{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1370865200"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1370865200","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Relaxation Effects in Magnetic Nanoparticle Physics: MPI and MPS Applications","abstract":"As components of dilute ferrofluids, magnetic nanoparticles have been playing an important role in medical industry because of their roles as tracer materials, biomarkers and biosensors. Magnetic particle imaging (MPI) is one of the applications based on the nonlinear response of superparamagnetic iron oxide (SPIO) nanoparticles to external magnetic fields. MPI generates maps of tracer concentration through the use of a static but spatially inhomogeneous field (selection field) and homogeneous oscillating field (drive field). Magnetic particle spectroscopy (MPS) is another interesting application of magnetic particles that measures the magnetic response and the harmonic signal spectrum of the magnetic particles. In the early stage of MPI and MPS, the equilibrium magnetization, or the Langevin magnetization, had been assumed. However, the relaxation effects of the magnetic nanoparticles have to be taken into account due to the existence of fast oscillating magnetic fields in the applications such as MPI and MPS,. In this study, two relaxation mechanisms, Neel relaxation and Brownian relaxation, are introduced into MPI through the Bloch equation. Numerical results indicate that MPI is sensitive to the relaxation time of the nanoparticles. Our simulation also leads to the conclusion that an optimal nanoparticle size can be found in MPI. However, the Bloch equation is a phenomenological equation for studies where the response of the particles is approximately linear. To understand and predict the experimental results with high drive frequency and strong drive field more accurately, two stochastic equations, the Landau-Lifshitz-Gilbert equation and the Fokker-Planck equation, are analytically and numerically studied. The Fokker-Planck equation is solved using an expansion in Legendre polynomials and solutions are compared to experimental results. The study shows that for nanoparticles with hydrodynamic diameters in the 40-120 nm range, the Fokker-Planck approach that includes polydispersion shows excellent fits to the experimental data.","abstract_html":"As components of dilute ferrofluids, magnetic nanoparticles have been playing an important role in medical industry because of their roles as tracer materials, biomarkers and biosensors. Magnetic particle imaging (MPI) is one of the applications based on the nonlinear response of superparamagnetic iron oxide (SPIO) nanoparticles to external magnetic fields. MPI generates maps of tracer concentration through the use of a static but spatially inhomogeneous field (selection field) and homogeneous oscillating field (drive field). Magnetic particle spectroscopy (MPS) is another interesting application of magnetic particles that measures the magnetic response and the harmonic signal spectrum of the magnetic particles. In the early stage of MPI and MPS, the equilibrium magnetization, or the Langevin magnetization, had been assumed. However, the relaxation effects of the magnetic nanoparticles have to be taken into account due to the existence of fast oscillating magnetic fields in the applications such as MPI and MPS,. In this study, two relaxation mechanisms, Neel relaxation and Brownian relaxation, are introduced into MPI through the Bloch equation. Numerical results indicate that MPI is sensitive to the relaxation time of the nanoparticles. Our simulation also leads to the conclusion that an optimal nanoparticle size can be found in MPI. However, the Bloch equation is a phenomenological equation for studies where the response of the particles is approximately linear. To understand and predict the experimental results with high drive frequency and strong drive field more accurately, two stochastic equations, the Landau-Lifshitz-Gilbert equation and the Fokker-Planck equation, are analytically and numerically studied. The Fokker-Planck equation is solved using an expansion in Legendre polynomials and solutions are compared to experimental results. The study shows that for nanoparticles with hydrodynamic diameters in the 40-120 nm range, the Fokker-Planck approach that includes polydispersion shows excellent fits to the experimental data.","abstract_has_math":false,"creators":["Wu, Yong"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":["Brown, Robert","Martens, Michael"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-08-23","date_published":"2013-08-23","updated_at":"2026-11-26T03:10:36Z","subjects":["Medical Imaging","Physics","Magnetic particle imaging","magnetic particle spectroscopy","magnetic nanoparticle relaxation","Langevin equation","Fokker-Planck equation","Landau-Lifshitz equation","Gilbert equation","Landau-Lifshitz-Gilbert (LLG) equation"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1370865200","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1370865200","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1370865200","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1370865200","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Brown, Robert","Martens, Michael"]},{"key":"dc:creator","label":"Author","values":["Wu, Yong"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013-08-23"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Medical Imaging","Physics","Magnetic particle imaging","magnetic particle spectroscopy","magnetic nanoparticle relaxation","Langevin equation","Fokker-Planck equation","Landau-Lifshitz equation","Gilbert equation","Landau-Lifshitz-Gilbert (LLG) equation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1370865200"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["As components of dilute ferrofluids, magnetic nanoparticles have been playing an important role in medical industry because of their roles as tracer materials, biomarkers and biosensors. Magnetic particle imaging (MPI) is one of the applications based on the nonlinear response of superparamagnetic iron oxide (SPIO) nanoparticles to external magnetic fields. MPI generates maps of tracer concentration through the use of a static but spatially inhomogeneous field (selection field) and homogeneous oscillating field (drive field). Magnetic particle spectroscopy (MPS) is another interesting application of magnetic particles that measures the magnetic response and the harmonic signal spectrum of the magnetic particles. In the early stage of MPI and MPS, the equilibrium magnetization, or the Langevin magnetization, had been assumed. However, the relaxation effects of the magnetic nanoparticles have to be taken into account due to the existence of fast oscillating magnetic fields in the applications such as MPI and MPS,. In this study, two relaxation mechanisms, Neel relaxation and Brownian relaxation, are introduced into MPI through the Bloch equation. Numerical results indicate that MPI is sensitive to the relaxation time of the nanoparticles. Our simulation also leads to the conclusion that an optimal nanoparticle size can be found in MPI. However, the Bloch equation is a phenomenological equation for studies where the response of the particles is approximately linear. To understand and predict the experimental results with high drive frequency and strong drive field more accurately, two stochastic equations, the Landau-Lifshitz-Gilbert equation and the Fokker-Planck equation, are analytically and numerically studied. The Fokker-Planck equation is solved using an expansion in Legendre polynomials and solutions are compared to experimental results. The study shows that for nanoparticles with hydrodynamic diameters in the 40-120 nm range, the Fokker-Planck approach that includes polydispersion shows excellent fits to the experimental data."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.151","2.02 MB"]},{"key":"dc:title","label":"Title","values":["Relaxation Effects in Magnetic Nanoparticle Physics: MPI and MPS Applications"]}]}],"canonical_facts":{"dc:contributor":["Brown, Robert","Martens, Michael"],"dc:creator":["Wu, Yong"],"dc:date":["2013-08-23"],"dc:description":["As components of dilute ferrofluids, magnetic nanoparticles have been playing an important role in medical industry because of their roles as tracer materials, biomarkers and biosensors. Magnetic particle imaging (MPI) is one of the applications based on the nonlinear response of superparamagnetic iron oxide (SPIO) nanoparticles to external magnetic fields. MPI generates maps of tracer concentration through the use of a static but spatially inhomogeneous field (selection field) and homogeneous oscillating field (drive field). Magnetic particle spectroscopy (MPS) is another interesting application of magnetic particles that measures the magnetic response and the harmonic signal spectrum of the magnetic particles. In the early stage of MPI and MPS, the equilibrium magnetization, or the Langevin magnetization, had been assumed. However, the relaxation effects of the magnetic nanoparticles have to be taken into account due to the existence of fast oscillating magnetic fields in the applications such as MPI and MPS,. In this study, two relaxation mechanisms, Neel relaxation and Brownian relaxation, are introduced into MPI through the Bloch equation. Numerical results indicate that MPI is sensitive to the relaxation time of the nanoparticles. Our simulation also leads to the conclusion that an optimal nanoparticle size can be found in MPI. However, the Bloch equation is a phenomenological equation for studies where the response of the particles is approximately linear. To understand and predict the experimental results with high drive frequency and strong drive field more accurately, two stochastic equations, the Landau-Lifshitz-Gilbert equation and the Fokker-Planck equation, are analytically and numerically studied. The Fokker-Planck equation is solved using an expansion in Legendre polynomials and solutions are compared to experimental results. The study shows that for nanoparticles with hydrodynamic diameters in the 40-120 nm range, the Fokker-Planck approach that includes polydispersion shows excellent fits to the experimental data."],"dc:format":["application/pdf","p.151","2.02 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1370865200"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Medical Imaging","Physics","Magnetic particle imaging","magnetic particle spectroscopy","magnetic nanoparticle relaxation","Langevin equation","Fokker-Planck equation","Landau-Lifshitz equation","Gilbert equation","Landau-Lifshitz-Gilbert (LLG) equation"],"dc:title":["Relaxation Effects in Magnetic Nanoparticle Physics: MPI and MPS Applications"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T03:10:36Z"}