{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1386343733"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1386343733","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Production of a Viable Product in Magnetic Resonance Imaging Using MgB2","abstract":"In light of uncertainties regarding future helium supply and pricing, the push to eliminate helium dependence in medical imaging has guided research and development of MgB2 superconducting magnets. In the competitive medical imaging market, ability to build an MgB2 MRI does not imply a successful product. The design of a viable product using MgB2 for use in MRI must maximize the product’s value while minimizing the product’s price. Four MRI design options utilizing MgB2 are considered: 1) 1.5T full-body, 2) 1.5T head/extremity, 3) 0.5T head/extremity, and 4) 0.5T head/extremity with an inhomogeneous main field. Each new option represents a sacrifice in value to the customer in terms of bore diameter (2), main field strength (3), and main field homogeneity (4). Of the options, the 1.5T head/extremity MRI offers the greatest price reduction with the smallest value sacrifice, and therefore has the greatest potential for viability in the medical imaging market.","abstract_html":"In light of uncertainties regarding future helium supply and pricing, the push to eliminate helium dependence in medical imaging has guided research and development of MgB2 superconducting magnets. In the competitive medical imaging market, ability to build an MgB2 MRI does not imply a successful product. The design of a viable product using MgB2 for use in MRI must maximize the product’s value while minimizing the product’s price. Four MRI design options utilizing MgB2 are considered: 1) 1.5T full-body, 2) 1.5T head/extremity, 3) 0.5T head/extremity, and 4) 0.5T head/extremity with an inhomogeneous main field. Each new option represents a sacrifice in value to the customer in terms of bore diameter (2), main field strength (3), and main field homogeneity (4). Of the options, the 1.5T head/extremity MRI offers the greatest price reduction with the smallest value sacrifice, and therefore has the greatest potential for viability in the medical imaging market.","abstract_has_math":false,"creators":["Kara, Danielle Christine"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":["Caner, Edward","Martens, Michael"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-02-21","date_published":"2014-02-21","updated_at":"2026-11-26T04:35:38Z","subjects":["Physics","Magnesium Diboride, MRI, Magnetic Resonance Imaging"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1386343733","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1386343733","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1386343733","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1386343733","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Caner, Edward","Martens, Michael"]},{"key":"dc:creator","label":"Author","values":["Kara, Danielle Christine"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-02-21"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics","Magnesium Diboride, MRI, Magnetic Resonance Imaging"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1386343733"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In light of uncertainties regarding future helium supply and pricing, the push to eliminate helium dependence in medical imaging has guided research and development of MgB2 superconducting magnets. In the competitive medical imaging market, ability to build an MgB2 MRI does not imply a successful product. The design of a viable product using MgB2 for use in MRI must maximize the product’s value while minimizing the product’s price. Four MRI design options utilizing MgB2 are considered: 1) 1.5T full-body, 2) 1.5T head/extremity, 3) 0.5T head/extremity, and 4) 0.5T head/extremity with an inhomogeneous main field. Each new option represents a sacrifice in value to the customer in terms of bore diameter (2), main field strength (3), and main field homogeneity (4). Of the options, the 1.5T head/extremity MRI offers the greatest price reduction with the smallest value sacrifice, and therefore has the greatest potential for viability in the medical imaging market."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.76","1.46 MB"]},{"key":"dc:title","label":"Title","values":["Production of a Viable Product in Magnetic Resonance Imaging Using MgB2"]}]}],"canonical_facts":{"dc:contributor":["Caner, Edward","Martens, Michael"],"dc:creator":["Kara, Danielle Christine"],"dc:date":["2014-02-21"],"dc:description":["In light of uncertainties regarding future helium supply and pricing, the push to eliminate helium dependence in medical imaging has guided research and development of MgB2 superconducting magnets. In the competitive medical imaging market, ability to build an MgB2 MRI does not imply a successful product. The design of a viable product using MgB2 for use in MRI must maximize the product’s value while minimizing the product’s price. Four MRI design options utilizing MgB2 are considered: 1) 1.5T full-body, 2) 1.5T head/extremity, 3) 0.5T head/extremity, and 4) 0.5T head/extremity with an inhomogeneous main field. Each new option represents a sacrifice in value to the customer in terms of bore diameter (2), main field strength (3), and main field homogeneity (4). Of the options, the 1.5T head/extremity MRI offers the greatest price reduction with the smallest value sacrifice, and therefore has the greatest potential for viability in the medical imaging market."],"dc:format":["application/pdf","p.76","1.46 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1386343733"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Physics","Magnesium Diboride, MRI, Magnetic Resonance Imaging"],"dc:title":["Production of a Viable Product in Magnetic Resonance Imaging Using MgB2"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T04:35:38Z"}