{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1377183452"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1377183452","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Wireless MRI Detector Arrays: Technology & Clinical Applications","abstract":"Magnetic resonance imaging (MRI) is an important mainstay in modern clinical care. Detecting the MRI signal with multiple detectors has several benefits, including improving the image signal-to-noise ratio (SNR) and decreasing its acquisition time. These benefits further improve as the number of detectors increases. Therefore, MRI manufacturers have been increasing the number of detectors in phased arrays, with as many as 128 elements. Currently, each detector requires its own receiver chain and cabling, so highly parallel phased arrays require a great deal of cabling. Large amounts of cabling can create multiple problems in MRI, so it is becoming difficult to continue increasing the size of phased arrays. Eliminating these cables through wireless technology would allow manufacturers to continue developing highly parallel phased arrays and further improve image SNR and acquisition speed. This dissertation describes the development of a wireless system for MRI phased arrays. The system was based on Single Sideband Amplitude Modulation (SSB). While operating in the MRI scanner, a single SSB channel preserved the original image SNR by more than 97% for signal dynamic ranges up to 80dB. A simulation method was developed to study the effects of interference when transmitting multiple SSB-modulated MRI signals simultaneously. This simulation was used to determine the optimal channel spacing in an eight-element detector array equipped with SSB, and SNR was preserved by 97% on average. The role of wireless array technology was also explored in two additional applications outside their typical imaging role. The first application was measuring the first order gradient dynamics of a MRI acquisition with an array of transceiver probes equipped with SSB. When expressed as a normalized k-space, residuals between wireless and wired measurements were within 0.55 &#xbf;k, and the majority were below 0.1 &#xbf;k. The second application was a handheld device with wireless micro-coils that controls the image plane during a MRI-guided needle intervention. Device operation was demonstrated by guiding a needle to a target and delivering contrast. The research presented in this dissertation paves the way for integrating wireless technology into highly parallel phased arrays along with other promising MRI applications.","abstract_html":"Magnetic resonance imaging (MRI) is an important mainstay in modern clinical care. Detecting the MRI signal with multiple detectors has several benefits, including improving the image signal-to-noise ratio (SNR) and decreasing its acquisition time. These benefits further improve as the number of detectors increases. Therefore, MRI manufacturers have been increasing the number of detectors in phased arrays, with as many as 128 elements. Currently, each detector requires its own receiver chain and cabling, so highly parallel phased arrays require a great deal of cabling. Large amounts of cabling can create multiple problems in MRI, so it is becoming difficult to continue increasing the size of phased arrays. Eliminating these cables through wireless technology would allow manufacturers to continue developing highly parallel phased arrays and further improve image SNR and acquisition speed. This dissertation describes the development of a wireless system for MRI phased arrays. The system was based on Single Sideband Amplitude Modulation (SSB). While operating in the MRI scanner, a single SSB channel preserved the original image SNR by more than 97% for signal dynamic ranges up to 80dB. A simulation method was developed to study the effects of interference when transmitting multiple SSB-modulated MRI signals simultaneously. This simulation was used to determine the optimal channel spacing in an eight-element detector array equipped with SSB, and SNR was preserved by 97% on average. The role of wireless array technology was also explored in two additional applications outside their typical imaging role. The first application was measuring the first order gradient dynamics of a MRI acquisition with an array of transceiver probes equipped with SSB. When expressed as a normalized k-space, residuals between wireless and wired measurements were within 0.55 &amp;#xbf;k, and the majority were below 0.1 &amp;#xbf;k. The second application was a handheld device with wireless micro-coils that controls the image plane during a MRI-guided needle intervention. Device operation was demonstrated by guiding a needle to a target and delivering contrast. The research presented in this dissertation paves the way for integrating wireless technology into highly parallel phased arrays along with other promising MRI applications.","abstract_has_math":false,"creators":["Riffe, Matthew Joseph"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Griswold, Mark","Seiberlich, Nicole"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-02-21","date_published":"2014-02-21","updated_at":"2026-11-26T04:34:21Z","subjects":["Biomedical Engineering","Medical Imaging","Magnetic Resonance Imaging","MRI","Wireless","Single Sideband Amplitude Modulation","SSB"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1377183452","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1377183452","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1377183452","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1377183452","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Griswold, Mark","Seiberlich, Nicole"]},{"key":"dc:creator","label":"Author","values":["Riffe, Matthew Joseph"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-02-21"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Medical Imaging","Magnetic Resonance Imaging","MRI","Wireless","Single Sideband Amplitude Modulation","SSB"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1377183452"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Magnetic resonance imaging (MRI) is an important mainstay in modern clinical care. Detecting the MRI signal with multiple detectors has several benefits, including improving the image signal-to-noise ratio (SNR) and decreasing its acquisition time. These benefits further improve as the number of detectors increases. Therefore, MRI manufacturers have been increasing the number of detectors in phased arrays, with as many as 128 elements. Currently, each detector requires its own receiver chain and cabling, so highly parallel phased arrays require a great deal of cabling. Large amounts of cabling can create multiple problems in MRI, so it is becoming difficult to continue increasing the size of phased arrays. Eliminating these cables through wireless technology would allow manufacturers to continue developing highly parallel phased arrays and further improve image SNR and acquisition speed. This dissertation describes the development of a wireless system for MRI phased arrays. The system was based on Single Sideband Amplitude Modulation (SSB). While operating in the MRI scanner, a single SSB channel preserved the original image SNR by more than 97% for signal dynamic ranges up to 80dB. A simulation method was developed to study the effects of interference when transmitting multiple SSB-modulated MRI signals simultaneously. This simulation was used to determine the optimal channel spacing in an eight-element detector array equipped with SSB, and SNR was preserved by 97% on average. The role of wireless array technology was also explored in two additional applications outside their typical imaging role. The first application was measuring the first order gradient dynamics of a MRI acquisition with an array of transceiver probes equipped with SSB. When expressed as a normalized k-space, residuals between wireless and wired measurements were within 0.55 &#xbf;k, and the majority were below 0.1 &#xbf;k. The second application was a handheld device with wireless micro-coils that controls the image plane during a MRI-guided needle intervention. Device operation was demonstrated by guiding a needle to a target and delivering contrast. The research presented in this dissertation paves the way for integrating wireless technology into highly parallel phased arrays along with other promising MRI applications."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.179","9.15 MB"]},{"key":"dc:title","label":"Title","values":["Wireless MRI Detector Arrays: Technology & Clinical Applications"]}]}],"canonical_facts":{"dc:contributor":["Griswold, Mark","Seiberlich, Nicole"],"dc:creator":["Riffe, Matthew Joseph"],"dc:date":["2014-02-21"],"dc:description":["Magnetic resonance imaging (MRI) is an important mainstay in modern clinical care. Detecting the MRI signal with multiple detectors has several benefits, including improving the image signal-to-noise ratio (SNR) and decreasing its acquisition time. These benefits further improve as the number of detectors increases. Therefore, MRI manufacturers have been increasing the number of detectors in phased arrays, with as many as 128 elements. Currently, each detector requires its own receiver chain and cabling, so highly parallel phased arrays require a great deal of cabling. Large amounts of cabling can create multiple problems in MRI, so it is becoming difficult to continue increasing the size of phased arrays. Eliminating these cables through wireless technology would allow manufacturers to continue developing highly parallel phased arrays and further improve image SNR and acquisition speed. This dissertation describes the development of a wireless system for MRI phased arrays. The system was based on Single Sideband Amplitude Modulation (SSB). While operating in the MRI scanner, a single SSB channel preserved the original image SNR by more than 97% for signal dynamic ranges up to 80dB. A simulation method was developed to study the effects of interference when transmitting multiple SSB-modulated MRI signals simultaneously. This simulation was used to determine the optimal channel spacing in an eight-element detector array equipped with SSB, and SNR was preserved by 97% on average. The role of wireless array technology was also explored in two additional applications outside their typical imaging role. The first application was measuring the first order gradient dynamics of a MRI acquisition with an array of transceiver probes equipped with SSB. When expressed as a normalized k-space, residuals between wireless and wired measurements were within 0.55 &#xbf;k, and the majority were below 0.1 &#xbf;k. The second application was a handheld device with wireless micro-coils that controls the image plane during a MRI-guided needle intervention. Device operation was demonstrated by guiding a needle to a target and delivering contrast. The research presented in this dissertation paves the way for integrating wireless technology into highly parallel phased arrays along with other promising MRI applications."],"dc:format":["application/pdf","p.179","9.15 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1377183452"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Medical Imaging","Magnetic Resonance Imaging","MRI","Wireless","Single Sideband Amplitude Modulation","SSB"],"dc:title":["Wireless MRI Detector Arrays: Technology & Clinical Applications"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T04:34:21Z"}