{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1402066531"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1402066531","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Contactless Radio Frequency Probes for High Temperature Characterization of Microwave Integrated Circuits","abstract":"A method of characterizing microwave integrated circuits (MICs) at high temperature by way of a contactless probing method is developed. Current methods for characterizing MICs include probing circuits use either ground-signal-ground (GSG) or ground-signal (GS) contact probes that are not designed to withstand exposure to high temperatures. Although specially made GSG and GS probes for high temperature use have been developed, they lack the robustness for repeated use and often damage the device under test (DUT). A contactless approach was developed to address these limitations. In this work, a contactless probe design based on a microstrip transmission line that electromagnetically couples RF signals to a second microstrip transmission line connected in series to DUT was developed. To verify the efficacy of these contactless RF probes at high temperatures, three different circuits were designed, fabricated, and characterized at temperatures from 25 to 200 degrees C.","abstract_html":"A method of characterizing microwave integrated circuits (MICs) at high temperature by way of a contactless probing method is developed. Current methods for characterizing MICs include probing circuits use either ground-signal-ground (GSG) or ground-signal (GS) contact probes that are not designed to withstand exposure to high temperatures. Although specially made GSG and GS probes for high temperature use have been developed, they lack the robustness for repeated use and often damage the device under test (DUT). A contactless approach was developed to address these limitations. In this work, a contactless probe design based on a microstrip transmission line that electromagnetically couples RF signals to a second microstrip transmission line connected in series to DUT was developed. To verify the efficacy of these contactless RF probes at high temperatures, three different circuits were designed, fabricated, and characterized at temperatures from 25 to 200 degrees C.","abstract_has_math":false,"creators":["Jordan, Jennifer L."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"EECS - Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Zorman, Christian"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-08-29","date_published":"2014-08-29","updated_at":"2026-11-27T04:39:45Z","subjects":["Electrical Engineering","RF Probes, microwaves, microstrip, characterization techniques, microwave integrated circuits"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1402066531","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1402066531","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1402066531","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1402066531","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zorman, Christian"]},{"key":"dc:creator","label":"Author","values":["Jordan, Jennifer L."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-08-29"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["EECS - Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering","RF Probes, microwaves, microstrip, characterization techniques, microwave integrated circuits"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1402066531"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A method of characterizing microwave integrated circuits (MICs) at high temperature by way of a contactless probing method is developed. Current methods for characterizing MICs include probing circuits use either ground-signal-ground (GSG) or ground-signal (GS) contact probes that are not designed to withstand exposure to high temperatures. Although specially made GSG and GS probes for high temperature use have been developed, they lack the robustness for repeated use and often damage the device under test (DUT). A contactless approach was developed to address these limitations. In this work, a contactless probe design based on a microstrip transmission line that electromagnetically couples RF signals to a second microstrip transmission line connected in series to DUT was developed. To verify the efficacy of these contactless RF probes at high temperatures, three different circuits were designed, fabricated, and characterized at temperatures from 25 to 200 degrees C."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.70","2.32 MB"]},{"key":"dc:title","label":"Title","values":["Contactless Radio Frequency Probes for High Temperature Characterization of Microwave Integrated Circuits"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zorman, Christian"],"dc:creator":["Jordan, Jennifer L."],"dc:date":["2014-08-29"],"dc:description":["A method of characterizing microwave integrated circuits (MICs) at high temperature by way of a contactless probing method is developed. Current methods for characterizing MICs include probing circuits use either ground-signal-ground (GSG) or ground-signal (GS) contact probes that are not designed to withstand exposure to high temperatures. Although specially made GSG and GS probes for high temperature use have been developed, they lack the robustness for repeated use and often damage the device under test (DUT). A contactless approach was developed to address these limitations. In this work, a contactless probe design based on a microstrip transmission line that electromagnetically couples RF signals to a second microstrip transmission line connected in series to DUT was developed. To verify the efficacy of these contactless RF probes at high temperatures, three different circuits were designed, fabricated, and characterized at temperatures from 25 to 200 degrees C."],"dc:format":["application/pdf","p.70","2.32 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1402066531"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Electrical Engineering","RF Probes, microwaves, microstrip, characterization techniques, microwave integrated circuits"],"dc:title":["Contactless Radio Frequency Probes for High Temperature Characterization of Microwave Integrated Circuits"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["EECS - Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:39:45Z"}