{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1386229121"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1386229121","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Nonlinear Feedforward-Feedback Control of an Uncertain, Time-delayed Musculoskeletal Arm Model for use in Functional Electrical Stimulation","abstract":"Using a model-based approach, we designed and evaluated nonlinear combined feedforward-feedback algorithms to control arm movements in the presence of a wide range of perturbations: (1) manipulation of objects of unknown mass, (2) sensor noise, (3) muscle fatigue, (4) model uncertainty with respect to the true inertial properties of the arm and the true muscle dynamics, and (5) input time delays. These algorithms were developed specifically for use in FES neuroprostheses for individuals with paralysis due to spinal cord injury and other neurological disorders. An initial comparison of combined feedforward-feedback proportional-derivative (PD), adaptive control, and sliding mode control showed that input time delays quickly caused instability for all three controllers if feedback gains were chosen too high. Decreasing the feedback gains (i.e., shifting towards feedforward control) re-established stability, but greatly reduced performance as measured by the root-mean-square error between the specified movement intent and the simulated joint angles. Input time delays are unavoidable in FES applications, arising from the muscle dynamics and the relatively low stimulation frequency (i.e. 12Hz) typically used in upper extremity FES neuroprostheses. The destabilizing effects of time delay therefore cannot be ignored. Using a 2DOF musculoskeletal arm model, we designed and evaluated a nonlinear combined feedforward-feedback controller with time delay compensation. In the presence of a typical 80ms time delay, this controller achieved excellent tracking accuracy, both under ideal conditions (shoulder RMSE: 0.27º, elbow RMSE: 0.62º) and in the presence of a wide variety of perturbations expected under normal operating conditions (shoulder RMSE: 2.99º, elbow RMSE: 5.15º). We extended this time delay compensating controller to a more functionally relevant 5DOF arm model. This extended controller achieved stable, accurate tracking, even in the presence of time delay, measurement noise, muscle fatigue and additional loading - but only if the inertial properties of the arm were exactly known. Future research in gravity compensation and adaptation may further improve the robustness of the time delay compensating controller for the 5DOF arm model. This work represents an important step towards a clinically viable controller for upper extremity FES neuroprostheses for human SCI subjects.","abstract_html":"Using a model-based approach, we designed and evaluated nonlinear combined feedforward-feedback algorithms to control arm movements in the presence of a wide range of perturbations: (1) manipulation of objects of unknown mass, (2) sensor noise, (3) muscle fatigue, (4) model uncertainty with respect to the true inertial properties of the arm and the true muscle dynamics, and (5) input time delays. These algorithms were developed specifically for use in FES neuroprostheses for individuals with paralysis due to spinal cord injury and other neurological disorders. An initial comparison of combined feedforward-feedback proportional-derivative (PD), adaptive control, and sliding mode control showed that input time delays quickly caused instability for all three controllers if feedback gains were chosen too high. Decreasing the feedback gains (i.e., shifting towards feedforward control) re-established stability, but greatly reduced performance as measured by the root-mean-square error between the specified movement intent and the simulated joint angles. Input time delays are unavoidable in FES applications, arising from the muscle dynamics and the relatively low stimulation frequency (i.e. 12Hz) typically used in upper extremity FES neuroprostheses. The destabilizing effects of time delay therefore cannot be ignored. Using a 2DOF musculoskeletal arm model, we designed and evaluated a nonlinear combined feedforward-feedback controller with time delay compensation. In the presence of a typical 80ms time delay, this controller achieved excellent tracking accuracy, both under ideal conditions (shoulder RMSE: 0.27º, elbow RMSE: 0.62º) and in the presence of a wide variety of perturbations expected under normal operating conditions (shoulder RMSE: 2.99º, elbow RMSE: 5.15º). We extended this time delay compensating controller to a more functionally relevant 5DOF arm model. This extended controller achieved stable, accurate tracking, even in the presence of time delay, measurement noise, muscle fatigue and additional loading - but only if the inertial properties of the arm were exactly known. Future research in gravity compensation and adaptation may further improve the robustness of the time delay compensating controller for the 5DOF arm model. This work represents an important step towards a clinically viable controller for upper extremity FES neuroprostheses for human SCI subjects.","abstract_has_math":false,"creators":["Cooman, Peter"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Kirsch, Robert"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-02-21","date_published":"2014-02-21","updated_at":"2026-11-26T04:35:38Z","subjects":["Biomedical Engineering","human arm","spinal cord injury","functional electrical stimulation","feedback control","time delay"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1386229121","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1386229121","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1386229121","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1386229121","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kirsch, Robert"]},{"key":"dc:creator","label":"Author","values":["Cooman, Peter"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-02-21"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","human arm","spinal cord injury","functional electrical stimulation","feedback control","time delay"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1386229121"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Using a model-based approach, we designed and evaluated nonlinear combined feedforward-feedback algorithms to control arm movements in the presence of a wide range of perturbations: (1) manipulation of objects of unknown mass, (2) sensor noise, (3) muscle fatigue, (4) model uncertainty with respect to the true inertial properties of the arm and the true muscle dynamics, and (5) input time delays. These algorithms were developed specifically for use in FES neuroprostheses for individuals with paralysis due to spinal cord injury and other neurological disorders. An initial comparison of combined feedforward-feedback proportional-derivative (PD), adaptive control, and sliding mode control showed that input time delays quickly caused instability for all three controllers if feedback gains were chosen too high. Decreasing the feedback gains (i.e., shifting towards feedforward control) re-established stability, but greatly reduced performance as measured by the root-mean-square error between the specified movement intent and the simulated joint angles. Input time delays are unavoidable in FES applications, arising from the muscle dynamics and the relatively low stimulation frequency (i.e. 12Hz) typically used in upper extremity FES neuroprostheses. The destabilizing effects of time delay therefore cannot be ignored. Using a 2DOF musculoskeletal arm model, we designed and evaluated a nonlinear combined feedforward-feedback controller with time delay compensation. In the presence of a typical 80ms time delay, this controller achieved excellent tracking accuracy, both under ideal conditions (shoulder RMSE: 0.27º, elbow RMSE: 0.62º) and in the presence of a wide variety of perturbations expected under normal operating conditions (shoulder RMSE: 2.99º, elbow RMSE: 5.15º). We extended this time delay compensating controller to a more functionally relevant 5DOF arm model. This extended controller achieved stable, accurate tracking, even in the presence of time delay, measurement noise, muscle fatigue and additional loading - but only if the inertial properties of the arm were exactly known. Future research in gravity compensation and adaptation may further improve the robustness of the time delay compensating controller for the 5DOF arm model. This work represents an important step towards a clinically viable controller for upper extremity FES neuroprostheses for human SCI subjects."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.212","5.07 MB"]},{"key":"dc:title","label":"Title","values":["Nonlinear Feedforward-Feedback Control of an Uncertain, Time-delayed Musculoskeletal Arm Model for use in Functional Electrical Stimulation"]}]}],"canonical_facts":{"dc:contributor":["Kirsch, Robert"],"dc:creator":["Cooman, Peter"],"dc:date":["2014-02-21"],"dc:description":["Using a model-based approach, we designed and evaluated nonlinear combined feedforward-feedback algorithms to control arm movements in the presence of a wide range of perturbations: (1) manipulation of objects of unknown mass, (2) sensor noise, (3) muscle fatigue, (4) model uncertainty with respect to the true inertial properties of the arm and the true muscle dynamics, and (5) input time delays. These algorithms were developed specifically for use in FES neuroprostheses for individuals with paralysis due to spinal cord injury and other neurological disorders. An initial comparison of combined feedforward-feedback proportional-derivative (PD), adaptive control, and sliding mode control showed that input time delays quickly caused instability for all three controllers if feedback gains were chosen too high. Decreasing the feedback gains (i.e., shifting towards feedforward control) re-established stability, but greatly reduced performance as measured by the root-mean-square error between the specified movement intent and the simulated joint angles. Input time delays are unavoidable in FES applications, arising from the muscle dynamics and the relatively low stimulation frequency (i.e. 12Hz) typically used in upper extremity FES neuroprostheses. The destabilizing effects of time delay therefore cannot be ignored. Using a 2DOF musculoskeletal arm model, we designed and evaluated a nonlinear combined feedforward-feedback controller with time delay compensation. In the presence of a typical 80ms time delay, this controller achieved excellent tracking accuracy, both under ideal conditions (shoulder RMSE: 0.27º, elbow RMSE: 0.62º) and in the presence of a wide variety of perturbations expected under normal operating conditions (shoulder RMSE: 2.99º, elbow RMSE: 5.15º). We extended this time delay compensating controller to a more functionally relevant 5DOF arm model. This extended controller achieved stable, accurate tracking, even in the presence of time delay, measurement noise, muscle fatigue and additional loading - but only if the inertial properties of the arm were exactly known. Future research in gravity compensation and adaptation may further improve the robustness of the time delay compensating controller for the 5DOF arm model. This work represents an important step towards a clinically viable controller for upper extremity FES neuroprostheses for human SCI subjects."],"dc:format":["application/pdf","p.212","5.07 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1386229121"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","human arm","spinal cord injury","functional electrical stimulation","feedback control","time delay"],"dc:title":["Nonlinear Feedforward-Feedback Control of an Uncertain, Time-delayed Musculoskeletal Arm Model for use in Functional Electrical Stimulation"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T04:35:38Z"}