{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1396888841"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1396888841","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Thermal Characteristics of Microinverters on Dual-axis Trackers","abstract":"The thermal characteristics of microinverters on dual-axis trackers operating underreal-world conditions were analyzed using a statistical analytical approach. 24 microinvertersconnected to 8 different brands of photovoltaic (PV) modules were analyzedfrom July through October 2013 at the Solar Durability and Lifetime Extension (SDLE)SunFarm at Case Western Reserve University (latitude 41.5<sup>0</sup>, longitude -81.64<sup>0</sup>). Exploratorydata analysis shows that the microinverters&#x2019; temperature is strongly correlatedwith ambient temperature and PV module temperature, and moderately correlated withirradiance and AC power. Ambient temperature is the influencing factor under conditionsof low irradiance in morning hours, when the irradiance is below 60W/m<sup>2</sup>. Noontimedata analysis reveals that the microinverters thermal behavior is more strongly influencedby PV module temperature than AC power. Using a Euclidean distance measuringprinciple and average linkage criteria, a hierarchical clustering technique was alsoapplied to noontime microinverter temperature data to group the similarly behaved microinverters.Microinverter temperature clustering shows that the clustering groups aremore strongly influenced by PV module temperature than AC power. A linear regressionmodel was developed to predict the temperature of the microinverters connected to differentbrands PV modules. The predictive model is a function of ambient temperature,PV module temperature, irradiance, AC power data, and the interaction between power,irradiance and module temperature. The difference between actual microinverter andpredicted microinverter temperature lies between 0.4<sup>0</sup>C to 1.6<sup>0</sup>C at a 95% confidenceinterval.","abstract_html":"The thermal characteristics of microinverters on dual-axis trackers operating underreal-world conditions were analyzed using a statistical analytical approach. 24 microinvertersconnected to 8 different brands of photovoltaic (PV) modules were analyzedfrom July through October 2013 at the Solar Durability and Lifetime Extension (SDLE)SunFarm at Case Western Reserve University (latitude 41.5&lt;sup&gt;0&lt;/sup&gt;, longitude -81.64&lt;sup&gt;0&lt;/sup&gt;). Exploratorydata analysis shows that the microinverters&amp;#x2019; temperature is strongly correlatedwith ambient temperature and PV module temperature, and moderately correlated withirradiance and AC power. Ambient temperature is the influencing factor under conditionsof low irradiance in morning hours, when the irradiance is below 60W/m&lt;sup&gt;2&lt;/sup&gt;. Noontimedata analysis reveals that the microinverters thermal behavior is more strongly influencedby PV module temperature than AC power. Using a Euclidean distance measuringprinciple and average linkage criteria, a hierarchical clustering technique was alsoapplied to noontime microinverter temperature data to group the similarly behaved microinverters.Microinverter temperature clustering shows that the clustering groups aremore strongly influenced by PV module temperature than AC power. A linear regressionmodel was developed to predict the temperature of the microinverters connected to differentbrands PV modules. The predictive model is a function of ambient temperature,PV module temperature, irradiance, AC power data, and the interaction between power,irradiance and module temperature. The difference between actual microinverter andpredicted microinverter temperature lies between 0.4&lt;sup&gt;0&lt;/sup&gt;C to 1.6&lt;sup&gt;0&lt;/sup&gt;C at a 95% confidenceinterval.","abstract_has_math":false,"creators":["Hossain, Mohammad Akram"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences","degree_level":"masters","degree_discipline":"EMC - Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Abramson, Alexis"],"committee_members":[],"year":2014,"date_issued":"2014-06-12","date_published":"2014-06-12","updated_at":"2026-11-27T04:39:32Z","subjects":["Mechanical Engineering","Microinverter, Reliability, Thermal Model"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1396888841","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1396888841","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1396888841","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1396888841","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Abramson, Alexis"]},{"key":"dc:creator","label":"Author","values":["Hossain, Mohammad Akram"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-06-12"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","Microinverter, Reliability, Thermal Model"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1396888841"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The thermal characteristics of microinverters on dual-axis trackers operating underreal-world conditions were analyzed using a statistical analytical approach. 24 microinvertersconnected to 8 different brands of photovoltaic (PV) modules were analyzedfrom July through October 2013 at the Solar Durability and Lifetime Extension (SDLE)SunFarm at Case Western Reserve University (latitude 41.5<sup>0</sup>, longitude -81.64<sup>0</sup>). Exploratorydata analysis shows that the microinverters&#x2019; temperature is strongly correlatedwith ambient temperature and PV module temperature, and moderately correlated withirradiance and AC power. Ambient temperature is the influencing factor under conditionsof low irradiance in morning hours, when the irradiance is below 60W/m<sup>2</sup>. Noontimedata analysis reveals that the microinverters thermal behavior is more strongly influencedby PV module temperature than AC power. Using a Euclidean distance measuringprinciple and average linkage criteria, a hierarchical clustering technique was alsoapplied to noontime microinverter temperature data to group the similarly behaved microinverters.Microinverter temperature clustering shows that the clustering groups aremore strongly influenced by PV module temperature than AC power. A linear regressionmodel was developed to predict the temperature of the microinverters connected to differentbrands PV modules. The predictive model is a function of ambient temperature,PV module temperature, irradiance, AC power data, and the interaction between power,irradiance and module temperature. The difference between actual microinverter andpredicted microinverter temperature lies between 0.4<sup>0</sup>C to 1.6<sup>0</sup>C at a 95% confidenceinterval."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","5.09 MB"]},{"key":"dc:title","label":"Title","values":["Thermal Characteristics of Microinverters on Dual-axis Trackers"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Abramson, Alexis"],"dc:creator":["Hossain, Mohammad Akram"],"dc:date":["2014-06-12"],"dc:description":["The thermal characteristics of microinverters on dual-axis trackers operating underreal-world conditions were analyzed using a statistical analytical approach. 24 microinvertersconnected to 8 different brands of photovoltaic (PV) modules were analyzedfrom July through October 2013 at the Solar Durability and Lifetime Extension (SDLE)SunFarm at Case Western Reserve University (latitude 41.5<sup>0</sup>, longitude -81.64<sup>0</sup>). Exploratorydata analysis shows that the microinverters&#x2019; temperature is strongly correlatedwith ambient temperature and PV module temperature, and moderately correlated withirradiance and AC power. Ambient temperature is the influencing factor under conditionsof low irradiance in morning hours, when the irradiance is below 60W/m<sup>2</sup>. Noontimedata analysis reveals that the microinverters thermal behavior is more strongly influencedby PV module temperature than AC power. Using a Euclidean distance measuringprinciple and average linkage criteria, a hierarchical clustering technique was alsoapplied to noontime microinverter temperature data to group the similarly behaved microinverters.Microinverter temperature clustering shows that the clustering groups aremore strongly influenced by PV module temperature than AC power. A linear regressionmodel was developed to predict the temperature of the microinverters connected to differentbrands PV modules. The predictive model is a function of ambient temperature,PV module temperature, irradiance, AC power data, and the interaction between power,irradiance and module temperature. The difference between actual microinverter andpredicted microinverter temperature lies between 0.4<sup>0</sup>C to 1.6<sup>0</sup>C at a 95% confidenceinterval."],"dc:format":["application/pdf","5.09 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1396888841"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","Microinverter, Reliability, Thermal Model"],"dc:title":["Thermal Characteristics of Microinverters on Dual-axis Trackers"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:39:32Z"}