{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:case1416583475"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:case1416583475","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"THE DEVELOPMENT AND CHARACTERIZATION OF NON-LINEAR ROUTING WIRE BONDING PROCESS FOR HIGH-DENSITY CUFF ELECTRODE CONNECTOR","abstract":"Implantable interconnect systems have been used in the application of neural interfaces to bridge electrode contacts and larger discrete wires. A robust interconnect system should conduct electrical signals while serving as a mechanical buffer between flexible nerve electrodes and bulky discrete wire bundles near the implantation site. An interconnect system was designed with microwire helices around strain-relief silicone tubing as an alternative approach to discrete in-line connectors and high-density thin film interconnects. Design criteria were designed based on short and long-term mechanical reliability for the device. The helical structure achieves a lower channel resistance compared to thin film traces. In addition, it can withstand short-term mechanical loads as well as 1.2 million cycles of 5% axial strain. This electronic interface can be applied to any implantable electronic system that requires metallic interconnects, which in the future will become useful for the development of human-machine interfaces.","abstract_html":"Implantable interconnect systems have been used in the application of neural interfaces to bridge electrode contacts and larger discrete wires. A robust interconnect system should conduct electrical signals while serving as a mechanical buffer between flexible nerve electrodes and bulky discrete wire bundles near the implantation site. An interconnect system was designed with microwire helices around strain-relief silicone tubing as an alternative approach to discrete in-line connectors and high-density thin film interconnects. Design criteria were designed based on short and long-term mechanical reliability for the device. The helical structure achieves a lower channel resistance compared to thin film traces. In addition, it can withstand short-term mechanical loads as well as 1.2 million cycles of 5% axial strain. This electronic interface can be applied to any implantable electronic system that requires metallic interconnects, which in the future will become useful for the development of human-machine interfaces.","abstract_has_math":false,"creators":["Xu, Yueshuo"],"institution":"Case Western Reserve University School of Graduate Studies","degree_name":"Master of Sciences (Engineering)","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Dustin , Tyler"],"committee_members":[],"year":2015,"date_issued":"2015-02-09","date_published":"2015-02-09","updated_at":"2026-11-27T04:40:02Z","subjects":["Biomedical Engineering","neural implant design","interconnect system","reliability testing"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1416583475","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=case1416583475","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Acase1416583475","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Acase1416583475","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Dustin , Tyler"]},{"key":"dc:creator","label":"Author","values":["Xu, Yueshuo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-02-09"]},{"key":"dc:publisher","label":"Institution","values":["Case Western Reserve University School of Graduate Studies / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Sciences (Engineering)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Case Western Reserve University School of Graduate Studies"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","neural implant design","interconnect system","reliability testing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=case1416583475"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Implantable interconnect systems have been used in the application of neural interfaces to bridge electrode contacts and larger discrete wires. A robust interconnect system should conduct electrical signals while serving as a mechanical buffer between flexible nerve electrodes and bulky discrete wire bundles near the implantation site. An interconnect system was designed with microwire helices around strain-relief silicone tubing as an alternative approach to discrete in-line connectors and high-density thin film interconnects. Design criteria were designed based on short and long-term mechanical reliability for the device. The helical structure achieves a lower channel resistance compared to thin film traces. In addition, it can withstand short-term mechanical loads as well as 1.2 million cycles of 5% axial strain. This electronic interface can be applied to any implantable electronic system that requires metallic interconnects, which in the future will become useful for the development of human-machine interfaces."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.85","7.67 MB"]},{"key":"dc:title","label":"Title","values":["THE DEVELOPMENT AND CHARACTERIZATION OF NON-LINEAR ROUTING WIRE BONDING PROCESS FOR HIGH-DENSITY CUFF ELECTRODE CONNECTOR"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Dustin , Tyler"],"dc:creator":["Xu, Yueshuo"],"dc:date":["2015-02-09"],"dc:description":["Implantable interconnect systems have been used in the application of neural interfaces to bridge electrode contacts and larger discrete wires. A robust interconnect system should conduct electrical signals while serving as a mechanical buffer between flexible nerve electrodes and bulky discrete wire bundles near the implantation site. An interconnect system was designed with microwire helices around strain-relief silicone tubing as an alternative approach to discrete in-line connectors and high-density thin film interconnects. Design criteria were designed based on short and long-term mechanical reliability for the device. The helical structure achieves a lower channel resistance compared to thin film traces. In addition, it can withstand short-term mechanical loads as well as 1.2 million cycles of 5% axial strain. This electronic interface can be applied to any implantable electronic system that requires metallic interconnects, which in the future will become useful for the development of human-machine interfaces."],"dc:format":["application/pdf","p.85","7.67 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=case1416583475"],"dc:language":["English"],"dc:publisher":["Case Western Reserve University School of Graduate Studies / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","neural implant design","interconnect system","reliability testing"],"dc:title":["THE DEVELOPMENT AND CHARACTERIZATION OF NON-LINEAR ROUTING WIRE BONDING PROCESS FOR HIGH-DENSITY CUFF ELECTRODE CONNECTOR"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Sciences (Engineering)"],"thesis:institution_name":["Case Western Reserve University School of Graduate Studies"]},"updated_at":"2026-11-27T04:40:02Z"}