{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1339170465"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1339170465","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"The Frequency, Aqueous Solution, Stress Amplitude,Temperature (FAST) Machine: A Device Proposed for Accelerated Fatigue Testing of Cortical Bone","abstract":"Fatigue testing is a well – established method for determining the mechanical properties of materials subjected to repeated loading. Stress fractures in cortical bone are a clinically recognized public health concern, believed to result from cyclic loading. There is currently no cost – effective device that accounts for the variety of factors influencing the fatigue behavior of bone in vivo. The FAST Machine, a constant stress amplitude rotating bending fatigue test designed in accordance with the design process, is proposed as a possible solution. Bovine cortical bone specimens designed and machined with reference to ASTM standards were fatigued. The results were determined to be in accordance with the expected fatigue and fracture patterns reported in current literature. The FAST Machine was also found to be affordable at a component cost of $2,150 and applicable to the testing of materials in research areas other than the study of cortical bone.","abstract_html":"Fatigue testing is a well – established method for determining the mechanical properties of materials subjected to repeated loading. Stress fractures in cortical bone are a clinically recognized public health concern, believed to result from cyclic loading. There is currently no cost – effective device that accounts for the variety of factors influencing the fatigue behavior of bone in vivo. The FAST Machine, a constant stress amplitude rotating bending fatigue test designed in accordance with the design process, is proposed as a possible solution. Bovine cortical bone specimens designed and machined with reference to ASTM standards were fatigued. The results were determined to be in accordance with the expected fatigue and fracture patterns reported in current literature. The FAST Machine was also found to be affordable at a component cost of $2,150 and applicable to the testing of materials in research areas other than the study of cortical bone.","abstract_has_math":false,"creators":["Moore, Emily"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Akkus, Ozan","Eppell, Steven","Rimnac, Clare"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-08-27","date_published":"2012-08-27","updated_at":"2026-11-26T03:19:02Z","subjects":["Biomedical Engineering","Biomedical Research","Materials Science","Mechanical Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1339170465","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1339170465","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1339170465","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1339170465","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Akkus, Ozan","Eppell, Steven","Rimnac, Clare"]},{"key":"dc:creator","label":"Author","values":["Moore, Emily"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012-08-27"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Biomedical Research","Materials Science","Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1339170465"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Fatigue testing is a well – established method for determining the mechanical properties of materials subjected to repeated loading. Stress fractures in cortical bone are a clinically recognized public health concern, believed to result from cyclic loading. There is currently no cost – effective device that accounts for the variety of factors influencing the fatigue behavior of bone in vivo. The FAST Machine, a constant stress amplitude rotating bending fatigue test designed in accordance with the design process, is proposed as a possible solution. Bovine cortical bone specimens designed and machined with reference to ASTM standards were fatigued. The results were determined to be in accordance with the expected fatigue and fracture patterns reported in current literature. The FAST Machine was also found to be affordable at a component cost of $2,150 and applicable to the testing of materials in research areas other than the study of cortical bone."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.230","6.39 MB"]},{"key":"dc:title","label":"Title","values":["The Frequency, Aqueous Solution, Stress Amplitude,Temperature (FAST) Machine: A Device Proposed for Accelerated Fatigue Testing of Cortical Bone"]}]}],"canonical_facts":{"dc:contributor":["Akkus, Ozan","Eppell, Steven","Rimnac, Clare"],"dc:creator":["Moore, Emily"],"dc:date":["2012-08-27"],"dc:description":["Fatigue testing is a well – established method for determining the mechanical properties of materials subjected to repeated loading. Stress fractures in cortical bone are a clinically recognized public health concern, believed to result from cyclic loading. There is currently no cost – effective device that accounts for the variety of factors influencing the fatigue behavior of bone in vivo. The FAST Machine, a constant stress amplitude rotating bending fatigue test designed in accordance with the design process, is proposed as a possible solution. Bovine cortical bone specimens designed and machined with reference to ASTM standards were fatigued. The results were determined to be in accordance with the expected fatigue and fracture patterns reported in current literature. The FAST Machine was also found to be affordable at a component cost of $2,150 and applicable to the testing of materials in research areas other than the study of cortical bone."],"dc:format":["application/pdf","p.230","6.39 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1339170465"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Biomedical Research","Materials Science","Mechanical Engineering"],"dc:title":["The Frequency, Aqueous Solution, Stress Amplitude,Temperature (FAST) Machine: A Device Proposed for Accelerated Fatigue Testing of Cortical Bone"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:19:02Z"}