{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1415548044"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1415548044","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Machine Learning Based Analysis of Coronary Stent Images in Intravascular Optical Coherence Tomography Pullbacks","abstract":"Coronary artery disease (CAD) is the most common heart disease and the leading cause of death worldwide. Stent implantation via percutaneous coronary intervention is a popular procedure for treating CAD. Drug eluting stents (DESs) were shown to reduce restenosis compared to bare metal stents. However, DESs were related to a higher risk of late stent thrombosis, a catastrophic clinical event caused by delayed arterial healing. Therefore, it’s important to evaluate the treatment efficacy and safety of new stent designs via pre-clinical and clinical trials. Stent strut coverage and apposition assessed by intravascular optical coherence tomography (IVOCT) have become important metrics for evaluating stent feasibility. Currently, stent analysis in IVOCT pullbacks is primarily done manually, which requires 6~12 hours per stent. The time and labor cost limits the size and efficiency of stent trials. In addition, inter- and intra-observer variability is inevitable in manual analysis, which affects study reproducibility. A fast, accurate, and consistent method for stent analysis is needed.We combined advanced image processing techniques, supervised machine learning algorithms, and a large database of manually analyzed stent pullbacks to develop highly automated software for comprehensive analysis of stent IVOCT images. For stent strut detection, we first detected candidate struts and extracted multiple features from each candidate using image processing. A Bagged Decision Trees classifier was trained on manually annotated images and used to identify true struts from the candidates. To analyze stent tissue coverage, more image features were extracted from several pixel patches around the detected struts. We then trained a Support Vector Machine classifier to classify struts as covered vs. uncovered. A graph-based algorithm, Mesh Growing, was developed to detect clusters of uncovered struts. Stent area, lumen area, tissue coverage area, and strut coverage thickness were automatically quantified. Convenient manual review and editing tools were built in the software. The developed software was applied to a stent study involving ~300 pullbacks. With software assistance, analysis time of a full stent was reduced to 0.5~1 hour and inter-observer agreement was improved. The application of this software to more clinical trials should enable faster, larger, and more reproducible stent studies.","abstract_html":"Coronary artery disease (CAD) is the most common heart disease and the leading cause of death worldwide. Stent implantation via percutaneous coronary intervention is a popular procedure for treating CAD. Drug eluting stents (DESs) were shown to reduce restenosis compared to bare metal stents. However, DESs were related to a higher risk of late stent thrombosis, a catastrophic clinical event caused by delayed arterial healing. Therefore, it’s important to evaluate the treatment efficacy and safety of new stent designs via pre-clinical and clinical trials. Stent strut coverage and apposition assessed by intravascular optical coherence tomography (IVOCT) have become important metrics for evaluating stent feasibility. Currently, stent analysis in IVOCT pullbacks is primarily done manually, which requires 6~12 hours per stent. The time and labor cost limits the size and efficiency of stent trials. In addition, inter- and intra-observer variability is inevitable in manual analysis, which affects study reproducibility. A fast, accurate, and consistent method for stent analysis is needed.We combined advanced image processing techniques, supervised machine learning algorithms, and a large database of manually analyzed stent pullbacks to develop highly automated software for comprehensive analysis of stent IVOCT images. For stent strut detection, we first detected candidate struts and extracted multiple features from each candidate using image processing. A Bagged Decision Trees classifier was trained on manually annotated images and used to identify true struts from the candidates. To analyze stent tissue coverage, more image features were extracted from several pixel patches around the detected struts. We then trained a Support Vector Machine classifier to classify struts as covered vs. uncovered. A graph-based algorithm, Mesh Growing, was developed to detect clusters of uncovered struts. Stent area, lumen area, tissue coverage area, and strut coverage thickness were automatically quantified. Convenient manual review and editing tools were built in the software. The developed software was applied to a stent study involving ~300 pullbacks. With software assistance, analysis time of a full stent was reduced to 0.5~1 hour and inter-observer agreement was improved. The application of this software to more clinical trials should enable faster, larger, and more reproducible stent studies.","abstract_has_math":false,"creators":["Lu, Hong"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Wilson, David"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-02-09","date_published":"2015-02-09","updated_at":"2026-11-27T04:40:02Z","subjects":["Biomedical Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1415548044","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1415548044","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1415548044","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1415548044","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wilson, David"]},{"key":"dc:creator","label":"Author","values":["Lu, Hong"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-02-09"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1415548044"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Coronary artery disease (CAD) is the most common heart disease and the leading cause of death worldwide. Stent implantation via percutaneous coronary intervention is a popular procedure for treating CAD. Drug eluting stents (DESs) were shown to reduce restenosis compared to bare metal stents. However, DESs were related to a higher risk of late stent thrombosis, a catastrophic clinical event caused by delayed arterial healing. Therefore, it’s important to evaluate the treatment efficacy and safety of new stent designs via pre-clinical and clinical trials. Stent strut coverage and apposition assessed by intravascular optical coherence tomography (IVOCT) have become important metrics for evaluating stent feasibility. Currently, stent analysis in IVOCT pullbacks is primarily done manually, which requires 6~12 hours per stent. The time and labor cost limits the size and efficiency of stent trials. In addition, inter- and intra-observer variability is inevitable in manual analysis, which affects study reproducibility. A fast, accurate, and consistent method for stent analysis is needed.We combined advanced image processing techniques, supervised machine learning algorithms, and a large database of manually analyzed stent pullbacks to develop highly automated software for comprehensive analysis of stent IVOCT images. For stent strut detection, we first detected candidate struts and extracted multiple features from each candidate using image processing. A Bagged Decision Trees classifier was trained on manually annotated images and used to identify true struts from the candidates. To analyze stent tissue coverage, more image features were extracted from several pixel patches around the detected struts. We then trained a Support Vector Machine classifier to classify struts as covered vs. uncovered. A graph-based algorithm, Mesh Growing, was developed to detect clusters of uncovered struts. Stent area, lumen area, tissue coverage area, and strut coverage thickness were automatically quantified. Convenient manual review and editing tools were built in the software. The developed software was applied to a stent study involving ~300 pullbacks. With software assistance, analysis time of a full stent was reduced to 0.5~1 hour and inter-observer agreement was improved. The application of this software to more clinical trials should enable faster, larger, and more reproducible stent studies."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.128","2.96 MB"]},{"key":"dc:title","label":"Title","values":["Machine Learning Based Analysis of Coronary Stent Images in Intravascular Optical Coherence Tomography Pullbacks"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wilson, David"],"dc:creator":["Lu, Hong"],"dc:date":["2015-02-09"],"dc:description":["Coronary artery disease (CAD) is the most common heart disease and the leading cause of death worldwide. Stent implantation via percutaneous coronary intervention is a popular procedure for treating CAD. Drug eluting stents (DESs) were shown to reduce restenosis compared to bare metal stents. However, DESs were related to a higher risk of late stent thrombosis, a catastrophic clinical event caused by delayed arterial healing. Therefore, it’s important to evaluate the treatment efficacy and safety of new stent designs via pre-clinical and clinical trials. Stent strut coverage and apposition assessed by intravascular optical coherence tomography (IVOCT) have become important metrics for evaluating stent feasibility. Currently, stent analysis in IVOCT pullbacks is primarily done manually, which requires 6~12 hours per stent. The time and labor cost limits the size and efficiency of stent trials. In addition, inter- and intra-observer variability is inevitable in manual analysis, which affects study reproducibility. A fast, accurate, and consistent method for stent analysis is needed.We combined advanced image processing techniques, supervised machine learning algorithms, and a large database of manually analyzed stent pullbacks to develop highly automated software for comprehensive analysis of stent IVOCT images. For stent strut detection, we first detected candidate struts and extracted multiple features from each candidate using image processing. A Bagged Decision Trees classifier was trained on manually annotated images and used to identify true struts from the candidates. To analyze stent tissue coverage, more image features were extracted from several pixel patches around the detected struts. We then trained a Support Vector Machine classifier to classify struts as covered vs. uncovered. A graph-based algorithm, Mesh Growing, was developed to detect clusters of uncovered struts. Stent area, lumen area, tissue coverage area, and strut coverage thickness were automatically quantified. Convenient manual review and editing tools were built in the software. The developed software was applied to a stent study involving ~300 pullbacks. With software assistance, analysis time of a full stent was reduced to 0.5~1 hour and inter-observer agreement was improved. The application of this software to more clinical trials should enable faster, larger, and more reproducible stent studies."],"dc:format":["application/pdf","p.128","2.96 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1415548044"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering"],"dc:title":["Machine Learning Based Analysis of Coronary Stent Images in Intravascular Optical Coherence Tomography Pullbacks"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:40:02Z"}