{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1402058570"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1402058570","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"OPTIMIZING RF AND GRADIENT COILS IN MRI","abstract":"In this dissertation, several topics on gradient and RF coils in MRI system are studied. Chapter 1 provides an introduction to basics of MRI. Chapter 2 and Chapter 3 focus on methods of eddy current and heat calculation induced by a gradient coil system. A strip model is studied in detail, and effective ways to suppress the heating on the strip are found which serves as a basis for Chapter 4. In chapter 4, guidelines are provided for optimizing slit patterns in radio-frequency (RF) shields. In Chapter 5, acoustic noise induced by gradient system is studied; an acoustic suppression model with modifications of sequence shape is applied, whereby one can suppress several significant vibration modes in kHz range. In Chapter 6, we investigated RF induced heating effect with FDTD simulations. A model for a guidewire inside a plate phantom is studied in detail. Pronounced heating effect is found close to the tip of the guidewire. Specific absorption rate (SAR) levels are calculated for 6 different phase configurations, and compared with both quasi-static calculations and temperature measurements. We found that the quasi-static calculation can serve as an efficient and rapidly applied temperature guide, which can be integrated into a quadraticxxioptimization algorithm for the suppression of the RF induced heating effect. In Chapter 7, noise correlations between different RF phased-array channels are studied. Both quasi-static and FEM full-wave simulations are performed to show the inaccuracy of quasi-static calculation. A simple model for calculating the noise correlation between RF receiver coils is proposed and tested. We find out that the two correlation mechanisms correspond to the resistive and reactive parts of inductive voltage, respectively. This method offers a convenient way of carrying out noise correlation calculations for RF receiver coils (surface or volume) without performing electric field integrations over the whole sample.","abstract_html":"In this dissertation, several topics on gradient and RF coils in MRI system are studied. Chapter 1 provides an introduction to basics of MRI. Chapter 2 and Chapter 3 focus on methods of eddy current and heat calculation induced by a gradient coil system. A strip model is studied in detail, and effective ways to suppress the heating on the strip are found which serves as a basis for Chapter 4. In chapter 4, guidelines are provided for optimizing slit patterns in radio-frequency (RF) shields. In Chapter 5, acoustic noise induced by gradient system is studied; an acoustic suppression model with modifications of sequence shape is applied, whereby one can suppress several significant vibration modes in kHz range. In Chapter 6, we investigated RF induced heating effect with FDTD simulations. A model for a guidewire inside a plate phantom is studied in detail. Pronounced heating effect is found close to the tip of the guidewire. Specific absorption rate (SAR) levels are calculated for 6 different phase configurations, and compared with both quasi-static calculations and temperature measurements. We found that the quasi-static calculation can serve as an efficient and rapidly applied temperature guide, which can be integrated into a quadraticxxioptimization algorithm for the suppression of the RF induced heating effect. In Chapter 7, noise correlations between different RF phased-array channels are studied. Both quasi-static and FEM full-wave simulations are performed to show the inaccuracy of quasi-static calculation. A simple model for calculating the noise correlation between RF receiver coils is proposed and tested. We find out that the two correlation mechanisms correspond to the resistive and reactive parts of inductive voltage, respectively. This method offers a convenient way of carrying out noise correlation calculations for RF receiver coils (surface or volume) without performing electric field integrations over the whole sample.","abstract_has_math":false,"creators":["Yao, Zhen"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Brown, Robert"],"committee_members":[],"year":2014,"date_issued":"2014-09-02","date_published":"2014-09-02","updated_at":"2026-11-27T04:39:45Z","subjects":["Medical Imaging","Physics"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1402058570","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1402058570","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1402058570","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1402058570","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Brown, Robert"]},{"key":"dc:creator","label":"Author","values":["Yao, Zhen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-09-02"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Medical Imaging","Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1402058570"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In this dissertation, several topics on gradient and RF coils in MRI system are studied. Chapter 1 provides an introduction to basics of MRI. Chapter 2 and Chapter 3 focus on methods of eddy current and heat calculation induced by a gradient coil system. A strip model is studied in detail, and effective ways to suppress the heating on the strip are found which serves as a basis for Chapter 4. In chapter 4, guidelines are provided for optimizing slit patterns in radio-frequency (RF) shields. In Chapter 5, acoustic noise induced by gradient system is studied; an acoustic suppression model with modifications of sequence shape is applied, whereby one can suppress several significant vibration modes in kHz range. In Chapter 6, we investigated RF induced heating effect with FDTD simulations. A model for a guidewire inside a plate phantom is studied in detail. Pronounced heating effect is found close to the tip of the guidewire. Specific absorption rate (SAR) levels are calculated for 6 different phase configurations, and compared with both quasi-static calculations and temperature measurements. We found that the quasi-static calculation can serve as an efficient and rapidly applied temperature guide, which can be integrated into a quadraticxxioptimization algorithm for the suppression of the RF induced heating effect. In Chapter 7, noise correlations between different RF phased-array channels are studied. Both quasi-static and FEM full-wave simulations are performed to show the inaccuracy of quasi-static calculation. A simple model for calculating the noise correlation between RF receiver coils is proposed and tested. We find out that the two correlation mechanisms correspond to the resistive and reactive parts of inductive voltage, respectively. This method offers a convenient way of carrying out noise correlation calculations for RF receiver coils (surface or volume) without performing electric field integrations over the whole sample."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.155","5.26 MB"]},{"key":"dc:title","label":"Title","values":["OPTIMIZING RF AND GRADIENT COILS IN MRI"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Brown, Robert"],"dc:creator":["Yao, Zhen"],"dc:date":["2014-09-02"],"dc:description":["In this dissertation, several topics on gradient and RF coils in MRI system are studied. Chapter 1 provides an introduction to basics of MRI. Chapter 2 and Chapter 3 focus on methods of eddy current and heat calculation induced by a gradient coil system. A strip model is studied in detail, and effective ways to suppress the heating on the strip are found which serves as a basis for Chapter 4. In chapter 4, guidelines are provided for optimizing slit patterns in radio-frequency (RF) shields. In Chapter 5, acoustic noise induced by gradient system is studied; an acoustic suppression model with modifications of sequence shape is applied, whereby one can suppress several significant vibration modes in kHz range. In Chapter 6, we investigated RF induced heating effect with FDTD simulations. A model for a guidewire inside a plate phantom is studied in detail. Pronounced heating effect is found close to the tip of the guidewire. Specific absorption rate (SAR) levels are calculated for 6 different phase configurations, and compared with both quasi-static calculations and temperature measurements. We found that the quasi-static calculation can serve as an efficient and rapidly applied temperature guide, which can be integrated into a quadraticxxioptimization algorithm for the suppression of the RF induced heating effect. In Chapter 7, noise correlations between different RF phased-array channels are studied. Both quasi-static and FEM full-wave simulations are performed to show the inaccuracy of quasi-static calculation. A simple model for calculating the noise correlation between RF receiver coils is proposed and tested. We find out that the two correlation mechanisms correspond to the resistive and reactive parts of inductive voltage, respectively. This method offers a convenient way of carrying out noise correlation calculations for RF receiver coils (surface or volume) without performing electric field integrations over the whole sample."],"dc:format":["application/pdf","p.155","5.26 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1402058570"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Medical Imaging","Physics"],"dc:title":["OPTIMIZING RF AND GRADIENT COILS IN MRI"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:39:45Z"}