{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1405002859"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1405002859","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Iron-Ligand Electrokinetics towards an all-Iron Hybrid Redox Flow Battery","abstract":"Flow batteries as a large scale energy storage technology have seen a renewed interest in recent years with the implementation of renewable energy sources on the grid. One such flow battery is the all-iron chemistry. The all-iron flow battery utilizes the Fe II/III redox couple as the positive electrode and the Fe II/0 reaction as the negative electrode. Iron plating in the negative electrode occurs in the cell stack, necessitating intelligent design of the porous electrode structure to maximize plating density, and thus energy storage density. Due to the negative potential of the iron plating reaction, hydrogen evolution is a main concern in long term operation of the all-iron flow battery. As hydrogen evolves the electrolyte pH will rise, causing precipitation of the ferric ions in the positive electrolyte.This research addresses three critical aspects of the chemistry and design of the all-iron flow battery. First, to increase the ferric ion solubility in relatively high pHs (pH 2 – 3), complexing ligands are considered as an electrolyte additive. Kinetic and mass transfer behavior of several iron-ligand complexes are examined. An electrolyte containing a 0.5:1 glycine to iron ratio showed Fe<sup>3+</sup> solubility at pHs greater than 2.5 and reasonable kinetic performance on a glassy carbon electrode. Modeling of the equilibrium species in an iron-glycine solution is used to design an electrolyte with the desired solubility and concentration of Fe<sup>3+</sup>. Second, the iron deposition reaction is considered in conjunction with added ligand. Further suppression of hydrogen evolution was also considered through the use of various supporting electrolytes. High concentrations of chloride ions were found to hinder hydrogen evolution in the negative electrolyte, both on an iron rod electrode and in an all-iron flow battery. Third, the plating capacity of the negative deposition electrode is considered. Six three dimensional electrode structures are presented, and an achievable plating density of 150 mAh/cm<sup>2</sup> is demonstrated in two separate electrode structures. Cycling of an all-iron flow battery with a voltaic efficiency of 80% is demonstrated.","abstract_html":"Flow batteries as a large scale energy storage technology have seen a renewed interest in recent years with the implementation of renewable energy sources on the grid. One such flow battery is the all-iron chemistry. The all-iron flow battery utilizes the Fe II/III redox couple as the positive electrode and the Fe II/0 reaction as the negative electrode. Iron plating in the negative electrode occurs in the cell stack, necessitating intelligent design of the porous electrode structure to maximize plating density, and thus energy storage density. Due to the negative potential of the iron plating reaction, hydrogen evolution is a main concern in long term operation of the all-iron flow battery. As hydrogen evolves the electrolyte pH will rise, causing precipitation of the ferric ions in the positive electrolyte.This research addresses three critical aspects of the chemistry and design of the all-iron flow battery. First, to increase the ferric ion solubility in relatively high pHs (pH 2 – 3), complexing ligands are considered as an electrolyte additive. Kinetic and mass transfer behavior of several iron-ligand complexes are examined. An electrolyte containing a 0.5:1 glycine to iron ratio showed Fe&lt;sup&gt;3+&lt;/sup&gt; solubility at pHs greater than 2.5 and reasonable kinetic performance on a glassy carbon electrode. Modeling of the equilibrium species in an iron-glycine solution is used to design an electrolyte with the desired solubility and concentration of Fe&lt;sup&gt;3+&lt;/sup&gt;. Second, the iron deposition reaction is considered in conjunction with added ligand. Further suppression of hydrogen evolution was also considered through the use of various supporting electrolytes. High concentrations of chloride ions were found to hinder hydrogen evolution in the negative electrolyte, both on an iron rod electrode and in an all-iron flow battery. Third, the plating capacity of the negative deposition electrode is considered. Six three dimensional electrode structures are presented, and an achievable plating density of 150 mAh/cm&lt;sup&gt;2&lt;/sup&gt; is demonstrated in two separate electrode structures. Cycling of an all-iron flow battery with a voltaic efficiency of 80% is demonstrated.","abstract_has_math":false,"creators":["Hawthorne, Krista Leigh"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Savinell, Robert","Wainright, Jesse"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-09-02","date_published":"2014-09-02","updated_at":"2026-11-27T04:39:45Z","subjects":["Chemical Engineering","Energy","Flow Battery","Hybrid Flow Battery","Energy Storage"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1405002859","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1405002859","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1405002859","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1405002859","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Savinell, Robert","Wainright, Jesse"]},{"key":"dc:creator","label":"Author","values":["Hawthorne, Krista Leigh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-09-02"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemical Engineering","Energy","Flow Battery","Hybrid Flow Battery","Energy Storage"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1405002859"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Flow batteries as a large scale energy storage technology have seen a renewed interest in recent years with the implementation of renewable energy sources on the grid. One such flow battery is the all-iron chemistry. The all-iron flow battery utilizes the Fe II/III redox couple as the positive electrode and the Fe II/0 reaction as the negative electrode. Iron plating in the negative electrode occurs in the cell stack, necessitating intelligent design of the porous electrode structure to maximize plating density, and thus energy storage density. Due to the negative potential of the iron plating reaction, hydrogen evolution is a main concern in long term operation of the all-iron flow battery. As hydrogen evolves the electrolyte pH will rise, causing precipitation of the ferric ions in the positive electrolyte.This research addresses three critical aspects of the chemistry and design of the all-iron flow battery. First, to increase the ferric ion solubility in relatively high pHs (pH 2 – 3), complexing ligands are considered as an electrolyte additive. Kinetic and mass transfer behavior of several iron-ligand complexes are examined. An electrolyte containing a 0.5:1 glycine to iron ratio showed Fe<sup>3+</sup> solubility at pHs greater than 2.5 and reasonable kinetic performance on a glassy carbon electrode. Modeling of the equilibrium species in an iron-glycine solution is used to design an electrolyte with the desired solubility and concentration of Fe<sup>3+</sup>. Second, the iron deposition reaction is considered in conjunction with added ligand. Further suppression of hydrogen evolution was also considered through the use of various supporting electrolytes. High concentrations of chloride ions were found to hinder hydrogen evolution in the negative electrolyte, both on an iron rod electrode and in an all-iron flow battery. Third, the plating capacity of the negative deposition electrode is considered. Six three dimensional electrode structures are presented, and an achievable plating density of 150 mAh/cm<sup>2</sup> is demonstrated in two separate electrode structures. Cycling of an all-iron flow battery with a voltaic efficiency of 80% is demonstrated."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.177","3.17 MB"]},{"key":"dc:title","label":"Title","values":["Iron-Ligand Electrokinetics towards an all-Iron Hybrid Redox Flow Battery"]}]}],"canonical_facts":{"dc:contributor.advisor":["Savinell, Robert","Wainright, Jesse"],"dc:creator":["Hawthorne, Krista Leigh"],"dc:date":["2014-09-02"],"dc:description":["Flow batteries as a large scale energy storage technology have seen a renewed interest in recent years with the implementation of renewable energy sources on the grid. One such flow battery is the all-iron chemistry. The all-iron flow battery utilizes the Fe II/III redox couple as the positive electrode and the Fe II/0 reaction as the negative electrode. Iron plating in the negative electrode occurs in the cell stack, necessitating intelligent design of the porous electrode structure to maximize plating density, and thus energy storage density. Due to the negative potential of the iron plating reaction, hydrogen evolution is a main concern in long term operation of the all-iron flow battery. As hydrogen evolves the electrolyte pH will rise, causing precipitation of the ferric ions in the positive electrolyte.This research addresses three critical aspects of the chemistry and design of the all-iron flow battery. First, to increase the ferric ion solubility in relatively high pHs (pH 2 – 3), complexing ligands are considered as an electrolyte additive. Kinetic and mass transfer behavior of several iron-ligand complexes are examined. An electrolyte containing a 0.5:1 glycine to iron ratio showed Fe<sup>3+</sup> solubility at pHs greater than 2.5 and reasonable kinetic performance on a glassy carbon electrode. Modeling of the equilibrium species in an iron-glycine solution is used to design an electrolyte with the desired solubility and concentration of Fe<sup>3+</sup>. Second, the iron deposition reaction is considered in conjunction with added ligand. Further suppression of hydrogen evolution was also considered through the use of various supporting electrolytes. High concentrations of chloride ions were found to hinder hydrogen evolution in the negative electrolyte, both on an iron rod electrode and in an all-iron flow battery. Third, the plating capacity of the negative deposition electrode is considered. Six three dimensional electrode structures are presented, and an achievable plating density of 150 mAh/cm<sup>2</sup> is demonstrated in two separate electrode structures. Cycling of an all-iron flow battery with a voltaic efficiency of 80% is demonstrated."],"dc:format":["application/pdf","p.177","3.17 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1405002859"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Chemical Engineering","Energy","Flow Battery","Hybrid Flow Battery","Energy Storage"],"dc:title":["Iron-Ligand Electrokinetics towards an all-Iron Hybrid Redox Flow Battery"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:39:45Z"}