{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1401707860"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1401707860","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"A Real-Time Human Posture Classifier and Fall-Detector","abstract":"There is a growing demand on human activity recognition and remote wellness monitoring in modern societies. Related algorithms and hardware platforms have been intensively researched during the past decade. This work presents a wearable system for real-time human activity classification and fall detection. As the major part of this system, several algorithms are designed for feature extraction, vertical displacement estimation, and posture classification, and implemented in a customized wearable embedded platform. This battery-powered device has been tested on both undergraduate/graduate students and the elderly. The automatically logged activity reports in the testing are compared with video clips, manually logged activity, and the report from three different commercially available activity trackers. The testing results show up to 89.96% of second-by-second accuracy on daily activities, 75.2% fall detection sensitivity, and 99.85% fall detection specificity.","abstract_html":"There is a growing demand on human activity recognition and remote wellness monitoring in modern societies. Related algorithms and hardware platforms have been intensively researched during the past decade. This work presents a wearable system for real-time human activity classification and fall detection. As the major part of this system, several algorithms are designed for feature extraction, vertical displacement estimation, and posture classification, and implemented in a customized wearable embedded platform. This battery-powered device has been tested on both undergraduate/graduate students and the elderly. The automatically logged activity reports in the testing are compared with video clips, manually logged activity, and the report from three different commercially available activity trackers. The testing results show up to 89.96% of second-by-second accuracy on daily activities, 75.2% fall detection sensitivity, and 99.85% fall detection specificity.","abstract_has_math":false,"creators":["Lin, Chia-Hua"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"EECS - Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Mehregany, Mehran"],"committee_chairs":["Mehregany, Mehran"],"committee_members":[],"year":2014,"date_issued":"2014-09-02","date_published":"2014-09-02","updated_at":"2026-11-27T04:39:41Z","subjects":["Electrical Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1401707860","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1401707860","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1401707860","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1401707860","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mehregany, Mehran"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Mehregany, Mehran"]},{"key":"dc:creator","label":"Author","values":["Lin, Chia-Hua"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-09-02"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1401707860"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["There is a growing demand on human activity recognition and remote wellness monitoring in modern societies. Related algorithms and hardware platforms have been intensively researched during the past decade. This work presents a wearable system for real-time human activity classification and fall detection. As the major part of this system, several algorithms are designed for feature extraction, vertical displacement estimation, and posture classification, and implemented in a customized wearable embedded platform. This battery-powered device has been tested on both undergraduate/graduate students and the elderly. The automatically logged activity reports in the testing are compared with video clips, manually logged activity, and the report from three different commercially available activity trackers. The testing results show up to 89.96% of second-by-second accuracy on daily activities, 75.2% fall detection sensitivity, and 99.85% fall detection specificity."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.142","4. MB"]},{"key":"dc:title","label":"Title","values":["A Real-Time Human Posture Classifier and Fall-Detector"]}]}],"canonical_facts":{"dc:contributor.advisor":["Mehregany, Mehran"],"dc:contributor.committeechair":["Mehregany, Mehran"],"dc:creator":["Lin, Chia-Hua"],"dc:date":["2014-09-02"],"dc:description":["There is a growing demand on human activity recognition and remote wellness monitoring in modern societies. Related algorithms and hardware platforms have been intensively researched during the past decade. This work presents a wearable system for real-time human activity classification and fall detection. As the major part of this system, several algorithms are designed for feature extraction, vertical displacement estimation, and posture classification, and implemented in a customized wearable embedded platform. This battery-powered device has been tested on both undergraduate/graduate students and the elderly. The automatically logged activity reports in the testing are compared with video clips, manually logged activity, and the report from three different commercially available activity trackers. The testing results show up to 89.96% of second-by-second accuracy on daily activities, 75.2% fall detection sensitivity, and 99.85% fall detection specificity."],"dc:format":["application/pdf","p.142","4. MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1401707860"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Electrical Engineering"],"dc:title":["A Real-Time Human Posture Classifier and Fall-Detector"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - Electrical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:39:41Z"}