{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1370342677"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1370342677","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"DESIGN AND DEVELOPMENT OF A SEISMIC ISOLATIONSYSTEM FOR COMMERCIAL STORAGE RACKS","abstract":"During the past forty years, the number of large retail stores (often referred to as big-box stores) has grown significantly. These stores incorporate steel pallet storage racks loaded with heavy merchandise which pose a life-safety risk to the exposed general public during a seismic event. A base isolation system compatible with conventional racks is designed and developed which provides seismic isolation primarily in the cross-aisle direction. The new patented base isolation system provides seismic isolation by incorporating heavily damped elastomeric bearings (referred to here as seismic mounts) and low-friction bearing plates. The objective of the base isolation system is to reduce horizontal accelerations of the rack to eliminate product shedding and structural damage during a major earthquake without interfering with normal, day-to-day material handling operations. Full scale shake table testing show the new base isolation system meets the performance objectives recommended in the FEMA-460 document “Seismic Considerations for Steel Storage Racks Located in Areas Accessible to the Public” for both life safety under the Design Earthquake (DE) and for collapse prevention under the Maximum Considered Earthquake (MCE).Special heavily damped (HD) butyl compounds are developed and utilized in the seismic mounts. These compounds are statically and dynamically characterized which provides input data for numerical studies. Non-linear hyperelastic material models are developed and used with finite element analysis to design various base isolation systems. Several of these new base isolation systems are optimized to achieve characteristics that expand their use from lightly loaded racks to heavily loaded racks. Designs are further optimized based on feedback from shake table testing and transient structural analysis.The new base isolation system is evaluated by uniaxial and triaxial shake table tests performed at the Structural Engineering and Earthquake Simulation Laboratory (SEESL) at the University of Buffalo (UB). Three phases of testing were performed on steel pallet storage racks both directly anchored (conventional) and with the new base isolation system. Tests were performed with both simulated and real merchandise. The results of the seismic tests demonstrate the improved structural performance of rack structures incorporating the new base isolation system. Cross-aisle absolute accelerations and inter-story drifts of the base isolated rack structure are reduced by more than 70% compared to the same rack conventionally anchored at its base. Numerical simulations (transient structural, finite element analysis) are presented comparing storage rack response against tests performed on the tri-axial shake table. The simulations agree with experimental test results within 20%. The simulation model is used to determine optimal seismic isolation parameters that satisfy the practical range of rack shelf loads and configurations expected in typical warehouse and store installations.","abstract_html":"During the past forty years, the number of large retail stores (often referred to as big-box stores) has grown significantly. These stores incorporate steel pallet storage racks loaded with heavy merchandise which pose a life-safety risk to the exposed general public during a seismic event. A base isolation system compatible with conventional racks is designed and developed which provides seismic isolation primarily in the cross-aisle direction. The new patented base isolation system provides seismic isolation by incorporating heavily damped elastomeric bearings (referred to here as seismic mounts) and low-friction bearing plates. The objective of the base isolation system is to reduce horizontal accelerations of the rack to eliminate product shedding and structural damage during a major earthquake without interfering with normal, day-to-day material handling operations. Full scale shake table testing show the new base isolation system meets the performance objectives recommended in the FEMA-460 document “Seismic Considerations for Steel Storage Racks Located in Areas Accessible to the Public” for both life safety under the Design Earthquake (DE) and for collapse prevention under the Maximum Considered Earthquake (MCE).Special heavily damped (HD) butyl compounds are developed and utilized in the seismic mounts. These compounds are statically and dynamically characterized which provides input data for numerical studies. Non-linear hyperelastic material models are developed and used with finite element analysis to design various base isolation systems. Several of these new base isolation systems are optimized to achieve characteristics that expand their use from lightly loaded racks to heavily loaded racks. Designs are further optimized based on feedback from shake table testing and transient structural analysis.The new base isolation system is evaluated by uniaxial and triaxial shake table tests performed at the Structural Engineering and Earthquake Simulation Laboratory (SEESL) at the University of Buffalo (UB). Three phases of testing were performed on steel pallet storage racks both directly anchored (conventional) and with the new base isolation system. Tests were performed with both simulated and real merchandise. The results of the seismic tests demonstrate the improved structural performance of rack structures incorporating the new base isolation system. Cross-aisle absolute accelerations and inter-story drifts of the base isolated rack structure are reduced by more than 70% compared to the same rack conventionally anchored at its base. Numerical simulations (transient structural, finite element analysis) are presented comparing storage rack response against tests performed on the tri-axial shake table. The simulations agree with experimental test results within 20%. The simulation model is used to determine optimal seismic isolation parameters that satisfy the practical range of rack shelf loads and configurations expected in typical warehouse and store installations.","abstract_has_math":false,"creators":["Michael, Robert Joseph"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Prahl, Joe"],"committee_chairs":["Huckelbridge, Arthur"],"committee_members":[],"year":2013,"date_issued":"2013-08-23","date_published":"2013-08-23","updated_at":"2026-11-27T04:12:58Z","subjects":["Mechanical Engineering","seismic isolation heavily damped elastomers butyl material characterization base isolation storage racks passive base isolation hyperelastic analysis dynamic analysis of storage racks"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1370342677","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1370342677","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1370342677","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1370342677","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Prahl, Joe"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Huckelbridge, Arthur"]},{"key":"dc:creator","label":"Author","values":["Michael, Robert Joseph"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013-08-23"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","seismic isolation heavily damped elastomers butyl material characterization base isolation storage racks passive base isolation hyperelastic analysis dynamic analysis of storage racks"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1370342677"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["During the past forty years, the number of large retail stores (often referred to as big-box stores) has grown significantly. These stores incorporate steel pallet storage racks loaded with heavy merchandise which pose a life-safety risk to the exposed general public during a seismic event. A base isolation system compatible with conventional racks is designed and developed which provides seismic isolation primarily in the cross-aisle direction. The new patented base isolation system provides seismic isolation by incorporating heavily damped elastomeric bearings (referred to here as seismic mounts) and low-friction bearing plates. The objective of the base isolation system is to reduce horizontal accelerations of the rack to eliminate product shedding and structural damage during a major earthquake without interfering with normal, day-to-day material handling operations. Full scale shake table testing show the new base isolation system meets the performance objectives recommended in the FEMA-460 document “Seismic Considerations for Steel Storage Racks Located in Areas Accessible to the Public” for both life safety under the Design Earthquake (DE) and for collapse prevention under the Maximum Considered Earthquake (MCE).Special heavily damped (HD) butyl compounds are developed and utilized in the seismic mounts. These compounds are statically and dynamically characterized which provides input data for numerical studies. Non-linear hyperelastic material models are developed and used with finite element analysis to design various base isolation systems. Several of these new base isolation systems are optimized to achieve characteristics that expand their use from lightly loaded racks to heavily loaded racks. Designs are further optimized based on feedback from shake table testing and transient structural analysis.The new base isolation system is evaluated by uniaxial and triaxial shake table tests performed at the Structural Engineering and Earthquake Simulation Laboratory (SEESL) at the University of Buffalo (UB). Three phases of testing were performed on steel pallet storage racks both directly anchored (conventional) and with the new base isolation system. Tests were performed with both simulated and real merchandise. The results of the seismic tests demonstrate the improved structural performance of rack structures incorporating the new base isolation system. Cross-aisle absolute accelerations and inter-story drifts of the base isolated rack structure are reduced by more than 70% compared to the same rack conventionally anchored at its base. Numerical simulations (transient structural, finite element analysis) are presented comparing storage rack response against tests performed on the tri-axial shake table. The simulations agree with experimental test results within 20%. The simulation model is used to determine optimal seismic isolation parameters that satisfy the practical range of rack shelf loads and configurations expected in typical warehouse and store installations."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.477","14.99 MB"]},{"key":"dc:title","label":"Title","values":["DESIGN AND DEVELOPMENT OF A SEISMIC ISOLATIONSYSTEM FOR COMMERCIAL STORAGE RACKS"]}]}],"canonical_facts":{"dc:contributor.advisor":["Prahl, Joe"],"dc:contributor.committeechair":["Huckelbridge, Arthur"],"dc:creator":["Michael, Robert Joseph"],"dc:date":["2013-08-23"],"dc:description":["During the past forty years, the number of large retail stores (often referred to as big-box stores) has grown significantly. These stores incorporate steel pallet storage racks loaded with heavy merchandise which pose a life-safety risk to the exposed general public during a seismic event. A base isolation system compatible with conventional racks is designed and developed which provides seismic isolation primarily in the cross-aisle direction. The new patented base isolation system provides seismic isolation by incorporating heavily damped elastomeric bearings (referred to here as seismic mounts) and low-friction bearing plates. The objective of the base isolation system is to reduce horizontal accelerations of the rack to eliminate product shedding and structural damage during a major earthquake without interfering with normal, day-to-day material handling operations. Full scale shake table testing show the new base isolation system meets the performance objectives recommended in the FEMA-460 document “Seismic Considerations for Steel Storage Racks Located in Areas Accessible to the Public” for both life safety under the Design Earthquake (DE) and for collapse prevention under the Maximum Considered Earthquake (MCE).Special heavily damped (HD) butyl compounds are developed and utilized in the seismic mounts. These compounds are statically and dynamically characterized which provides input data for numerical studies. Non-linear hyperelastic material models are developed and used with finite element analysis to design various base isolation systems. Several of these new base isolation systems are optimized to achieve characteristics that expand their use from lightly loaded racks to heavily loaded racks. Designs are further optimized based on feedback from shake table testing and transient structural analysis.The new base isolation system is evaluated by uniaxial and triaxial shake table tests performed at the Structural Engineering and Earthquake Simulation Laboratory (SEESL) at the University of Buffalo (UB). Three phases of testing were performed on steel pallet storage racks both directly anchored (conventional) and with the new base isolation system. Tests were performed with both simulated and real merchandise. The results of the seismic tests demonstrate the improved structural performance of rack structures incorporating the new base isolation system. Cross-aisle absolute accelerations and inter-story drifts of the base isolated rack structure are reduced by more than 70% compared to the same rack conventionally anchored at its base. Numerical simulations (transient structural, finite element analysis) are presented comparing storage rack response against tests performed on the tri-axial shake table. The simulations agree with experimental test results within 20%. The simulation model is used to determine optimal seismic isolation parameters that satisfy the practical range of rack shelf loads and configurations expected in typical warehouse and store installations."],"dc:format":["application/pdf","p.477","14.99 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1370342677"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","seismic isolation heavily damped elastomers butyl material characterization base isolation storage racks passive base isolation hyperelastic analysis dynamic analysis of storage racks"],"dc:title":["DESIGN AND DEVELOPMENT OF A SEISMIC ISOLATIONSYSTEM FOR COMMERCIAL STORAGE RACKS"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:12:58Z"}