{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1412786849"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1412786849","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Measuring Perfusion with Magnetic Resonance Imaging using Novel Data Acquisition and Reconstruction Strategies","abstract":"Tissue perfusion is an important metric that can provide valuable information for disease diagnosis, treatment planning, and treatment follow-up. MRI can quantify perfusion both with and without Gd-based contrast agents, and can provide spatially-localized perfusion maps. However, these techniques are rarely used in the clinical environment. The works in this thesis focused on providing novel data acquisition and/or reconstruction techniques to overcome limitations in DCE MRI and ASL in order to provide clinically-viable perfusion exams.There are three main projects that will be described in this thesis. First, a simultaneous 3D magnetic resonance angiography and perfusion (MRAP) exam is proposed and is demonstrated in the distal lower extremities. Second, a 3D non-Cartesian parallel imaging method is described and used to achieve a low-dose, 3D, high spatiotemporal resolution renal DCE MRI exam that is acquired without breath-holding. Finally, a novel approach to ASL is proposed using the Magnetic Resonance Fingerprinting framework to simultaneously quantify perfusion, transit time, and tissue T1 in a single, efficient acquisition.","abstract_html":"Tissue perfusion is an important metric that can provide valuable information for disease diagnosis, treatment planning, and treatment follow-up. MRI can quantify perfusion both with and without Gd-based contrast agents, and can provide spatially-localized perfusion maps. However, these techniques are rarely used in the clinical environment. The works in this thesis focused on providing novel data acquisition and/or reconstruction techniques to overcome limitations in DCE MRI and ASL in order to provide clinically-viable perfusion exams.There are three main projects that will be described in this thesis. First, a simultaneous 3D magnetic resonance angiography and perfusion (MRAP) exam is proposed and is demonstrated in the distal lower extremities. Second, a 3D non-Cartesian parallel imaging method is described and used to achieve a low-dose, 3D, high spatiotemporal resolution renal DCE MRI exam that is acquired without breath-holding. Finally, a novel approach to ASL is proposed using the Magnetic Resonance Fingerprinting framework to simultaneously quantify perfusion, transit time, and tissue T1 in a single, efficient acquisition.","abstract_has_math":false,"creators":["Wright, Katherine L."],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Gulani, Vikas"],"committee_chairs":["Wilson, David"],"committee_members":[],"year":2015,"date_issued":"2015-02-09","date_published":"2015-02-09","updated_at":"2026-11-27T04:39:58Z","subjects":["Biomedical Engineering","Magnetic Resonance Imaging","Perfusion","Dynamic Contrast Enhanced MRI","Arterial Spin Labeling"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1412786849","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1412786849","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1412786849","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1412786849","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gulani, Vikas"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Wilson, David"]},{"key":"dc:creator","label":"Author","values":["Wright, Katherine L."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-02-09"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Magnetic Resonance Imaging","Perfusion","Dynamic Contrast Enhanced MRI","Arterial Spin Labeling"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1412786849"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Tissue perfusion is an important metric that can provide valuable information for disease diagnosis, treatment planning, and treatment follow-up. MRI can quantify perfusion both with and without Gd-based contrast agents, and can provide spatially-localized perfusion maps. However, these techniques are rarely used in the clinical environment. The works in this thesis focused on providing novel data acquisition and/or reconstruction techniques to overcome limitations in DCE MRI and ASL in order to provide clinically-viable perfusion exams.There are three main projects that will be described in this thesis. First, a simultaneous 3D magnetic resonance angiography and perfusion (MRAP) exam is proposed and is demonstrated in the distal lower extremities. Second, a 3D non-Cartesian parallel imaging method is described and used to achieve a low-dose, 3D, high spatiotemporal resolution renal DCE MRI exam that is acquired without breath-holding. Finally, a novel approach to ASL is proposed using the Magnetic Resonance Fingerprinting framework to simultaneously quantify perfusion, transit time, and tissue T1 in a single, efficient acquisition."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.187","6.05 MB"]},{"key":"dc:title","label":"Title","values":["Measuring Perfusion with Magnetic Resonance Imaging using Novel Data Acquisition and Reconstruction Strategies"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gulani, Vikas"],"dc:contributor.committeechair":["Wilson, David"],"dc:creator":["Wright, Katherine L."],"dc:date":["2015-02-09"],"dc:description":["Tissue perfusion is an important metric that can provide valuable information for disease diagnosis, treatment planning, and treatment follow-up. MRI can quantify perfusion both with and without Gd-based contrast agents, and can provide spatially-localized perfusion maps. However, these techniques are rarely used in the clinical environment. The works in this thesis focused on providing novel data acquisition and/or reconstruction techniques to overcome limitations in DCE MRI and ASL in order to provide clinically-viable perfusion exams.There are three main projects that will be described in this thesis. First, a simultaneous 3D magnetic resonance angiography and perfusion (MRAP) exam is proposed and is demonstrated in the distal lower extremities. Second, a 3D non-Cartesian parallel imaging method is described and used to achieve a low-dose, 3D, high spatiotemporal resolution renal DCE MRI exam that is acquired without breath-holding. Finally, a novel approach to ASL is proposed using the Magnetic Resonance Fingerprinting framework to simultaneously quantify perfusion, transit time, and tissue T1 in a single, efficient acquisition."],"dc:format":["application/pdf","p.187","6.05 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1412786849"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Biomedical Engineering","Magnetic Resonance Imaging","Perfusion","Dynamic Contrast Enhanced MRI","Arterial Spin Labeling"],"dc:title":["Measuring Perfusion with Magnetic Resonance Imaging using Novel Data Acquisition and Reconstruction Strategies"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:39:58Z"}