{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1402055149"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1402055149","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"A LABORATORY SCALE STUDY OF INTUMESCENT COATINGS FOR PROTECTION OF BUILDING STRUCTURE MEMBERS FROM FIRES","abstract":"Intumescent coatings have long been used as effective methods for long-term passive fire protection for buildings. However, much is still unknown about these coatings making it that large scale testing of fully coated steel beams necessary for coating certification. If a coating fails the certification test this comes at a large monetary cost with nothing gained. Thus, a laboratory-scale test that can help predict if a coating will pass the large scale test was studied. There were two main goals: to design and build an apparatus to collect many different types of data all at once from a single test and to perform tests on different samples to gain a better understanding of intumescent coatings. To perform the study, an apparatus was built that was able to maintain a constant heat flux to a samples surface even as the surface location changed. Three different coatings were tested while varying different parameters such as applied heat flux, coating thickness, and plate thickness, while measuring mass loss, expansion, temperature, and heat flux through the samples. By using the tests a better understanding of how the intumescents react to varying heat fluxes was able to be seen along with different trends and behavior patterns of different coatings.","abstract_html":"Intumescent coatings have long been used as effective methods for long-term passive fire protection for buildings. However, much is still unknown about these coatings making it that large scale testing of fully coated steel beams necessary for coating certification. If a coating fails the certification test this comes at a large monetary cost with nothing gained. Thus, a laboratory-scale test that can help predict if a coating will pass the large scale test was studied. There were two main goals: to design and build an apparatus to collect many different types of data all at once from a single test and to perform tests on different samples to gain a better understanding of intumescent coatings. To perform the study, an apparatus was built that was able to maintain a constant heat flux to a samples surface even as the surface location changed. Three different coatings were tested while varying different parameters such as applied heat flux, coating thickness, and plate thickness, while measuring mass loss, expansion, temperature, and heat flux through the samples. By using the tests a better understanding of how the intumescents react to varying heat fluxes was able to be seen along with different trends and behavior patterns of different coatings.","abstract_has_math":false,"creators":["Fry, Zachary S."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EMC - Aerospace Engineering","degree_department":null,"school":null,"contributors":["Takahashi, Fumiaki","T'ien, James"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-08-29","date_published":"2014-08-29","updated_at":"2026-11-26T05:18:36Z","subjects":["Aerospace Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1402055149","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1402055149","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1402055149","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1402055149","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Takahashi, Fumiaki","T'ien, James"]},{"key":"dc:creator","label":"Author","values":["Fry, Zachary S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-08-29"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EMC - Aerospace Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Aerospace Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1402055149"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Intumescent coatings have long been used as effective methods for long-term passive fire protection for buildings. However, much is still unknown about these coatings making it that large scale testing of fully coated steel beams necessary for coating certification. If a coating fails the certification test this comes at a large monetary cost with nothing gained. Thus, a laboratory-scale test that can help predict if a coating will pass the large scale test was studied. There were two main goals: to design and build an apparatus to collect many different types of data all at once from a single test and to perform tests on different samples to gain a better understanding of intumescent coatings. To perform the study, an apparatus was built that was able to maintain a constant heat flux to a samples surface even as the surface location changed. Three different coatings were tested while varying different parameters such as applied heat flux, coating thickness, and plate thickness, while measuring mass loss, expansion, temperature, and heat flux through the samples. By using the tests a better understanding of how the intumescents react to varying heat fluxes was able to be seen along with different trends and behavior patterns of different coatings."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","4.22 MB"]},{"key":"dc:title","label":"Title","values":["A LABORATORY SCALE STUDY OF INTUMESCENT COATINGS FOR PROTECTION OF BUILDING STRUCTURE MEMBERS FROM FIRES"]}]}],"canonical_facts":{"dc:contributor":["Takahashi, Fumiaki","T'ien, James"],"dc:creator":["Fry, Zachary S."],"dc:date":["2014-08-29"],"dc:description":["Intumescent coatings have long been used as effective methods for long-term passive fire protection for buildings. However, much is still unknown about these coatings making it that large scale testing of fully coated steel beams necessary for coating certification. If a coating fails the certification test this comes at a large monetary cost with nothing gained. Thus, a laboratory-scale test that can help predict if a coating will pass the large scale test was studied. There were two main goals: to design and build an apparatus to collect many different types of data all at once from a single test and to perform tests on different samples to gain a better understanding of intumescent coatings. To perform the study, an apparatus was built that was able to maintain a constant heat flux to a samples surface even as the surface location changed. Three different coatings were tested while varying different parameters such as applied heat flux, coating thickness, and plate thickness, while measuring mass loss, expansion, temperature, and heat flux through the samples. By using the tests a better understanding of how the intumescents react to varying heat fluxes was able to be seen along with different trends and behavior patterns of different coatings."],"dc:format":["application/pdf","4.22 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1402055149"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Aerospace Engineering"],"dc:title":["A LABORATORY SCALE STUDY OF INTUMESCENT COATINGS FOR PROTECTION OF BUILDING STRUCTURE MEMBERS FROM FIRES"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EMC - Aerospace Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-26T05:18:36Z"}