{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1396887958"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1396887958","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"CHARACTERIZATION OF CARBON FIBER MICROELECTRODES DECORATED WITH PLATINUM NANOPARTICLES","abstract":"Cyclic voltammetry and other analytical techniques are used to characterize carbon fiber microelectrodes with a diameter of 11µm. To identify abnormalities in the seal of the microelectrode, voltammetry in potassium ferricyanide and sodium hydroxide is used. In order to then increase sensitivity to hydrogen peroxide, the microelectrodes are decorated with platinum nanoparticles using a new, more efficient technique which makes use of commercially available suspensions of nanoparticles. Each electrode was then characterized using SEM imaging and EDS analysis. These analyses demonstrated that the new methodology for platinum nanoparticle deposition was very effective in depositing a well dispersed and uniform layer of particles. However the dispersion of the particles was not controlled and proved to limit this method on a commercial scale.","abstract_html":"Cyclic voltammetry and other analytical techniques are used to characterize carbon fiber microelectrodes with a diameter of 11µm. To identify abnormalities in the seal of the microelectrode, voltammetry in potassium ferricyanide and sodium hydroxide is used. In order to then increase sensitivity to hydrogen peroxide, the microelectrodes are decorated with platinum nanoparticles using a new, more efficient technique which makes use of commercially available suspensions of nanoparticles. Each electrode was then characterized using SEM imaging and EDS analysis. These analyses demonstrated that the new methodology for platinum nanoparticle deposition was very effective in depositing a well dispersed and uniform layer of particles. However the dispersion of the particles was not controlled and proved to limit this method on a commercial scale.","abstract_has_math":false,"creators":["Dorflinger, Charles"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":[],"advisors":["Burgess, James","Tochtrop, Greg"],"committee_chairs":["Gray, Thomas"],"committee_members":[],"year":2014,"date_issued":"2014-06-11","date_published":"2014-06-11","updated_at":"2026-11-27T04:39:32Z","subjects":["Analytical Chemistry","Physical Chemistry"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1396887958","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1396887958","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1396887958","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1396887958","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Burgess, James","Tochtrop, Greg"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Gray, Thomas"]},{"key":"dc:creator","label":"Author","values":["Dorflinger, Charles"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-06-11"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Analytical Chemistry","Physical Chemistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1396887958"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Cyclic voltammetry and other analytical techniques are used to characterize carbon fiber microelectrodes with a diameter of 11µm. To identify abnormalities in the seal of the microelectrode, voltammetry in potassium ferricyanide and sodium hydroxide is used. In order to then increase sensitivity to hydrogen peroxide, the microelectrodes are decorated with platinum nanoparticles using a new, more efficient technique which makes use of commercially available suspensions of nanoparticles. Each electrode was then characterized using SEM imaging and EDS analysis. These analyses demonstrated that the new methodology for platinum nanoparticle deposition was very effective in depositing a well dispersed and uniform layer of particles. However the dispersion of the particles was not controlled and proved to limit this method on a commercial scale."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","2.43 MB"]},{"key":"dc:title","label":"Title","values":["CHARACTERIZATION OF CARBON FIBER MICROELECTRODES DECORATED WITH PLATINUM NANOPARTICLES"]}]}],"canonical_facts":{"dc:contributor.advisor":["Burgess, James","Tochtrop, Greg"],"dc:contributor.committeechair":["Gray, Thomas"],"dc:creator":["Dorflinger, Charles"],"dc:date":["2014-06-11"],"dc:description":["Cyclic voltammetry and other analytical techniques are used to characterize carbon fiber microelectrodes with a diameter of 11µm. To identify abnormalities in the seal of the microelectrode, voltammetry in potassium ferricyanide and sodium hydroxide is used. In order to then increase sensitivity to hydrogen peroxide, the microelectrodes are decorated with platinum nanoparticles using a new, more efficient technique which makes use of commercially available suspensions of nanoparticles. Each electrode was then characterized using SEM imaging and EDS analysis. These analyses demonstrated that the new methodology for platinum nanoparticle deposition was very effective in depositing a well dispersed and uniform layer of particles. However the dispersion of the particles was not controlled and proved to limit this method on a commercial scale."],"dc:format":["application/pdf","2.43 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1396887958"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Analytical Chemistry","Physical Chemistry"],"dc:title":["CHARACTERIZATION OF CARBON FIBER MICROELECTRODES DECORATED WITH PLATINUM NANOPARTICLES"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:39:32Z"}