming increasingly important with the advent of the ionic wind pump and other microscale heat removal devices. The understanding of this flow field will lead to more effective and improved designs. Non-intrusive microscale particle image velocimetry (PIV) utilizing a microscopic objective lens is used to obtain the velocity field in microchannels. The scales of these channels are similar to those encountered in such devices as the ionic wind pump. Microchannels with dimensions ranging from 0.8 mm to 2 mm are used. Computational fluid dynamics (CFD) models are used to replicate each test, with varying inlet conditions and mesh densities. The CFD flow fields are compared to the PIV results for validation purposes, with relative errors between CFD and PIV typically between 2% and 10%. The agreement between the experimental data and computational results ranged from acceptable to excellent, validating this method. The channel with lowest aspect ratio consistently showed the largest agreement between experimental and numerical values."],"dc:format":["application/pdf","p.69","2.95 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1333675768"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Aerospace Engineering","Fluid Dynamics","Mechanical Engineering","particle image velocimetry","computational fluid dynamics","microchannel","experimental fluid mechanics"],"dc:title":["Measurements of Air Flow Velocities in Microchannels Using Particle Image Velocimetry"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Aerospace Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:19:02Z"}