{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1405070015"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1405070015","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Restoring Sensation in Human Upper Extremity Amputees using Chronic Peripheral Nerve Interfaces","abstract":"We restored normal sensation for up to two years in the perceived hands of amputees. The sense of touch is essential to experience and manipulate the world around us. Despite increasingly sophisticated mechatronics, prosthetics still do not convey sensation back to amputees. Sensory perception is important for control of the prosthetic limb, a sense of embodiment, and in the reduction of phantom pain. Those with limb loss rely primarily on visual feedback for control. Chronically-implanted, single-channel nerve cuff electrodes have produced sensation in the perceived hand with perceptions such as fist clenching, vibration, and paresthesia, and sensations was over large regions of the hand. Intrafascicular electrodes have produced discrete, tactile sensation but were only implanted for four weeks or less and paresthesia was associated with 30% - 50% of the stimulating channels. A need exists to provide natural, discrete, tactile sensation in a stable, long-term neural interface. We implanted multi-channel cuff electrodes, the spiral and FINE, on the peripheral nerves of two upper-limb amputees. Discrete, tactile sensory perception was recruited from 97% of the electrode channels. Long-term stability was demonstrated with up to two years of stable stimulation threshold and impedance measures. Stimulation pulse charge and frequency modulated the size of the percept area and intensity, respectively. Moreover, we discovered patterned stimulation intensity elicited natural tactile modalities of pressure, light moving touch, and vibration, while avoiding paresthesia. The functional benefit of sensory feedback was evaluated through functional and activities of daily living (ADL) tests. Sensors mounted on the prosthetic hand provided grip pressure and opening span feedback through sensory stimulation to the subjects. We found sensory feedback improved success rates in blinded object detection, object localization, and controlled pressure manipulation tasks. Performance with sensory feedback while blindfolded was similar to performance while sighted. Results from a standardized ADL test, the Southampton Hand Assessment Procedure (SHAP), show that the sensory feedback does not degrade myoelectric control. Sensory feedback reduces reliance on visual feedback when using prosthesis.","abstract_html":"We restored normal sensation for up to two years in the perceived hands of amputees. The sense of touch is essential to experience and manipulate the world around us. Despite increasingly sophisticated mechatronics, prosthetics still do not convey sensation back to amputees. Sensory perception is important for control of the prosthetic limb, a sense of embodiment, and in the reduction of phantom pain. Those with limb loss rely primarily on visual feedback for control. Chronically-implanted, single-channel nerve cuff electrodes have produced sensation in the perceived hand with perceptions such as fist clenching, vibration, and paresthesia, and sensations was over large regions of the hand. Intrafascicular electrodes have produced discrete, tactile sensation but were only implanted for four weeks or less and paresthesia was associated with 30% - 50% of the stimulating channels. A need exists to provide natural, discrete, tactile sensation in a stable, long-term neural interface. We implanted multi-channel cuff electrodes, the spiral and FINE, on the peripheral nerves of two upper-limb amputees. Discrete, tactile sensory perception was recruited from 97% of the electrode channels. Long-term stability was demonstrated with up to two years of stable stimulation threshold and impedance measures. Stimulation pulse charge and frequency modulated the size of the percept area and intensity, respectively. Moreover, we discovered patterned stimulation intensity elicited natural tactile modalities of pressure, light moving touch, and vibration, while avoiding paresthesia. The functional benefit of sensory feedback was evaluated through functional and activities of daily living (ADL) tests. Sensors mounted on the prosthetic hand provided grip pressure and opening span feedback through sensory stimulation to the subjects. We found sensory feedback improved success rates in blinded object detection, object localization, and controlled pressure manipulation tasks. Performance with sensory feedback while blindfolded was similar to performance while sighted. Results from a standardized ADL test, the Southampton Hand Assessment Procedure (SHAP), show that the sensory feedback does not degrade myoelectric control. Sensory feedback reduces reliance on visual feedback when using prosthesis.","abstract_has_math":false,"creators":["Tan, Daniel"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Tyler, Dustin"],"committee_members":[],"year":2014,"date_issued":"2014-09-02","date_published":"2014-09-02","updated_at":"2026-11-27T04:39:45Z","subjects":["Biomedical Engineering","Biomedical Research","prosthesis, sensory feedback, neural interfaces, neural prosthesis, amputees, neural engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1405070015","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1405070015","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1405070015","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1405070015","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Tyler, Dustin"]},{"key":"dc:creator","label":"Author","values":["Tan, Daniel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-09-02"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Biomedical Research","prosthesis, sensory feedback, neural interfaces, neural prosthesis, amputees, neural engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1405070015"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["We restored normal sensation for up to two years in the perceived hands of amputees. The sense of touch is essential to experience and manipulate the world around us. Despite increasingly sophisticated mechatronics, prosthetics still do not convey sensation back to amputees. Sensory perception is important for control of the prosthetic limb, a sense of embodiment, and in the reduction of phantom pain. Those with limb loss rely primarily on visual feedback for control. Chronically-implanted, single-channel nerve cuff electrodes have produced sensation in the perceived hand with perceptions such as fist clenching, vibration, and paresthesia, and sensations was over large regions of the hand. Intrafascicular electrodes have produced discrete, tactile sensation but were only implanted for four weeks or less and paresthesia was associated with 30% - 50% of the stimulating channels. A need exists to provide natural, discrete, tactile sensation in a stable, long-term neural interface. We implanted multi-channel cuff electrodes, the spiral and FINE, on the peripheral nerves of two upper-limb amputees. Discrete, tactile sensory perception was recruited from 97% of the electrode channels. Long-term stability was demonstrated with up to two years of stable stimulation threshold and impedance measures. Stimulation pulse charge and frequency modulated the size of the percept area and intensity, respectively. Moreover, we discovered patterned stimulation intensity elicited natural tactile modalities of pressure, light moving touch, and vibration, while avoiding paresthesia. The functional benefit of sensory feedback was evaluated through functional and activities of daily living (ADL) tests. Sensors mounted on the prosthetic hand provided grip pressure and opening span feedback through sensory stimulation to the subjects. We found sensory feedback improved success rates in blinded object detection, object localization, and controlled pressure manipulation tasks. Performance with sensory feedback while blindfolded was similar to performance while sighted. Results from a standardized ADL test, the Southampton Hand Assessment Procedure (SHAP), show that the sensory feedback does not degrade myoelectric control. Sensory feedback reduces reliance on visual feedback when using prosthesis."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.156","2.5 MB"]},{"key":"dc:title","label":"Title","values":["Restoring Sensation in Human Upper Extremity Amputees using Chronic Peripheral Nerve Interfaces"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Tyler, Dustin"],"dc:creator":["Tan, Daniel"],"dc:date":["2014-09-02"],"dc:description":["We restored normal sensation for up to two years in the perceived hands of amputees. The sense of touch is essential to experience and manipulate the world around us. Despite increasingly sophisticated mechatronics, prosthetics still do not convey sensation back to amputees. Sensory perception is important for control of the prosthetic limb, a sense of embodiment, and in the reduction of phantom pain. Those with limb loss rely primarily on visual feedback for control. Chronically-implanted, single-channel nerve cuff electrodes have produced sensation in the perceived hand with perceptions such as fist clenching, vibration, and paresthesia, and sensations was over large regions of the hand. Intrafascicular electrodes have produced discrete, tactile sensation but were only implanted for four weeks or less and paresthesia was associated with 30% - 50% of the stimulating channels. A need exists to provide natural, discrete, tactile sensation in a stable, long-term neural interface. We implanted multi-channel cuff electrodes, the spiral and FINE, on the peripheral nerves of two upper-limb amputees. Discrete, tactile sensory perception was recruited from 97% of the electrode channels. Long-term stability was demonstrated with up to two years of stable stimulation threshold and impedance measures. Stimulation pulse charge and frequency modulated the size of the percept area and intensity, respectively. Moreover, we discovered patterned stimulation intensity elicited natural tactile modalities of pressure, light moving touch, and vibration, while avoiding paresthesia. The functional benefit of sensory feedback was evaluated through functional and activities of daily living (ADL) tests. Sensors mounted on the prosthetic hand provided grip pressure and opening span feedback through sensory stimulation to the subjects. We found sensory feedback improved success rates in blinded object detection, object localization, and controlled pressure manipulation tasks. Performance with sensory feedback while blindfolded was similar to performance while sighted. Results from a standardized ADL test, the Southampton Hand Assessment Procedure (SHAP), show that the sensory feedback does not degrade myoelectric control. Sensory feedback reduces reliance on visual feedback when using prosthesis."],"dc:format":["application/pdf","p.156","2.5 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1405070015"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Biomedical Research","prosthesis, sensory feedback, neural interfaces, neural prosthesis, amputees, neural engineering"],"dc:title":["Restoring Sensation in Human Upper Extremity Amputees using Chronic Peripheral Nerve Interfaces"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:39:45Z"}